HomeMy WebLinkAboutReview Checklist � --�--�� TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST • Zone of Contribution: In Out `� Acreage Location: A.M.�_ Lot Z�� . _ _ ; %���'�% Commercial: Residential: �� Street: � G / Village: Floor Plan: ✓ #Bedrooms: -s"�.,�/��,' .�i�' j c6� '.; � Jr Owner: �/I �� Insta.11er: Address: Phone: � � -�,�p� � Phone: _ �r� � ���������. `s'}�'�� ; Builder: Engineer: � Address: Phone: 4 '-" '� Phone: .�-C� �� '��� -7� .���'�, �, �f�.. , � f' , -- "� ��' ' �'C�'�� �G�' ��' ,��� N/A NO � 1.Required#of co ies received 2.Date of soils exam and ercolation test not older than 2 years �.�- 3.4-5 ft of naturall occurrin ervious material,above water table �.�- 4.Foundation 2 ft above hi oint of road H.P.: Fnd: Var.: 5.Water line 10 ft from s tic com onents Var.: �_--- 6.Benchmark indicated and shown-NGVD if near wetlands 7. S tic tank minimum 10 ft from foundation, deck Var.: �---� 8.Leachin minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9.Leaching minimum 100 ft from wetlands Var.: � 10.Leaching minimum 150 ft from drinking we1U25 ft irri tion well Var.: 1 l.Tank/leaching minimum 10 ft from ro e line Var.: �` 12. S stem meets all other setback r uirements Var.: 13.Uses adjustment for maximum high oundwater Var.: 14.Leachin set 4-5 ft above adj.water or bottom o s o ; Var.: 15. System not in to or subsoil(A,B horizons)0 5'rem 16.Pro osed contours are suitable �' 17. S stem meets slo e r uirements-min. 1/8", '/a" referred 18. System meets breakout r irements PVC liner: all: 19. S ecified tee sizes are ro er, s baffle on outlet tee (./'J� 20. Sewa e is under 10,000 gpd for arcel 21.No arbage dis osal �---�� 22. S stem ad ua.tel sized for its intended use � 23.Minimum 6"stone or com acted below tank and dbox 24.Manhole covers within 6"of ade, um chamber cover to grade 25.Ins ection ort on lastic chambers/leach field 26.Electrical ermit for um chamber/S arate meter for du lexes 27.Pum system-2" line,weep hole,check valve,tee in dbox,pum size �--�' 28.S tic tank/ ump chamber to be facto waterproofed �--- 29.Vent rovided if leaching below 3 feet,under driveway/ arkin ✓ 30.Buo anc calculations for tank/ u chamber 31.En ' eer to ins ect and cert' soils: wall: commercial: 32.Engineer/Registered Sanitaria.n and Land Surve or sta.m s/si ture ' 33.H-201oadin is subject to vehicular trai�c, groundwater 34.Title V A lication and ermit fee, insta.11er si ture 35.Foundation footing min. 2 feet above adjusted ound water for new house 36.Deed Restriction r uired max. #bedrooms: max.flow: d 37.Check area lots for oundwater/Label groundwater in Assessor's M ` Plan reviewed by: � '� 6/03/03