Loading...
HomeMy WebLinkAbout83-1377 - Sewage Disposal002DEPTH FROM SURFACE SOIL HORIZON SOIL TEXTURE SOIL COLOR (MUNSELL) SOIL MOTTLING OTHER c. - 10" Af 100 0%-207. 200 0%-5% 0" - 10 A LOAMY SAND 7.5YR 2.5/1 10" - 30" B LOAMY SAND 10YR 5/4 MEDIUM TO 30" - 101" C SAND 1 OYR 6/3 NONE COARSE SAN -NUI DEPTH FROM SOIL SOIL SOIL COLOR SOIL OTHER IS THE MAXHE S OBSERVED FROM MONITOR WELLS ON SITE. AT THE S. ALL NLE INSTALLATION - � � � - — — — — SURFACE HORIZON TEXTURE (MUNSELL) MOTTLING EDGE OF THE SEA MOTEL AND AT THE ADJACENT RMERA MOTEL. STAINLESS STEEL. 0" - 60 Af FILL 7. AN ELECTRICAL PERMIT WILL BE REQUIRED FOR PUMP LEGEND EXISTING AND CONTROL INSTALLATION.. 4' 0 SCH. 40 PERF, PVC PIPE— � - - - - _, 60" - 72" A LOAMY SAND 10YR 4/2 f? MANHOLE (1 CAL - _. �•��-- EXISTING CONTOUR - C 10YR 6 3 NONE MEDIUM TO Y � PRWOSEla PROPOSED CONTOUR 72 124 SAND / COARSE SAN — '�3° VENT GROUNDWATER ENCOUNTERED NOTE — — — _.. — — — — ` EXISTING SPOT GRADES AT A DEPTH OF 83". EL. 3.2 EXISTINo _w. OL SFA n' w. SYSTEM # I SERVES 9 UNITS PROPOSED SPOT GRADE DRAINAGE SYSTEM O 1 y, LEACHING FIELD # I , 2 a 3 - 36 THRU 41 (DOES NOT DN TO WETLAND) ti} EXISTING RAI';�, Cfi CONCRETE RETAINING '# 2 SERVES 22 UNITS WATER SUPPLY LINE VHF--- DESIGN CALCULATIONS -� f WALL. µ � `, � (FACE of WALL IS COASTAL BANK) # 3 SERVES 14 UNITS ' n `{ # 4 SERVES 18 UMTS DESIGN FLAW: 9 BEDROOMS AT 1 10 GAL. PER DAY PER BEDROOM = 990 GPD U N P N D k.� 4., , � t LEACHING FIELD D ETAI L f` y / LElIdIIHC 1000±. S.F. OFFICE AT 75 GPD/1000 S.F. = 75 GPD y ; : ' a a TOTAL DESIGN FLOW = �Pp lk 0IvsCALE' — '� 0'} A 44' L. X 18 W. LEACHING FIELD CAN LEACH: r DRIv>waY.�Zf `r' ��/f PROPOSfD_UPGRADE Vt - 44 { 18 ) x .74 = 586 GPD PER FIELD Vt = 1,172 GPD FOR TWO FIELDS ', WILL SERVE $ tiKITS AND YALVE�i zo ,: ; r ` 1006±�S-:F.-0F,_0FF1tE NOTE. VAULT 100 YEAR FLOOD EL. — 10.0 INSTALL: TWO ( 2 ) - 44 L. x 18'.W. x 0.5 D. LEACHING FIELDS Vt = 1 ,172 GPD ,► -' _ --r ONE ( 1 ) — 2000 GALLON PUMP CHAMBER EDGE OF CENTER INCH MIARIC Wi±TLAND 4 E)i]STiNG`� , f�` FIRST STEP " `- r J C4 T1 TWO 2 - DISTRIBUTION BOXES ( 9 OUTLET) (H-20) '+ :S � x /SEPM TANx ` ` EL. • 12.21- __ _ " - _ - 84SIIi�'� `-r PROPOSED ONE 1 — 2500 GAL. SEPTIC TANK GALLON °°K VENT TO ��.� _� r gEp�t� XI TING ( ) i1'rxJM!' CRAMMER ;r,k f f f _ _f S TLM NOTE' CAPACITY OF EXISTING SEPTIC TANK IS BASED UPON RECORD ` `��"; ' .RQ�os>:D, r - _ - H BE VERIFIED AT TIME PRI�POSm r ;:J,,'l�% " DIST.xI r INFORMATION. CAPACITY AND ADEQUACY OF TEES SHALL , -o• �.- OF CONSTRUCTION. (SEE,D G FIELD ,,; # >' 3�s" CVAMFER (B -S. (SEE DETAIL) -- L LPIPE R,VL�`' ,� ` ! )', / f % / r` ,'off' •1- ti TOP OF MOL,. � �� NOTES EL * 9.o CORES"� sL� as'f r CRAW1'FACE r �� � � ! � - __ S ! _ FOR PPE POST . F .' j` I �� C SYSr FIN °RADE SET IN EPpxl' ; _, IS'* _� -.-' !�, r,_ f,, l�/' �� .• - �.`. .�. --�. •" EM J f" 7 r"` -� •r - 1} GARBAGE GRINDERS ARE NOT ALLOWED WITH THIS DESIGN. 4012' VERT 4 - _ 40 ►ILL. + I r i` / ! –� THE INSTALLER 15 RESPONSIBLE FOR ASSURING THAT COMPONENTS OF POLwNYL se[ S 2) BAitRIE1i f 3 i 11 THE SEWAGE DISPOSAL SYSTEM ARE DESIGNED WITH SUFFICIENT �� i°* r �� f STRENGTH TO SUSTAIN ALL LOADS TO BE IMPOSED ON THEM. ANY SOUTH i4 0 12 NORTH i I32 / f '' + `' ! r i ' '- SEP JI'_ SY �; 1 COMPONENT OF THE SYSTEM SUBJECT TO VEHICULAR TRAFFIC MUST / f ` i /`fXI i - STERy ' ARD OF A A S,H.T.O. H-20 WHEEL LOADS. w ' f i ST RtS' f ; f : + _ _ _- , COMPLY WITH A .MINIMUM STAND a fl / f $Q� f • , r � � �} # 4 � l N SEWAGE DISPOSAL SYSTEM COMPONENT. - x f / f ^ /� r�uj�b! '' r /f ` ' ;' I R - H 1 3) PRIOR TO SETTING ANY S N NT. INSTALLER E' 2 y` !� f f CONDITIONS, INCLUDING ELEVATIONS OF EXIT INVERTS. vE7tT 'f' � BQrC SHALL VERIFY EXISTING CO /I//// �r* To R / SIN 1 1 AND REPORT ANY DISCREPANCIES TO THE DESIGN ENGINEER, PROPOSED ° ! GRAVITY SEWER PIPE SHALL BE 4" DIA. SCH 40 PVC UNLESS OTHERWISEOMPA= nLL REINFORCED r f �.- i �: ! ,' f` ' �= f F f. 1f1 f, 8 ~ ��'�•�� 4) ALL G ab• CONCRETE WALL urnJrr / fr i : �' .' ✓ ,' ; ;' r' . ; NOTED. THE MINIMUM SLOPE OF 4" DIA. SCH 40 PVC SHALL BE 0.01 FT/F7.2.4 1 t A L BE ALTERED WITHOUT PRIOR APPROVAL _6• POL J f ' 1 ,,f' / f `, i i f ✓ 1 / 5} NO PART OF THIS DESIGN SHL 3 #5 FROM THE. DESIGN ENGINEER AND THE AGENT OF THE LOCAL BOARD OF EXNG r E MADE IN WRITING PRIOR CONCRETE WALL A } / `' �` ' i �' �✓ / r L REQUESTS FOR CHANGES SHALL B � FT HEALTH, ALL i r r' / TO CONSTRUCTION. ii s o tz' ,►+�z'-o' a 12' D.C. APPROX. LOCATION r r ` i` ` f ' , ' I { LIMIT OF 1b0 YEAR OF EXISTTNG WATER SERVICE. ,r j ', fF' s' , r; ^ r ! _ 0 6} THE USE OF ALTERNATE MANUFACTURERS FOR SYSTEM COMPONENTS t----s-a`�--� FLOOD EL 10 - M1 SHALL NOT BE APPROVED IF THE USE OF THEIR EQUIPMENT REQUIRES f.�f! CHANGES IN DESIGN. 1 THE INSTALLER SHALL ASCERTAIN THE LOCATION OF EXISTING UNDERGROUND UTILITIES PRIOR (NO saLE) � E TO EXCAVATION, AND SHALL PROTECT UTILITIES WITHIN THE THE WORK AREA DURING CONSTRUCTION. 1 i f' .'/ r ,• �. ,'�,.� DEC/( 8) THE EXISTING EXISTING LEACHING FACILITY TO BE REPLACED SHALL BE REMOVED y'f ` AMI ATED SOILS AND BACKFILLED WITH CLEAN PLAN,. WITH SURROUNDING CONT N SLABCOARSE SAND. CSC VARIANCES REQUIRE (MAXIMUM FEASIBLE COMPLIANCE) IF APPLICABLE: - - — (SCALE: 1 " — 30') 9) FILL MATERIAL FOR SYSTEMS CONSTRUCTED IN FILL SHALL BE CLEAN 310 CMR: 15,403 -LOCAL UPGRADEAPPR V GRANULAR SAND, FREE OF ORGANIC MATTER AND OTHER DELETERIOUS MATERIALS. THE SAND SHALL BE GRADED SUCH THAT NOT MORE THAN 1. REDUCE THE REQUIRED GROUNDWATER SEPARATION SOIL REMOVAL NOTE 45% OF THE SAMPLE. BY WEIGHT, SHALL BE RETAINED ON THE #4 SIEVE. OF 5' DOWN TO 4' THE FILL SHALL NOT CONTAIN ANY MATERIAL LARGER THAN 2 INCHES, WITHIN~} 5' OF PROPOSED, SOIL ABSORPTION SYSTEMS REMAOVE 2" 5wL w4AI, � � SHALL MEET THE 2, REDUCE THE REQUIRED SEPARATION OF 50' BETWEEN ALL MATERIAL DOWN TO THE NATURALLY OCCURING SAND ('C`) � STRATUM�,3 TO 7 FEET BELOW GRADE) AND REPLACE WITH CLEANS FOLLOWING GRADATION REQUIREMENTS: A ^^0kC-fAI nAAl1/ AI.If1 I CAnUIKI(_ C'A(%II ITf noWM TO I I' T., ntA-n^bl a rnI UAT5701M Cue•I UrVT THF SPFrJ(ATIQNS SIEVE PERCENT SIZE PASSING 4 1009: 50 10%-100 100 0%-207. 200 0%-5% TOP OF FOUNDATION EL = EXISTING _ 1 e