HomeMy WebLinkAboutReview Checklist I . � - j�o ��1� --��` ;
7 ` TOWN OF YARMOUTH .� '
' SEWAGE PLAN REVIEW CHECKLIST •���!�'', � ✓`���'��� i
_ Location: A.M. � � Lot 2 � V Zone of Contribution: In `� Out_ Acreage � (d �- ��
, � -
� Commercial: Residential:
Street:
Village: Floor Plan: #Bedrooms:_�
Owner: /'�i�{�I _/�itQG!'� ���°G� Installer: � �
Address: Phone: � - Z �
Phone:
Builder: Engineer: G�
Address: Phone: "� -- -
Phone: '
N/A YES NO
1.R uired#of copies received
2.Date of soils exam and ercolation test not older than 2 years �---�'
3.4-5 ft of naturall occurrin ervious material, above water table
4.Foundation 2 ft above high int of road H.P.: Fnd: Var.:
5.Water line 10 ft from septic com onents Var.:
6.Benchmark indicated and shown-NGVD if near wetlands
7. S tic tank minimum 10 ft from foundation, deck Var.:
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: ��
9.Leaching minimum 100 ft from wetlands Var.:
10.Leaching minimum 150 ft from drinkin welU25 ft irri tion well Var.:
11.Tank/leaching minixnum 10 ft from roperty line
Var.
12. S stem meets all other setback r uirements Vaz.:
13.Uses adjustment for maximum high oundwater Var.:
14.Leachin set 4-5 ft above adj.water or bottom of test hole Var.:
15. S stem not in to or subsoil(A,B horizons)or 5'removal ��
16.Pro osed contours are suitable '
17. S stem meets slo e r uirements-min. 1/8", '/4" referred .
18. S stem meets breakout r uirements PVC liner: Wall: `�� '
19. S ec�ed tee sizes are pro er, as baffle on outlet tee
20. Sewage is under 10,000 d for arcel �--/ '
, 21.No ba e disposal L-/�
22. S stem ad uatel sized for its intended use i_..---�
23.Minimum 6"stone or com acted below tank and dbox �---
� 24.Manhole covers within 6"of grade, ump chamber cover to grade �/
25. Ins ion ort on lastic chambers/leach field L�
26.Electrical ermit for um chamber/S arate meter for du lexes �;.----
27.Pump system-2" line,wee hole,check valve,tee in dbo�pump size �'"
28. S tic tank/ um chamber to be facto wat roofed
29.Vent rovided if leachin below 3 feet,under drivewa / arking
� 30.Buoyancy calculations for tank/pum chamber
� 31.En ' eer to ins ect and cert' soils: wall: commercial:
32.En ' eer/Re 'stered Sanitarian and Land Surve or s/si ature �---�-�'
33.H-201oadin is subject to vehicular traffic, oundwater ---'
34.Title V A lication and ermit fee, installer si ture
35.Foundation footing min. 2 feet above ad'usted ound water for new house .�-
36.Deed Restriction r uired max. #bedrooms: max. flow: d -�
37.Check area lots for groundwater/Label oundwater in Assessor's
� Plan reviewed by: � -� �,osio3
.
�
i
I