HomeMy WebLinkAbout83-1453 - Septic System 002GENERAL NOTES: SYS TEEM 18.5 I. THIS PLAN 1S FOR THE DESIGN AND CONSTRUCTION / VE. MAP OF THE SEWAGE DISPOSAL SYSTEM ONLY. 2. VERTICAL DATUM IS NGVD. FOR BENCH MARKS SET. SEE SITE PLAN. J. ALL CONSTRUCTION METHODS AND MATERIALS AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.F.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 OR APPROVED EQUAL. 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE AND WATERTIGHT. 7. BEFORE CONSTRUCTION CALL -DIG -SAFE'. 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UTILITIES. S. ALL UNSUITABLE MATERIAL IA 6 B HORIZONS) ENCOUNTERED BELOW THE INVERT OF THE LEACHING FACILITY TO BE REMOVED FOR A DISTANCE OF 5' AROUND AND REPLACED WITH SAND IN ACCORDANCE WITH TITLE S. 9. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEED RESTRICTIONS OR ZONING REGULATIONS. IT SHALL REMAIN THE CLIENTS RESPONSIBILITY TO OBTAIN ALL PERMITS. SPECIAL PERMITS. VARIANCES ETC. FOR THIS PROJECT. �� av► s /0. ANY RETAINING WALL SHOWN ON THIS PLAN IS FOR LOCATION ONLY AND SHALL BE DESIGNED IN ACCORDANCE WITH STANDARD PRACTICE. / 11. IT SHALL REMAIN THE CLIENT'S RESPONSIBILITY TO HAVE THE PROPOSED BUILDING FOUNDATION ovra1 DESIGNED TO ACCOUNT FOR THE EXISTING GRADE AND SOIL CONDITIONS AT THE LOCATION OF THE PROPOSED BUILDING. 12. SEPTIC SYSTEM INSTALLER SHALL NOTIFY THE DESIGN ENGINEER TWO DAYS PRIOR TO CONSTRUCTION OF THE SYSTEM TO ALLOW FOR SCHEDULING OF THE CONSTRUCTION INSPECTIONS. INSPECTIONS SHALL BE AS FOLLOWS: •1. ENGINEER SHALL INSPECT WHEN THE REQUIRED EXCAVATION IS COMPLETE. ro.9s *2. ENGINEER SHALL INSPECT WHEN THE FILL HAS BEEN PROPERLY PLACED. +3. ENGINEER SHALL STAKE THE PROPOSED LEACH FIELD PRIOR TO PLACEMENT. •4. ENGINEER SHALL INSPECT WHEN THE COMPONENTS OF THE SEPTIC SYSTEM HAVE BEEN INSTALLED. 13. INSTALLATION OF FAST UNIT TO BE CERTIFIED B'Y FAST REPRESENTATIVE. A YEARLY INSPECTION AND MAINTENANCE CONTRACT SHALL BE MAINTAINED WITH THE FAST REPRESENTATIVE. 14. THIS LOT FALLS WITHIN FLOOD ZONES C AND P AS SHOWN ON FEMA COMMUNITY PANEL NO. 250015 004 C DATED 6/17/86. 15. ROOF RUNOFF TO BE DIRECTED TO DRYWELLS OR A STONE TRENCH ALONG THE DRIP LINE. VARIANCES REQUIRED: TITLE 5 SECTION 15.248. RESERVE AREA A VARIANCE IS REQUESTED TO NOT SHOW A SEPARATE RESERVE AREA BUT TO REMOVE AND REPLACE THE LEACHING SYSTEM IN THE PRIMARY AREA IN THE EVENT OF A FAILURE. TOWN OF YARMOUTH HEALTH REGULATION SECTION 3.7. DISTANCES 100' IS REQUIRED BETWEEN THE SAS AND THE WETLANDS. 60' AND 75' ARE PROPOSED. 40' AND 25' VARIANCES ARE REQUESTED, ACCESS COVERS MUST BE TO FINISH GRADE - VENT BLOWER n pie, MIN FAST LNn r 9' MINIMUM. FIRST 2' TO 4'PERF PVC SCHED 40 MIN. 2' OF BE LEVEL 7 16.2 MIN / / (' 2x _PEAS TONE TOP WALL 15.4 MIN 3O'x 10' LEACH 3 OUTLET FIELD aoT tact u.4 MAX Y500 D -BOX b 3/4' - 1 1/2' DIA. GAL WASHED STONE H-20 SEPTIC TANK 6' CRUSHED STONE BASE FAST READY ADJ Or - 9.24 WATERTIGHT AND Lv oeJ or . 6.94 FACTORY WATERPROOFED INDEX WELL TSW e9. ZONE A PROFILE : NOT TO SCALE NOVEVBER 1990 ADJ-2.3• 12. DESIGN CRITERIA: DESIGN FLOW: 2 BEDROOMS AT 110 G.P.D. PER BEDROOM EQUALS 220 G.P.D. NO GARBAGE GRINDER SEPTIC TANK REQUIRED: 220 G.P.D. X 2002 - 440 GAL. SEPTIC TANK PROVIDED: 1500 GAL. MIN. SOIL ABSORPTION SYSTEM REQUIRED: DESIGN PERC RATE l 5 MIN/INCH SOIL TEXTURAL CLASS - I EFFLUENT LOADING RATE - 0.74 GPD/SF 220 GPD / 0.74 GPD/SF - 298 S.F. REQUIRED PROVIDED: 10'x 30' LEACH FIELD, 6' DEEP A - 300 S.F. x 0.74 GPD/SF - 222 GPD en , RIM 12.57 q� +12.2 avr's _ ,ti RIM - 12.27 �8M Ce/DH V /ryy, EL -12.45 evr 3 TBW/ \ { F > + 1: 13, <114 � -f/J.o 1 / FAST 107 N` 1 500 eat •� SEPTIC C F\ ♦ �_ �� D -00X TANK i �+. FILL O 13.36 t• 6 i ) i r O ♦ Y ,C,. \\ I?rw 10 �'9c +10.6 // 9.7 t t Y +�-JOIE REMOVAL, SEE NOTE a �\p...►�' • _:;J. \ s'F / LEACH . 12.7 1,qf\yl \ �F�y YW 9 FIELD BM CB/DH EL -14.11 avW e FILL \J 1\ \(3318= S.F. Ja" i r . nJ \ 10.0 TOP OF WATER 7/30/97 uam 2 EL e.o 10.0 9.0 /• G p4`v N SOIL TEST PIT DA TA e INDICATES INDICATES PERCOLATION = OBSERVED TEST GROUNDWATER TP +2A TP *3A 0'12.94 O' 12.94 SAND LOAN FILL 508501E 12' ........... 11.94 is. . ........... 11.44 LoaM SUBSOIL 24' ............ 10.94 COARSE COARSE SAND SAND 72'-* 16.94 72'-tt 16.94 2.94 76' t 16.61 DATE: DECEMBER 6. 1990 TEST BY: C. YOUNG. DOWN CAPE WITNESSED BY: DAVE MASON. BOH PERC RATE: ! 2 MIN/INCH LOCUS MAP SEPT/C SYS TEEM OE -S /G/V 300 LO/VG POND OR / VE. MAP 52. PARCEL A / 7 SOUTH YAR"OUTH, AWA PREPARED FOR : MRS. GOROO/V G/q RO / NER 0/0 L O/VG POND DR / VE. SOUTH YARMOUTH. /VIA . SCALE: / - 20 MAY S. /998 REVISED: SEPTEMBER 16. 1998 EAGLE SURVEYING, INC 923 Route 6A / Yarmouthport, MA. 02675 (508) 362-8132 ( 508 ) 432-5333