Loading...
HomeMy WebLinkAbout83-1274 - Title 5 Site PlanLEGEND 99- EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. -[�- PROPOSED CONTOUR aD PROPOSED SPOT EL. TH1 TEST HOLE C. 0. PROP. CLEAN OUT ca3 UTILITY POLE 9-b FIRE HYDRANT r NOTE: NOT ALL SYMBOLS MAY APPEAR IN 01 *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY .PORTION OF SEPTIC SYSTEM SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED EXISTING 2 BEDROOM DWELLING; DESIGN ON 3 BEDROOMS ® 110 GPD = 330 GPD & 1 BEDROOM GUEST COTTAGE ® 110 GPD = 110 GPD USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2) = 880 USE A 2000 GAL. DUAL COMPARTMENT SEPTIC TANK & (1) 1000 GAL. PUMP CHAMBER LEACHING: SIDES: 2 (41.5 + 10.25) 1.85 (.74) = 141 GPD BOTTOM 41.5 x 10.25(.74) = 314 GPD TOTAL: 615 S.F. 455 GPD USE (5) INFILTRATOR 3050'S WITH 3' STONE ALL AROUND APPROVED MA DATE BOARD OF HEALTH ryre<Fe F 6 4 � x 25 BENCH MARK -TOP OF 5.26 1- 0' WATER SHUTOFF EL. = 35.4 `�. ' `0�x,�5.96 SYSTEM PROFILE PROVIDE WATERTIGHT (NOT TO SCALE) ACCESS COVERS TO WITHIN 6' OF FIN. GRADE (DWELL) ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. PROVIDE INSPECTION PORT TO WITHIN 3' OF FINAL GRADE 2% SLOPE REOUIREPVER SYSTEM 4'SCH40 PVC PRECAST H-10 PROP. TEE RISERS (TYPJ 4"OSCH40 PVC 2'r PIPES LEVEL 1ST 2' 2" DOUBFE WASHED PEASTONE OR GEOT ILE FABRIC 33.5' 14 *32.5'± 1D• 2000 GAL H-10 TEE Ste' DUAL COMPARTMENT HOUSE 30.0' TEE SE PTC TANx 29.75' a , ; ; SEE DETAIL o ovo°°000pov0 0� 33.0' GAS BAFFLE .: J o 0 o°"Oo°o o° c °oo„o o. 1, g� , a 33.27'8 2 31.0 *32.4 ± o :t COTTAGE "'`' ' `"• ' " H-20 3050 INFILTRATORS 0 0 0 0 0 0 0 0 0 0 o C 000 0p000p0p000p000p0o0a O�OO�O O� 010�0�0�0, 6' CRUSHED STONE OR MECHANICAL 3/4" TO 1 1/2" DOUBLE WASHED STONE COMPACTION. (15.221 [2]) OVERALL DIMENSIONS TO OUTSIDE OF STONE: 41.5' X 10.25' S, { 3+ R SLOPE) (-L% SLOPE) SLOPE) COTTAGE FOUNDATION - 67' DUAL PUMPD' BOX 12' LEACHING ST 4' CHAMBER 60 FACILITY BOTTOM TH-1 26.0' DWELLING 11NO GROUNDWATER FOUND FOUNDATION PROVIDE WATERTIGHT COVERS TO WITHIN 6" OF FINISH GRADE 4"OSCH40 PVC S=1% MIN. 36.96 .23 29.7D' �p" \ \ 53 �q 14L45 29.' \ pg EXISTING 1 BEDROOM COTTAGE 14" COM GAL t �x\5.9�- \ COMPARTMENT ssD x 33 1 14' TEE GALLON �5 74 \ W 1 GAS BAFFLE COMPARTMENT TUF-TITE EF -4 NOTES 1. DATUM IS APPROX. NGVD 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -1Q 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. ; 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING. CESSPOOLS SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. PROP. VENT WITH CHARCOAL FILTER q ? c \ AND BUGSCREEN (FINAL PLACEMENT BY ?3� \ q!g-� \� so 3'Sg3® 7.1 2.8' EFFLUENT FILTER CONTRACTOR WITH HOMEOWNER _ \ O,Q� '� n O' (OR EQUAL) CONSULTATION) \ � o°O B o d o 6 35.53 � � N I o0• pooCa• p W/MOLDED IN GAS i ,.� I ° PUMP DEFLECTOR \\ 1-35.61 TH rn MECHANICAL COMPACTION & 6" STONE (TYP.) 310 CMR 15.228(1) 4.23 \ \ N N 25.19 .76 �35.45 PRO DE J 94.73 I C.O. 2000 GAL H-10 ST- SHOREY 12' X 6.5' OR APPROVED EQUAL 0 36.45 ' T F UND 4' LIQUID LEVEL n 5.46 g +\34.48 roN 0 g �q 41 O(APP OX. LOC ON Y) .28 CP x 30.1 742 11 �x 34.98 \\ I 36 1 35.23 \ \\ 0• -26.12 35.22 P OP. 1000 GAL PUMP I f \� \ AMBER G /530 1 NOTE: SEPTIC SYSTEM FOR GUEST HOUSE APPROX. (AS -BUILT UNCLEAR) CONTRACTOR SHALL CONFIRM SEPTIC TANK AND BUILDING SEWER LINE LOCATIONS PRIOR TO EXCAVATION FOR GARAGE. (GARAGE TO BE 10' MIN. TO SEPTIC TANK). PROP. 24' x 30' / x3520 1134.56 x3 02 x 27.07 NOTE: RESOURCE AREAS SHOWN AS PER SITE PLAN BY DEMAREST-McLELLAN x 4.56 x 35.25 / ENGINEERING, DATED DECEMBER 31, 1993 (REF: SE 83-1274) 5.24 SEWER LINE MUST BE / 34.89 X 51 // C . .1 ik 35 \ SLEEVED FOR 10' EITHER / \ 8 p 1 SIDE OF CROSSING WI .94 \ PROP. 2 COMPARTMENT 2000 GAL ` �k O 0 x Y1 WATERLINE / 34. SEPTIC TANK }I X 3.39`3?u p % 5.10 3 .73 X .95 ? -26.55 306'34.40' // /4.94 x 4.111 x .92 x 35.39 N �p \ 33.48 X 34 0 II 35.16 GRAVEL DRIVE n 00 78 \� F. .78CAR EN 2 0 O 1A 4 / �1 35'06 x 34.83 Q , 4.11 F 33.33 3 56 11 4.04 x .61 x 30.85 1 exist. x 5 Inver x 3. 7 1 11 -x35.08 34.9 GSAR.PORT x '4 32.93 4.58 x _. .22 - - , PROP. WATERTIGHT COVER TO GRADE ' I DECK I N PROVIDE QUICK DISCONNECT FOR PUMP 34.6 Re-route plumbing 34.7 w to exit in crea , x 30.24 / / ALARM AND CONTROL PANEL 70 shown, at indicated 1 0j TO BE INSTALLED INSIDE ALARM TO BE ON - 32' EXIST. 2 BR elevatio . x 31.71 -. ~e/ BUILDING. SEPARATE CIRCUIT FROM PUMP , DWELLING y 3� 33.41 Q TOP FNDN. x 29.85 - / = INV. IN 27.9' EXIST. 3 34.75' I / 1000 GAL. H-10 5/ 2" PRESSURE LINE BEDROOM CUES 63 SLOPE TO DRAIN BACK TO PC HOUSE 500 GAL.+ DECK / FLOAT SWATCH ALARM ON RESERVE 0.25" WEEP: HOLES i SETTINGS: PUMP ON CHECK VALVE I I/ 4" WORKING RANGE 8" MYERS SRM 4 I4" SUBMERSIBLE 4/10 HP PUMP PUMP OFF 8" SYSTEM (OR EQUAL) ss. 1 o00 000 o 0 0000 1 PUMP CHAMBER AREA = 1.611 ACRES PER ASSESSORS (NOT TO SCALE) WATERPROOF/WATERTIGHT I a SOO• NOTE:. BOATHOUSE AT RIVER NOT SHOWN / EXIST. PIER NOT SHOWN 11-052 DATE DANIEL A. OJALA, P.E., P.L.S. LOCUS MAP NOT TO SCALE ASSESSORS MAP $1 PARCEL 36 TEST HOLE LOGS ENGINEER: ARNE H. OJALA, PE, SE WITNESS: AMY VON HONE, RS DATE: 4/6/11 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS 4 ELEV. 0" 1 36.0' 0/A LS 3" 1OYR 3/2 LS 1OYR 5/6 30" 33.5' C PERC MS 2.5Y 6/6 120" 26_0' NO GROUNDWATER ENCOUNTERED TITLE 5 SITE PLAN OF 30 THIMBLEBERRY LANE SOUTH YARMOUTH PREPARED FOR STEVEN BRANDER APRIL 8, 2011 MAY 18, 2011 (MOVE ST AND PC) REV. 4/26/12 (P -GAR.) Scale: 1"= 20' 0 10 20 30 40 50 FEET I off 508-362-4541 fax 508-362-9880 downcope.com t7oIWO cape engineering, inc. Civil engineers land surveyors . 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 ,•,In