Loading...
HomeMy WebLinkAbout83-1337 - Site PlanAssEssoxs MAP: 24 TEST HOLE LOGS NOTES: PARCEL. 1701 1. VERTICAL DATUM. NGVD d CURRENT ZONING: R-25 ENGINEER: THOMAS McLELLAN, P.E. �, 2B 2. MUNICAPAL WATER IS AVAILABLE. BUILDING SETBACKS: WITNESS: AMY VON HONE, R.S. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. F: 30' S: - 15' R: 22CT DATE. _ '7-12-95 4. ALL PRECAST UNITS TO CONFORM WITH AASHTO ' H-10 tD MILL PERCOLATION RATE. < 2 MIN/IN `a,�e LL Sir LOADING' SPECIFICATIONS. C�nFLOOD ZONE: Aft EL 12), B 8c C TH-1 TH-2 5. PIPE PITCH = 1/4" PER FOOT, (UNLESS NOTED OTHERWISE). 19.0 n,0 6. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. LOCUS ELEV ELEV 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE A HORIZON A HORIZON jr LOAMY SAND 18.2 g" LOAMY SAND 162 USE OF A GARBAGE DISPOSAL. LEWrs FAY B HORIZON B HORIZON 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE LOAMY SAND LOAMY SAND STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL LOCATION MAP 24" 2SY 6/8 17D z4" 2.5Y 6/8 15.0 LOT 1 (54,464 SF) HEALTH REGULATIONS. Cl HORIZON Cl HORIZON 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR MEDIUM SAND MEDIUM SAND TO CONSTRUCTION. Emycia4RK TO WITH GRAVEL WITH GRAVEL CONCRETE MO. 54' 2� 5/6 14s zSY 7/6 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO ELEV- 17.6* oo c2 HORIZON EXCEED 3.0'. A-28,, z 7M FINE SAND 11. D -BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. 1sz" 8.0 1sz" 6.0 12. DESIGN ENGINEER TO INSPECT AND CERTIFY SEPTIC SYSTEM NO GROUNDWATER ENCOUNTERED CONSTRUCTION. SEPTIC SYSTEM DESIGN TH-1 jc / .FLOW ESTIMATE: ro I `% , ♦ � WORK LIMIT LINE 4 BEDROOMS AT 110 GAL/DAY/BEDROOM = 440 CAL/DAY MIN _1 ' / f' . `• ✓� L� (DOUBLE STAKED HAY BALES) m �., '/ ♦♦♦ SEPTIC TANK: 440 GAL/DAY x 2 DAYS = 880 CAL �TH-z f - ` r f p USE 1500 GALLON SEPTIC TANK LEACHING AREA: _ O DIRT DRIVE / /� '� 1 ,' ��,'9,'. , i ,� , , \ y� USE 2 LEACH TRENCHES (42' z 3' x 2' DEEP) SIDE AREA (42 + 3)2 x 2 = 180 SF (-f = 133 GAL/DAY Yg$EDytNG20`� t' ' s4 ; , 11- �� �� BOTTOM AREA: 42 x 3 = 126 SF (.74) = 93 GAL/DAY ; , \o, TRENCH CAPACITY = 226 CAL/DAY •' :' ,' ,' , i '♦ AGS x 2 TRENCHES = 452 GAL/DAY ' ' t � 1 I .' is I•' / i f / , \ S ` C' `--------- - EPT Tr -Y.0 " T F Aif _C PrT Tn AT 20S �A �cP f ''1 f' f',/,�,,', `♦ TOP OF FOUNDATION < COASTAL BANK ---------- ----- it BORDERING ♦ ` VEGETATED ` y , WETLAND 6' �� •^f' /, `` EDGE OF MARSH >qLp %I -Z17.5 , --------ELEV. EXISTING PIER ♦ `\+� ;' f �_ , t,r KEY: EXISTING CONTOUR: PROPOSED CONTOUR. . ...... „' cfL EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION: 25 ' TEST HOLE: UTILITY POLE: -0- FENCE LINE:— HYDRANT: -6- RETAINING l} RETAINING WALL: TREE: DEMAREST-McLELLAN ENGINEERING '24 SCHOOL STREET P.O. BOX 463 DM # 94-117_(D1OF20) WEST DENNIS, MASSACHUSETTS 02870 COVERS WITHIN 12" OF FINISHED GRADE ONE INSPECTION COVER 0 BE WITHIN 6" OF GRADE) 2" PEASTONE 3/4" - 1 1/2" WASHED STONE 4" PERFORATED PVC PIPE ELEV.= 16.15 17.05 --------------- 7.3 1500 GAL ELEV. D -BOX 2' 13.65 15.98 ELEV. ELEV. SEPTIC TANK 16.15 (6" OF ELEV. E 4'2' (6" OF STONE UNDER) ELEV. STONE TWO LEACH TRENCHES UNDER) 15.86 (42' x 3' x 2' DEEP) TEE SIZES: INLET: 6" UP, 13" DOWN ELEV. (MIN DISTANCE BETWEEN TRENCHES = 9') OUTLET. 6" UP, 14" DOWN APPROVED BY: DATE: vdlTHOMAS McLELLAN, P.E. ILLOHN Z. DEMAREST JR., P.L.S. SrJMFA I i�[ll"IINIW�f LOCATION LOT 1 PRINCE ROAD WEST YARMOUTH MA PREPARED FOR- ABRAHAM ORABRAHAM JOSELOW SCALE: 1" = 40' DATE. 7-12-95 REFERENCE: PLAN BOOK 512 PAGE 76 REVISED: 1-29-98 tip, as^; 4 vdlTHOMAS McLELLAN, P.E. ILLOHN Z. DEMAREST JR., P.L.S. SrJMFA I i�[ll"IINIW�f LOCATION LOT 1 PRINCE ROAD WEST YARMOUTH MA PREPARED FOR- ABRAHAM ORABRAHAM JOSELOW SCALE: 1" = 40' DATE. 7-12-95 REFERENCE: PLAN BOOK 512 PAGE 76 REVISED: 1-29-98