HomeMy WebLinkAbout17 Point of Rocks Road Residence Details1'-5" 10" Pool Walls d 4.Q d 20'-0" v. 0 12" Tread 0I —4'4" 10' i. —4'3" 10 18" Bench 1" Pitch to Main Drains n O d /LED Light /LED Light _ d '` q 4 ad 4:w as 102-0 NOTE: Measurements are from TOP of beam. Subtract 3" for water height - -4 Water Height 10" Rise 1" Pitch to Main Drains77 '�- f3 ® 12" O.C. E.W. Vertically Through Out Entire Pool Walls #4 ® 12" O.C. E.W. Horizontally Through Oat Entire Pool Walls I 8" Pool Floor 4'-4" #3 ® 12" O.C. Shallow End Floor To Deep End Floor Within 18" Of Pool Beam Hydrostatic Relief Valve Install Per Manufacturer's Specifications #4 @ 12" D.C. E.W. Horizontally Through Out Entire Poo Floor 1. All construction is to conform to the Massachusetts state building code, and all applicable product .and design standards. Absence of specific items from these drawings does not infer that the contractor is relieved from the statutory code requirements. 2. All materials and methods of construction shall conform to the approved rules and standards for materials, tests, and requirements of accepted engineering practice as listed in Appendix A of the Massachusetts State Building Code. POOL NOTES: 1. Assume maximum safe soil bearing pressure- 2,000 ressure-2,000 2. All pools are to be paced on natural, .undisturbed material or compacted granular fill. Subsoil bearing strata shall be free from all vegetation, loam, and organic material. 3. Do not place backfill against pool walls. until all walls have obtained 7 day cure strength. 4. All pool floors shall be placed on a 18" layer of crushed stone, compacted to 95% standard proctor density at the optimum moisture content. SHOTCRETE NOTES: 1. Shotcrete mixture, form—work, delivery, placement, and reinforcement shall conform .to all requirements of ACI 506.2795 (latest edition); unless otherwise noted. 2. Concrete materials .shall be: ASTM C Type 1 Portland .Cement. S d dGI t hllb Iweiht UH an rave aggrega es s a e norma g and conform to ASTM C33 Standards. Aggregate not meeting ASTM C33 Standards may be used provided pre construction tests demonstrates the shotcrete can meet specified requirements. All concrete shall be air—entrained. Concrete compressive strength, (f'c) in 28 days. All concrete work— 5,000 psi. NOTE: ELEVATIONS ON EQUIPMENT AND SOUND PROOFING IN ACCORDANCE WITH FLOOD ZONE REGULATIONS— TO BE DETERMINED. REVIEWED FOR BUILDING AND ZONING CODE COMPLI- ANCE. ERRORS OR OMMISSIONS DO NOT RELIEVE THE APPLICANT FROM THE RESPONSIBILITY OF "AS BUILT' COMPLIANCE.pp DATE: BUILDING OFFI IAL FILE COPS'. .