Loading...
HomeMy WebLinkAboutEngineered Plan - 2016I PROPOSED CONTOUR ® PROPOSED SPOT GRADE --98-- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE W— EXISTING WATER SERVICE TEST PIT �t C Z 39.0 "- 4n n I jEP: 500G j TANK Ao.o O 1s' 39.G CP 33.10' — 1 L4.0 I' "n 39.0 Q) O 11' o ==j !:r 11.32 N SHED 38.7 38.9 7 Survey by. Weller & Assoc. AREA=0.35 ACRES WATER_ 5ERVICE '1- S-tC- °0) o O0 mo N m J o O ------------------------ DRIVEWAY Q �J N LOCUS 45 GREEN WAY noG o 3 0 <G L m a 0 N Ng CEIVED JUL 1 1 2016 HEALTH DEPT. LOCUS MAP LOCUS INFORMATION TITLE REF: BK 28083 PG 125 PARCEL ID: MAP 090 PAR. 065 Yarmouth Health Department PPR VED ame Date BED BED RM RM BATH BED RM LIV RM DIN RM KIT GAR FLOOR PLAN SCALE: 1"=20' SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 45 GREEN WAY SOUTH YARMOUTH, MA PREPARED FOR MESSIER/CALDWELL JULY 7, 2016 OF Algss9�y� DARREN M. YE �R._/ No #140 MEYER & SONS, INC. P.O. BOX 981 EAST SANDWICH, MA. 02537 PH: (508)360-3311 FAX: (774)413-9468 meyerandsonstitle54gmail.com www.meyerandsons.com SHEET 1 OF 2 J#1744 NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS T.O.F. EL.=40.0± SEPTIC TANK PROPOSED D -BOX INSTALL RISERS & COVERS OVER INLET & INSTALL RISER & COVER OUTLET AND SET TO 6" OF FINISH GRADE SET TO 6" OF GRADE `-F.G. EL.=39.50± /- F.G. EL.=39.50f /--F.G. EL: 39.30± 9MIN COVER/ 36' MAX COVER j L = 25' 0 S=1% (MIN.)EL 37.80 0 S=1% (MIN.) 4"SCH40 PVC 4"SCH40 PVC to' INV.=36.75 14 48` UWID LEVEL �INV.=36,50 GAS BAFFLE INV.=36.20 PROPOSED 1.500 GALLON SEPTIC TANK EXIST. SEWER OUTLET INV.=37.75 1 INV.=37.75 NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION 2) TANK/D-BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2) 3) INSTALL INLET & OUTLET TEES W/ GAS BAFFLE AS REQUIRED DESIGN CRITERIA L - 10'(MAX) 0 S=1% (MIN.) 4"SCH40 PVC 11.3" TO INVERT INV.=35.81 - BREAKOUT=TOP ELEV.= 36.20 INV. ELEV.= 35.81 BOTTOM ELEV.= 34.87 NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL: 36.20 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. PROPOSED S.A.S. INSTALL A 4" DIAMETER INSPECTION PORT OVER ONE CHAMBER (MIN.) AND SET TO 3" OF F.G. TF.G. EL: 39.2 (MAX.).. 5' MIN. ABOVE BOTTOM OF T.P. EXCAVATION OR G.W. (6.82' PROVIDED) BOTTOM OF TESTHOLE: EL:28.05 SEPTIC SYSTEM PROFILE N.T.S. NUMBER OF BEDROOMS: 3 BEDROOM DESIGN DESIGN FLOW: RESIDENTIAL: 3 BEDROOMS 0 110 GPD/BR = 330 GPD DESIGN PERCOLATION RATE: <2 MIN/IN SOIL TEXTURAL CLASS: CLASS 1 (0.74 GPD/SF) GARBAGE GRINDER: NO (not designed for garbage grinder) DISTRIBUTION BOX: USE DB -5 (H20) SEPTIC TANK: 330 gpd x 200% = 660 gpd USE PROP. 1,50OG SEPTIC TANK LEACHING AREA REQUIRED: (330)/.74 = 445.94 S.F. PRIMARY S.A.S. USE 4 ROWS OF 4 - HI -CAP INFILTRATOR H-20 UNITS -NO STONE BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.73 SF/LF OF CHAMBER) (CHAMBER) 16 UNITS x 6.25 LF x 4.73 SF/LF = 473.0 SF TOTAL AREA = 473 SF DESIGN FLOW PROVIDED: 0.74GPD/SF(473SF) = 350 GPD > 330 GPD req'd \\ INSTALL TWO INSPECTION PORTS (MIN.) 4 ROWS OF 4 UNITS AT 6.25'/UNIT = 25'/ROW SOIL ABSORPTION SYSTEM (PROFILE) 2.83' RESTORE VEGETATIVE COVER PERC SAND EXISTING SUITABLE MATERIAL EFFECTIVE WIDTH = 4 x 2.83' = 11.321 USE 4 ROWS OF 4 -HIGH CAPACITY INFILTRATOR (H20) UNITS W/ ENDCAP-NO STONE DA�RNRt-�)"No. 1140 Al R R� TYPICAL SECTION N.TS SOIL LOGS DATE: JUNE 22, 2016 SOIL EVALUATOR: DARREN M. MEYER, CSE 1614 WITNESS: A. VONHONE, YARMOUTH HEALTH GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V. AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. DWELLING IS SERVICED BY MUNICIPAL WATER SUPPLY. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO STARTING WORK. 10. EXISTING LEACHING TO BE PUMPED, CRUSHED AND REMOVED PER TITLE 5. REPLACE WITH CLEAN MEDIUM SAND PER TITLE 5 REQUIREMENTS. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY UNE SURVEY 13. NO KNOWN PRIVATE WELLS WITHIN 100 FT. OF PROPOSED LEACHING 14. ALL PIPING TO BE 4" SCH 40 0 1/8"/FT (UNLESS SPEC. ) 15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER. 16. NO WETLANDS WITHIN 150 FT. OF PROPOSED LEACHING Elev. TP- 1 Depth 39.05 A 0" LOAMY SANG 16' tOYR 4/1 38.23 B 10" LOOAMY SAND �. 0YR 6/6 36.23 C 34' SECTION 11, MEDIUM INVERT EIGHEND CAP 2.5Y 7/4 INFILTRATOR - HI CAPACITY (H2O) CHAMBER PROPOSED SEPTIC SYSTEM UPGRADE PLAN 28.05 132" 45 GREEN WAY, SOUTH YARMOUTH, MA PERC RATE <2 MIN/IN. ("Cl* HORIZON) NO GROUNDWATER OBSERVED Prepared for: Messier/Caldwell System Design and Site Plan by: SCALE MEYER & SONS, INC. N.T.S. • I, Darren M. Meyer, R.S., CSE, hereby certify that I am currently approved by MADEP pursuant to 310 CMR 15.017 POSOX981 to conduct soil evaluations and that the above analysis has been performed by me consistent with the E4STSANDMCH,M402537 REV DATE requirements of 310 CMR 15.017. 1 further certify that 1 have passed the Soil Evol. Exam in October, 1999. 508382 zsz2 DRAWN DATE DMM 07/07/16 CHECKED SHEET NO. DMM 2 of 2