Loading...
HomeMy WebLinkAboutEngineered Plans - 2013FIRST FLOOR c �� 1 /53.0 T13M = EL. 53.3 DOOR SILL BASEMENT GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERI G FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DEIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 10. EXISTING CESSPOOL TO BE PUMPED, CRUSHED AND FILLED PER TITLE V. 11. 48 HOUR NOTICE FOR ENGINEER CERTIFICATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY UNE SURVEY 13. NO PRIVATE WELLS WITHIN 100 FT. OF PROPOSED LEACHING 14. ALL PIPING TO BE 4" SCH 40 ® 1/8"/FT (UNLESS SPEC. OTHERWISE) 15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER 16. NO WETLANDS WITHIN 100 FT. OF PROPOSED LEACHING 0 48 1 \ 5.3/ 4 \ 1K \\ \ rn5p ports (b6 0 6' T s�e,� 530 52. 2 MEET513REAKOUT \ REQUIREMENTS I L I -c'57 ", W 0 51.G �R. LEGEND PROPOSED CONTOUR ® PROPOSED SPOT GRADE -- gg -- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE W— EXISTING WATER SERVICE TEST PIT �S 'P 00 0� EXIST. CESSPOOL 51 1 (NOTE 10) YARMOUTHPORT DD - II77 FEB 272013 \ LOCUS 349 MAYFAIR RD. LOCUS MAP LOCUS INFORMATION TITLE REF: SK 20539/PG 341 PARCEL ID: MAP 137 PAR. 058 SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 349 MAYFAIR ROAD YARMOUTHPORT, MA PREPARED FOR DEDECKO FEBRUARY 8, 2013 t)F PROP. 1 , 500 GAL SEPTIC TANK }. . Yarmouth Health Department Date SCALE: 1"=20' No. 1140 'PFG/STEL SgNiTAR\a' MEYER & SONS, INC. P.O. BOX 981 EAST SANDWICH, MA. 025371 (508)362-2922 SHEET 1 OF 2 387 NOTE: TO PREVENT BREAKOUT, THE PROPOSED NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS FINISH GRADE SHALL NOT BE < EL:29.11 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. SEPTIC TANK PROPOSED D-BOX PROPOSED S.A.S. T.O.F. EL.=60.0 INSTALL RISERS & COVERS OVER INLET & INSTALL RISER & COVER INSTALL A 4" DIAMETER INSPECTION PORT OVER 14" OUTLET AND SET TO 6" OF FINISH GRADE SET TO 6" OF GRADE ONE F.G. EL.=52.8± CHAMBER (MIN.) AND SET TO 3" OF F.G. LETNGT DD OF MAS`19 F.G. EL.=51.5± F.G. EL:51.3± F.G. EL: 51.2(MAX.) f 9.45" ���� ys DARREN M. L = 10'1 ' 9" MIN COVER/ ! - 36" MAX COVER L - 10' L = 10' MAX ® S=1 % (MIN.) 0 S=1 % (MIN.) 0 S=1 %((MIN) INSTALL TWO INSPECTION PORTS MIN. (MIN.) 1237' 1 l I0. 0 `� 4"SCH40 PVC w 4"SCH40 PVC 4"SCH40 PVC 10" 14" s" 10.75" TO .� Sq \P� NiTAR INV.= 49.75 4a" LIQUID INVERT LEVEL INV.=49.50 INV.= 48.0 COUPLER DETAIL 1I4 PROPOSED GAS BAFFLE D-BOX 3 ROWS OF 6 UNITS ® 5'/UNIT + 1 COUPLERS 0 1.16'/UNIT = 31.16'/ROW .. ......... ...... ,.. INV.=49.0 DB-348.80 _SOIL ABSORPTION SYSTEM (PROFILE) EXISTING 1.000 GALLON SEPTIC TANK EXISTING OUTLET RESTORE VEGETATIVE COVER INV.= 50.0 NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING BACKFILL WITH CLEAN PERC SAND TO TOP OF CHAMBERS 60" PIPE INVERTS PRIOR TO CONSTRUCTION . 2) D-BOX SHALL BE SET LEVEL AND TRUE TO BREAKOUT=TOP ELEV GRADE ON A MECHANICALLY COMPACTED SIX .=48.46 ... • : <• INCH CRUSHED STONE BASE, AS SPECIFIED IN INV. ELEV.= 48.00 310 CMR 15.221(2) BOTTOM ELEV.= 47.13 EXISTING SUITABLE 3) REPLACE EXISTING 1,000 GALLON SEPTIC TANK 2.88' i MATERIAL WITH 1500 GALLON SEPTIC TANK IF FAILED, 5' MIN. ABOVE BOTTOM OF DAMAGED, OR UNDERSIZED. T.P. EXCAVATION OR G.W. EFFECTIVE WIDTH = 3 x 2.88' = 8.64' 4) INSTALL INLET & OUTLET TEES W/ (6.13' PROVIDED) USE 3 ROWS OF 6-ADS ARC 36HC GAS BAFFLE AS REQUIRED BOTTOM OF TESTHOLE EL.=41.0 = (H20) UNITS - NO STONE W/ 1 COUPLERS 5) PLACE SANITARY TEE IN D-BOX. IN EACH ROW SEPTIC SYSTEM PROFILE TYPICAL SECTION N.T.S. N.T A r6" SOIL LOG DESIGN CRITERIA DATE: JANUARY 30, 2013 'NUMBER OF BEDROOMS: BEDROOM DWELLING ���'6' %;�� SOIL EVALUATOR: DARREN M. MEYER, R.S., CSE. #1614 SECTION ro.75" INVERT WITNESS: PHIL RENAUD, YARMOUTH HEALTH DEPT. HEIGHT END CAP SOIL TEXTURAL CLASS: CLASS I DESIGN PERCOLATION RATE: <2 MIN/IN ,DAILY FLOW: 110 G.P.D/BR. DESIGN FLOW: 330 G.P.D. Elev, TP- 1 Depth ADS - ARC 36HC CHAMBER (H2O LOAD). GARBAGE GRINDER: NO (NOT DESIGNED FOR GARBAGE GRINDER) 51.50 A 0" MODEL ARC 36HC SEPTIC TANK: 330 gpd x 200% = 660 gpd USE NEW 1,500 GALLON SEPTIC TANK LOAMY SAND 10YR 4/2 LENGTH 63" NOTE: UNIT CONFIGURATION AND AVAILABILITY SUBJECT 50.50 B 12" EFFECTIVE LENGTH 60" TO CHANGE WITHOUT NOTICE. PRODUCT DETAIL MAY LEACHING AREA REQUIRED: (330)/0.74 = 445.94 S.F. LOAMY SAND 10YR 5/8 DIFFER SIDE WALL HEIGHT 10.75 SLIGHTLY FROM ACTUAL PRODUCT APPEARANCE. DISTRIBUTION BOX: 3 OUTLETS (MINIMUM) 48.25 C 39" OVERALL HEIGHT 16" OVERALL WIDTH 34.5" 194wo 4640 TRUEMAN BLVDHILLIARD, PRIMARY S.A.S. PERC ®46.50 MEDIUM SAND OH/0 43026 USE 3 ROWS OF 6 - ADS ARCHC 3616 H2O UNITS-NO STONE 2.5Y 6/4 CAPACITY 10.7 CF (80.0 GAL) ADVANCED DRAINAGE SYSTEMS, INC. AND EXTENDED 1.16' W/ COUPLER IN EACH ROW PROPOSED SEPTIC SYSTEM SITE PLAN BOTTOM AREA: (GENERAL USE APPROVAL FOR 4.80 SF/LF OF CHAMBER) (CHAMBERS: 6/ROW)18 UNITS x 5.0 LF x 4.80 SF/LF = 432.00 SF 41.0 126° 349 MAYFAIR ROAD, YARMOUTHPORT, MA (COUPLER: 1/ROW) 3 UNITS x 1.16 LF x 4.80 SF/LF = 16.70 SF TOTAL AREA = 448.70 SF PERC RATE <2 ;MIN/IN. ("C" HORIZON) Prepared for: Dedecko DESIGN FLOW PROVIDED: 0.74GPD/SF(448.70SF) = 332.03 GPD > 330 GPD req'd NO GROUNDWATER OBSERVED Engineering b : 9 9 Y MEYER& SONS, INC, Surveying by: 1Ie11er & Assoc. SCALE NTS DRAWN D.M.M. I, Darren M. Meyer, R.S., CSE, hereby certify that I am currently approved by MADEP pursuant to 310 CMR 15.017 to the has PO BOX 981 (508) 375-0735 DATE: conduct soil evaluations and that above analysis been performed by me consistent with the EASTSANDWICH, MA 02537 CHECKED SHEET N0. requirements of 310 CMR t5.017. 1 further certify that I have passed the Soil Eval. Exam in October, 1999. 508-362-2922 02/08/13 D.M.M. 2 OF 2