Loading...
HomeMy WebLinkAboutEngineered Plan - 2003» N AT ELI 18.4' PROVIDE IF NECESSARY SYSTEM P R FF 1 L E TOP, FN DNI ACCESS COVER TO WITHIN 6" OF FIN. GRADE (NOT TO SCALE) J ACCESS COVER (WATERTIGHT) TO MINIMUM .75' OF COVER OVER PRECAST /� WITHIN 6" OF FIN. GRADE 2% SLOPE REQUIRED OVER SYSTEM 2" DOUBLE WASHED PEASTO ELI 16.75' RUN PIPE LEVEL ;. FOR FIRST 2' NE EXISTING 1000 GALLON SEPTIC LANK (RE -USED) GAS �� El 14.17' 0 14 O O O O O O O O ( BAFFL 14.34 •0' OOOO O OOOO ' OOOL Cl OOOO 6" CRUSHED STONE OR MECHANICAL 2' O O O O C7 O O O O i� COMPACTION. (15.221 [2)) DEPTH OF FLOW = 4'(4 y SLOPE) ( 1 y SLOPE) 3/4" TO 1 1/2" DOUBLE WASHED STOLE TEE SIZES: INLET DEPTH 10"•: OUTLET DEPTH - 14" FOUNDATION--- EXIST. SEPTIC TANK 25' D' BOX 19' LEACHIN•, FACILITY *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL SEPTIC. DESIGN: (GARWE DISPOSER tS NOT ALLOWED ) BUILDING SEWER OUTLETS AND ELEVATIONS DESIGN FLOW: 4- BEDROOMS (110 GPD) 440 GPD PRIOR TO INSTALLING ANY PORTION OF USE A 440 GPD DESIGN FLOW SEPTIC SYSTEM, EPTIC TANK: 440 GPD ( 2 ) 880 RE—USE 1000 GALLON SEPTIC TANK SIDES: 2(44.5 + 8.83) 2 (,74) 157 44.5 x 8.83 (.74) _ 290 I BOTTOM: , TOTAL: 605' S.F. 447 GPD USE (5) 500 GAL. LEACHING ,CHAMBERS (ACME OR MATTIS DRIVE EQUAL) WITH V STONE AT ENDS AND 2' AT SIDES L= 29.00 , +' 22.a R=50.00 'AL 7t TEST HOLE LOGS - PROVIDE INSPECTION PORT WITHIN 6" FINISH GRADE AH OJALA PE ENGINEER:__________ ' 16.0' - 17.0"1 WITNESS: DAVID FLAHERTY I DATE: � 1/03 3' MAX. < PERC. RATE _ 2 MIN/INCH 14.83! - CLASS I SOILS P# 12.0' 0„ Q ELEV. .— 17 (V LOAM FILL 3" SAND FILL Ap LS 1OYR 5/6 gw LS 1OYR 5/6 C MFS 2.5Y 6/6 5' BOTTOM TH EL.- 7.0' 9m 18" 36" PERC 120" KIO WATFP FPIrrm IMTF•RFh VIV III I; �.. V• L L..II 11 I�. `/-/I T 7+ w i .6WL,)T ARE x6' F = c� 54,'49± SQ. FT ✓ rrc BENCH 'MARK - TOP OF + CONC. BOUND EL. = 14.5 I NOTES: 1. DATUM IS ASSUMED 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. _ - - - - - .^ I' � 1r. VG..:IIVIY C.li/-il.+ ..7 �li� t ._ �. •. _-•-- ` 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED SEPTIC SYSTEM ONLY, AND IS NOT TO BE USED FOR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM' TO SCH. 40-4" . PVC.,, 9. COMPONENTS NOT TO BE BACKFILLED OR 'CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH, 10. PUMP & REMOVE (OFZ FILL W/CLEAN SAND) FAILED LEACHING FACILI T. S. Tr ' OF 18 MATTIS DRIVE: IN THE TOWN OF: YARMOUTH(PORT):­, PREPARED FOR: RICHARD MEYER 30 0 30 60. 90 SCALE: 1" 30' DATE: JULY 7, 2003 a