Loading...
HomeMy WebLinkAboutReview Checklist, �� �/�� TOWN OF YARMOUTH ��� '�� i 4 SEWAGE PLAN REVIEW CHECKLIST ���'. � /���'� Location: A.M. r6 Lot�_ Zone of Contribution: In � Acreage /���/� ��"� ' � Commercial: Residential: �--� Street: Village: !� Floor Plan: c�J #Bedrooms:�"� Owner:�G �r.��Z�('��_ Insta.11er: � Address: Phone: Phone: Builder: Engineer: �� Address: Phone: �- � Phone: - ���� ��Ci z`T�,e�,,�'�,� N/A YES NO 1.Required#of copies received �.� 2. Date of soils exam and ercolation test not older than 2 ears --�"� 3. 4-5 ft of naturall occurrin ervious material, above water table 4.Foundation 2 ft above hi oint of road H.P.: Fnd: Var.: 5. Water line 10 ft from septic com onents Var.: �, 6.Benchmark indicated and shown-NGVD if near wetlands ti----�' 7. Se tic tank minimum 10 ft from foundation, deck Var.: �..� 8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: ;ii 9.Leaching minimum 100 ft from wetlands Var.: �---- . 10.Leachin minimum 150 ft from drinking welU25 ft irrigation well Var.: 11. Tank/leaching minimum 10 ft from pro erty line Var.: .�-'° 12. S stem meets all other setback r uirements Var.: �_,.�� 13.Uses ad'ustment for maximum high groundwater Var.: " 14.Leachin set 4-5 ft above adj.water or bottom of test hole Var.: j____,.... 15. S stem not in to or subsoil(A.,B horizons)or 5'removal 16.Pro osed contours are suitable �y= 17. S stem meets slo e r uirements-min. 1/8", '/4" eferred 18. S stem meets breakout requirements PVC liner: a1L• 19. S ec�ed tee sizes are ro er, as ba.ffle on outlet tee L..r-- 20. Sewage is under 10,000 gpd for parcel . 21.No garba e dis osal 22.S stem ad uatel sized for its intended use 23.Mmimum 6"stone or compacted below tank and dbox �,y. i 24.Manhole covers within 6"of grade, um cha.mber cover to grade �w 25.Inspection port on lastic chambers/leach field 26.Electrical ermit for um chamber/S arate meter for du lexes 27.Pum system-2" line,wee hole,check valve,tee in dbo�pum size - 28. Septic tank/pump chamber to be factory wat roofed 29.Vent rovided if leaching below3 feet,under driveway/ arkin 30.Buoyancy calculations for tank/pum cha.mber -�' 31.En ' eer to ins ect and cert' soils: wall: commerciaL 32.Engineer/Registered Sanitarian and Land Surveyor stam s/signature 33.H-201oading is subject to vehicular traffic, oundwater ' 34.Title V A plication and ermit fee, insta.11er si ture 35.Foundation footing min. 2 feet above ad'usted ground water for new house -� 36.Deed Restriction r uired max. #bedrooms: maac. flow: d 37. Check area lots for groundwater/Label oundwater in Assessor's M Plan reviewed by: � �io3io3