Loading...
HomeMy WebLinkAbout83-1409 - Site & Sewage PlanROUTE 28 7zz""_LOCUS LOCATION MAP 4 ASSESSORS MAP. 12 PARCEL: D118 FLOOD ZONE: A 12 EL 12) PROPOSED PAVED DRIVE ---\ (PAVEMENT TO BE PITCHED TOWARD FRONT YARD AND STREET TO PREVENT RUN-OFF FROM FLOWING TO WETLAND) WORK LIMIT LINE SEE NOTE 16 EXISTING SEPTIC SYSTEM (SEE NOTE #12) FIRST FLOOR OF EXISTING DUELLING TO BE RAISED TO ELEVATION 122 TOP OF COASTAL BANK EDGE OF WETLAND DM REQUIRED TITLE FIVE VARIANCES f. SECTION 15211 (1). LEACHING AREA TO BE LESS THAN 10' FROM PROPERTY LINES, (8'). REQUIRED YARMOUTH VARIANCES 1. LEACHING AREA TO BE LESS THAN 100' FROM WETLAND, (50'). EAS PT COSYST ANCE BEEN DESIGNED TO MAXIMUM N TOTAL AREA 24,814 + S.F. (0.57± AC.) �' . fro �d�Ad � • + �( If od 0 4.0:. EXISTING RETAINING WALL, ELEV. - 6.5 HYDRANT DEMAREST-McLELLAN ENGINEERING 24 SCHOOL STREET P.O. BOX 463 WEST DENNIS, MASSACHUSETTS 02670 PHONE A: FAX : (508) 398-7710 DM # 96-056 (D18F26F) A/ 4 �` • III=111=WWI= ELEV I I� 4 MIL POLY 5.5' 3' �--- ASPHALTIC SEALING as 01 ELEV =III=WII • 12" y 1.o I' • �, ELEV 3 PROPOSED CONCRETE RETAINING WALL REINFORCING STEEL: (D.- f4018"o/c ®:#4036"o% d :4 ea #4 ®: J4 0 12"01c NOTE: ALL PEAT IS TO BE REMOVED UNDER FOOTINGS. AREA TO BE COMPACTED WITH BACKHOE PRIOR TO CONSTRUCTION. N3 4.5 Ile .4 PROPOSED WATER LINE BENCHMARK AT PK NAIL ELEV.- 3.42 KEY: EXISTING CONTOUR: - PROPOSED CONTOUR: ............................... EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION. 25 TEST HOLE. UTILITY POLE: -0- FENCE LINE: .HYDRANT: -6 RETAINING WALL. TEST HOLE LOGS ENGINEER: THOMAS McLELLAN, P.E. WITNESS. RON CADILLAC, R.S. DATE: 6-21-96 PERCOLATION RATE: < 2 MINE IN (.74) = TH-1 4 BOTTOM AREA: 50' x-11' = 550 SF (74) = 3.4 GAL/DAY FILL = ELEV 36" SAND & LOAM 0.4 A HORIZON PEAT 48" 2.5Y 2.5/1 , _OB E HORIZON FINE SAND 60" 2.5Y 7/1 -1.6 B HORIZON LOAMY SAND 78' fOYR 3/3 -3.1 TOTAL AREA 24,814 + S.F. (0.57± AC.) �' . fro �d�Ad � • + �( If od 0 4.0:. EXISTING RETAINING WALL, ELEV. - 6.5 HYDRANT DEMAREST-McLELLAN ENGINEERING 24 SCHOOL STREET P.O. BOX 463 WEST DENNIS, MASSACHUSETTS 02670 PHONE A: FAX : (508) 398-7710 DM # 96-056 (D18F26F) A/ 4 �` • III=111=WWI= ELEV I I� 4 MIL POLY 5.5' 3' �--- ASPHALTIC SEALING as 01 ELEV =III=WII • 12" y 1.o I' • �, ELEV 3 PROPOSED CONCRETE RETAINING WALL REINFORCING STEEL: (D.- f4018"o/c ®:#4036"o% d :4 ea #4 ®: J4 0 12"01c NOTE: ALL PEAT IS TO BE REMOVED UNDER FOOTINGS. AREA TO BE COMPACTED WITH BACKHOE PRIOR TO CONSTRUCTION. N3 4.5 Ile .4 PROPOSED WATER LINE BENCHMARK AT PK NAIL ELEV.- 3.42 KEY: EXISTING CONTOUR: - PROPOSED CONTOUR: ............................... EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION. 25 TEST HOLE. UTILITY POLE: -0- FENCE LINE: .HYDRANT: -6 RETAINING WALL. TEST HOLE LOGS ENGINEER: THOMAS McLELLAN, P.E. WITNESS. RON CADILLAC, R.S. DATE: 6-21-96 PERCOLATION RATE: < 2 MINE IN (.74) = TH-1 GAL/DAY BOTTOM AREA: 50' x-11' = 550 SF (74) = 3.4 GAL/DAY FILL = ELEV 36" SAND & LOAM 0.4 A HORIZON PEAT 48" 2.5Y 2.5/1 _OB E HORIZON FINE SAND 60" 2.5Y 7/1 -1.6 B HORIZON LOAMY SAND 78' fOYR 3/3 -3.1 C HORIZON FINE SAND tss" 2.5Y 5/4 -8 6 SEPTIC SYSTEM DESIGN FLOW ESTIMATE: -4- BEDROOMS AT 110 GAL/DAY/BEDROOM =-:L4-0 GAL/DAY SEPTIC TANK. _440 GAL/DAY x 2 DAYS = 880 GAL USE 1500 GALLON SEPTIC TANK LEACHING AREA: USE 6 STANDARD INFILTRATORS WITH 4' OF STONE AROUND SIDES AND _3'_AT ENDS (50' x 1r x 7" DEEP) SIDE AREA. (50 + 11)2 x 7" = 71 SF (.74) = 53 GAL/DAY BOTTOM AREA: 50' x-11' = 550 SF (74) = 407 GAL/DAY TOTAL CAPACITY = 460 GAL/DAY SEPTIC SYSTEM SECTION 12.2 �ROPOSED FIRST FLOOR NOTES: 1. VERTICAL DATUM. NGVD 2. MUNICAPAL WATER IS AVAILABLE. S. SCHEDULE 40 - 4" PPC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS TO CONFORM WITH AASHTO H-10 LOADING SPECIFICATIONS. 5. PIPE PITCH = 1/8'_ PER FOOT, (UNLESS NOTED OTHERWISE). S. FIRST 2' OF PIPE OUT OF D -BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED 3.0. f1. D --BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. 12. EXISTING SEPTIC TANK TO BE PUMPED AND FILLED WITH SAND OR REMOVED. EXISTING LEACH AREA TO BE LOCATED AT TIME OF CONSTRUCTION. LEACH PITS OR SIMILAR STRUCTURES ARE TO BE PUMPED AND FILLED WITH SAND OR REMOVED, LEACH FIELD OR TRENCHES ARE TO BE ABANDONED. f3. DESIGN ENGINEER TO PERFORM THE FOLLOWING INSPECTIONS: A. REMOVAL AND REPLACEMENT OF SOILS. B. STAKE LOCATION OF RETAINING WALL. C. INSPECT FOOTING LOCATION AND REBAR PRIOR TO POURING WALL. D. INSPECT WALL HEIGHT AND LOCATION. E. INSPECT INSTALLATION OF SEPTIC SYSTEM COMPONENTS. 14. ALL UNSUITABLE SOIL (PEAT AND B HORIZON, APPROX. 78" DEEP) TO BE REMOVED WITHIN 5' OF LEACHING AREA AND REPLACED WITH CLEAN MEDIUM SAND. 15. ROOF RUN-OFF TO BE DIRECTED TO DRY WELLS. 16. WORK LIMIT LINE TO BE DOUBLE STAKED HAY BALES OR SILT FENCE. 17. ALL DISTURBED AREAS TO BE REVEGETATED OR MULCHED UPON COMPLETION OF PROJECT. COVERS WITHIN 12" OF FINISHED GRADE ONE INSPECTION COVER 0 BE WITHIN 6" OF GRADE) 6'59 _1500- GAL ELEV. SEPTIC TANK 7A ELEV. (6" OF STONE UNDER OR 6.34 ELEV. (6"OF 6.1 6'22ID-BOX STONE ELEV. ELEV, UNDER MECHANICALLY COMPACTED) TEE SIZES: GAS BAFFLE AT INLET: 6" UP, 13" DOWN OUTLET TEE OUTLET: 6" UP, 14" DOWN APPROVED BY: DATE: THOMAS McLELLAN, P.E. { I JOHN Z. DEMAREST JR., P.L.S. ELEV. GARAGE UNDER FPROP PROP. ADD. DECK EXISTING 4 BEDROOM DWELLING f0' 1st FLK- 7.5 710' PROP. DECK EXISTING & PROPOSED DrELLING 2" PEASTONE 3/4" - 1 1/2" WASHED STONE ,.,-- ELEV = 6.4 5.4 3, ELEV. 50' 5' 6 STANDARD INFILTRATORS WITH 4' OF STONE AROUND SIDES AND X AT ENDS (50' x 11' x 7" EFF. DEPTH) GROUNDWATER ELEV.= 0.4 k_AJ SITE AND SEWAGE PLAN .LOCA TION 5 NEW HAMPSHIRE AVENUE WEST YARMOUTH, MA PREPARED FOR: JOSEPH & LENORE FLANAGAN SCALE: I"= 30' REFERENCE: DATE: 8-7--96 PLAN BOOK 25 PAGE 49 REVISED: 6-3-97 REVISED: 6-11-97