Loading...
HomeMy WebLinkAboutReview Checklist ��-Z-� -�6 // /"'� � / r/J�-� TOWN OF YARMOUTH �a� ��'C rG._ �t7"�-f✓.�"� � SEWAGE PLAN REVIEW CHECKLIST ; Location: A.M. /Qr Lot / �o Zone ofContribution: In ut�creage Commercial: Residential:�� Street: A��'/ Village: yg0 Floor Plan: � #Bedrooms: � .�f � Owner: �L�l'�SG' /%',��GZ�1/J Installer: �,/ Address: Phone: g � l - Phone: Builder: Engineer: � / Address: Phone: � �- Z Phone: N/A YES NO l.R uired#of copies received 2.Date of soils exam and ercolation test not older than 2 years �- 3.4-5 ft of na.turall occurrin ervious material,above water ta.ble �� 4.Foundation 2 ft above high oint of road H.P.: Fnd: Var.: � 5. Water line 10 ft from s tic com onents Var.: 6.Benchmark indicated and shown-NGVD if near wetlands 7. S tic tank minimum 10 ft from foundation, deck Var.: �,,.-� 8.Leachin minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9.Leachin minimum 100 ft from wetlands Var.: 10.Leaching minimum 150 ft from drinkin welU25 ft irrigation well Var.: ��--'�"" 11.Tank/leaching minimum 10 ft from property line Var.: 12. S stem meets all other setback r uirements Var.: 13.Uses ad'ustment for maximum hi oundwater Var.: 14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.: ..�� 15. System not in to or subsoil(A,B horizons)or 5'removal 16.Pro sed contours aze suitable 17. S stem meets slo e r irements-min. 1/8", '/4" referred 18. S stem meets breakout requirements PVC liner: Wall: �--� ' 19. S ecified tee sizes are ro er, as baffle on outlet tee �.�- 20. Sewa e is under 10,000 d€or arcel , 21.No arba e dis osal 22.S stem ad uatel sized for its intended use 23.Minimum 6"stone or com acted below tank and dbox ' 24.Manhole covers within 6"of ade, um cha.mber cover to grade 25.Ins ection ort on la.stic chambers/leach field �1 26.Electrical ermit for um chaxnber/S arate meter for du lexes ""'-"A 27.Pump system-2" line,wee hole,check valve,tee in dboa�, ump size 28.Septic tank/ um chamber to be facto wat roofed 29.Vent rovided if leaching below 3 feet,under driveway/parking 30.Buo anc calcula.tions for tank/ u chamber 31.En ' eer to ins ect and cert' soils: wall: commercial: 32.En ' eer/Re ' ered Sanitarian and Land Surveyor stam s/si ture 33.H-201oading is subject to vehicular traffc, oundwater 34.Title V A lication and ermit fee, installer si ature 35.Foundation footin min. 2 fe�t above ad'usted ground water for new house " 36.Deed Restriction r uired max. #bedrooms: max. flow: 37.Check area lots for oundwater/Label oundwater in Assessor's Ma Plan reviewed by: C�`'� 6/03/03