Loading...
HomeMy WebLinkAboutReview Checklist � fi-� �z �/;� TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST � Location: A.M.�_ Lot� Zone of Contribution: In Out �Acreage �' Commercial: Residential:/ � ' Street: �j' //� ; Village: Floor Plan: ✓ #Bedrooms:�_ , o��: J,� �S�ll�: �(��u� �/a�•G��� Address: Phone: � Phone: i � i Builder: Engineer: � Address: Phone: � Phone: , l N/A YES NO 1.Re uired#of copies received 2. Date of soils exam and ercolation test not older than 2 years 3.4-5 ft of naturall occurrin ervious material, above water table 4.Foundation 2 ft above hi oint of road H.P.: Fnd: Var.: 5. Water line 10 ft from septic com onents Var.: �.,r 6.Benchmark indicated and shown-NGVD if near wetlands 7. Se tic tank minimum 10 ft from foundation, deck Var.: 8.Leachin minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: �� 9.Leaching minimum 100 ft from wetlands Var.: �_ 10.Leaching minimum 150 ft from drinkin welU25 ft irrigation well Va.r.: 11. Tank/leaching minimum 10 ft from property line Var.: � -..� 12. S stem meets all other setback r uirements Var.: 13.Uses adjustment for maximum hi groundwater Var.: 14.Leaching set 4-5 ft above ad'. water or bottom of test hole Var.: L�� 15. System not in to or subsoil(A,B horizons)or 5'removal �_,..- 16.Pro osed contours are suitable �� 17. S stem meets slo e r uirements-min. 1/8", '/4" referred � 18. S stem meets breakout r uirements PVC liner: Wall: �-- 19. Specified tee sizes are ro er, as baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel ,�,/ 21.No garba e disposal ��,,, 22. S stem ad ua.tel sized for its intended use , 23.Minimum 6"stone or compacted below tank and dbox • 24.Manhole covers within 6"of grade, ump chamber cover to grade � 25.Ins ection ort on lastic chambers/leach field � .. 26.Elecirical ermit for um cha.mber/S a.rate meter for du lexes 27.Pum system-2"line,wee hole,check valve,tee in dbo�pum size 28. S tic tank/ ump chamber to be factory wat roofed 29.Vent rovided if leaching below 3 feet, under driveway/parking 30.Buoyanc calculations for tank/ um chamber 31.En ' eer to ins ect and cerf soils: wall: commerciaL ' 32.Engineer/Registered Sanitarian and Land Surveyor stam s/signature 33.H-201oadin is subject to vehicular traffic, oundwater ' 34.Title V A lication a.nd ermit fee, installer signature 35.Foundaxion footing min. 2 feet above ad'usted ound water for new house 36.Deed Restriction r uired max. #bedrooms: max. flow: d 37.Check area lots for oundwater/Label groundwater in Assessor's Ma Plan reviewed by: ��;, W03/03 i