Loading...
HomeMy WebLinkAbout83-1460 - Site & Sewage Disposal PlanSEPTIC PROFILE -� ACCESS COVER. TO WITHIN C OF FIN. GRADE (NOT TO SCALE) ACCESS COVER (WATERTIGHT) TO MINIMUM J5' OF COVER OVER PRECAST WITHIN G OF FlN. GRADE 27 SLOPE REQUIRED OVER SYS7EJ 10.75' rCULTEC FILTER FABRIC FER SPECS �l 10.0' 2 ii U 1111111114 i._ "g 9.35' CULTEC C4 FIELD DRNIN PANELS r 3/4" TO 1 1/2" DOUBT`- `HASHED STONNE1 5. 10' _ LEACHING FACILITY PROPOSED 1500 GALLON SEPTIC TANK (H- 20 ) -OW s 4- TH = 10" =PTH = 14" 1DATION- 26.5' 'UIR£O AROUND /COS LAYER. RUN PIPE LEVEL FOR FIRST 2' 10.18' BAFFLE�� \ 9,-- 76 9.93' CRUSHED STONE OR MECHANICAL IPACTION. (15.221 {2]) ( 1 %SLOPE) ( 7, SLOPE) SEPTIC TANK HIGH POINT �/ 5• 45' C 5 RES \ �/ \ TH 2 \ TH1 i 72' \ GAR '"'o- 10 �, \ SLAB UN0;STi BUFFER 25 D' BOX BENCHMARK - TOP OF CONC. BND. EL= 11.28 (NGVD) ABUTT. HSE. \ ,L \ PROP. 3 BR \ Lj \ mv? W v .� BY,ELL. 12 T.F. = 13.4 r � 86' X35' _7 51' t SFT 9\ �6 52' ti0 50' DMPLIANCE" JLES FOR 3ACK TO LEACH FACILITY TO BE 86' TO ARIANCE REO.) RESERVE TO BE 72' TO THE VCE REQ.) (SEE NOTE BELOW) FAIL, PLACE EACH SYSTEM. PROB. SEPTIC SYSTEM AREA ADJUSTED WATER EL. 4.35' WELL: MIW 29 ZONE: A ADJ: 0.4' TOP OF FNDN IS 3.4' ABOVE THE HIGH POINT 1141 -4 11 f vAD \ � js 9.4 x DECK 9.0 8.6 PROP. SILT FENCE BACKED BY HAYBALES Lor 17A Arec = 42,270± sq.ft. 0.97 Acres 601 or6s ) TEST HOLE LOGS ENGINEER: D.A. OJALA, SE WITNESS: AMY VON HONE, RS DATE: 5/28/98 PERC. RATE _ < 2 MIN PER INCH CLASS I & (II SOILS P# N/A CT ELEV. w 0" 10.2' 0 0 2" 2,. AID AID LS LS 7" 10YR 4/2 7" 10YR 4/2 B 8 LS LS 28" 10YR 6/8 7.4' 28" 10YR 6/8 7.9' Cl C1 MED/COS MED/COS 69" 7 jobs. water 13.95 84"V obs. water 3.2' 114„ 2.5Y 6/6 0.7' 2. 5Y fi/6 108" ., 120" C2 C2 SILT LOAM SILT LOAM 2.5Y 7/2 2.5Y 7/2 126" SEPTIC DESIGN: (GARBAGE DISPOSER Is NOT ALLOWED DESIGN FLOW: 3 BEDROOMS ( 110 GPD) = 330 GPD 1ISr. A 330 GPn OFSI-N FLOW SEPTIC TANK: 330 GPD ( 2 ) = 660 USE A 1-500 GALLON SEPTIC TANK LEACHING: SIDES: N/A BOTTOM:26 x 18 (.74) = 346 TOTAL: 468 S.F. 346 GPD USE LEACH FIELD OF 2 ROWS OF (3) C4 CULTEC FIELD DRAIN PANELS, WITH 4' OF STONE BETWEEN ROWS 3' .AT SIDES AND 1' .AT ENDS LEGEND 100.0 PROPOSED SPOT ELEVATION 100X0 EXISTING SPOT ELEVATION `` .100 PROPOSED CONTOUR - - 100- - EXISTING CONTOUR ,I?, PROP. DRYWELL BOARD OF HEALTH APPROVED DATE off 508-362-4541 fax 508 362-9880 down cape engineering, inc. CIVIL ENGINEERS LAND SURVEYORS 939 main st. yarmouth, ma 02675 MA -0.45 I EnfTE2 Y w fv�yS ' � 1 zn i LOCATION MAP SCALE 1" ASSESSORS MAP 13 PARCEL 017-1 ZONING DISTRICT: R-25 YARD SETBACKS: FRONT = 30' SIDE = 6' REAR = 20' PLAN REF. - 56/9 1925 FLOOD ZONE: A ELEV. 10.0' NOTES: 1. DATUM IS NGVD 2. MUNICIPAL WATER IS .AVAILABLE 10 3, MINIMUM PIPE P17CH TO BE -1/8" /8" PER FOOT. & 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 20 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. rr1 ;rlvnnl�acNTa.L CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING, 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. WATER TEST D'BOX FOR LEVELNESS. SITE AND SEWAGE PLAN OF #86 CROWELL ROAD IN THE TOWN OF: (WEST) YARMOUTH PREPARED FOR: MICHAEL DENARO 30 0 30 60 90 SCALE: 1 - 30 DATE: SEPTEMBER 18, 1998 ARM£ H. CUALA CIVIL Na 30792 ARNE H. OJALA No. 26348 H. OJALA, P.E., REV. 10/13/98 lo�i5�g� DATE