ROOF RUN OFF
6 IF USING GUTTERS PROVIDE DRY WELLS OTHER-
a- WISE PROVIDE STONE TRENCH FOR DRIP LINE
00
m MAXIMUM BUILDING HEIGHT
n"
GRADE AT STREET SIDE OF BUILDING=19.5
19.5 + 35=54.5=MAX. PEAK ROOF
54.5-(33'-11.5"*)=TOP FOUND.=20.5
*DESIGN DISTANCE FROM PEAK TO TOP FOUND.
RIVERFRONT
ALL OF LOT IS IN THE RIVERFRONT
NEW CONSTRUCTION BEYOND EXISTING FOOTPRINT:
WINDMILL & DECK (RAISE) 661±S.F.
STONE PATIO 846±S.F.
HOUSE, DECK, STEPS 1290±S.F.
TOTAL NEW AREA 2797±S.F.
RUN NEW WATER SERVICE FROM
MAIN HOUSE AND 10' AWAY FROM
SEWER --EXISTING WATER LINE
IS IN SAME TRENCH AS SEWER.
REMOVE SPRUCE
TREE
c y O 13'. '2Ci
43'
PROPOSED FENCE J� .0 2 /
ALONG TOP BANK r / / r
93' /
1 7
/ //
100' ::..:Sy pT oC*
4
f 619
SHOREY ROUND 4' INSIDE DIAMETER
EJECTOR PUMP CHAMBER
DRILL
3/8" WEEP/VENT HOLE
�H
RAISED IN PLACE
Invert
3.66
Bott
ZONING DISTRICT: R25
FRONT YARD: 30'
SIDE YARD: 15'
REAR YARD: 20'
Quick Disconnect/ LOT COVERAGE: 25%
larm 29" Union
On 25" Check Valve
Off 18" 5.83
P EJECTOR PUMP STORAGE CAPACITY: 110 GAL.
X611 STONE UNDER DOSES PER DAY: 3
HIGH GROUND WATER IS
BELOW BOTTOM CHAMBER
ALARM & EJECTOR PUMP NOTES
1. ALARM TO BE WIRED BY ELECTRICIAN ON
SEPARATE CIRCUIT FROM PUMP.
2, ELECTRICAL WORK TO BE INSPECTED BY
WIRING INSPECTOR.
3. ALARM TO BE LOCATED ON COTTAGE.
4. PUMP TO BE CAPABLE OF PASSING
1 1/4" SOLIDS AND INSTALLED IN STRICT
INSTALL ROUND EJECTOR PUMP CHAMBER CONFORMANCE WITH MANUFACTURER'S
EXIST. INV. 8.00 AS SHOWN. SPECIFICATIONS.
5. USE LIBERTY LE41A, 4/5 HP PUMP, CAPABLE
los OF 41 GPM AT 16' TDH
11.2
6 BENCH MARK --TOP & CENTER OF
WOOD STAKE= 13.50 NAVD88
12 '3
S.F.
13 f 1
76
f I . 14 5
•/ 12.03 N /F
KILMAN
17,0
17.7
PROPOSED WATER
LONG STANDING
OCCUPATION
17.48
.7
16
N /F
COFFEY
13.9
las
`i
158
ry 181
PROPOSED 2390±S.F.
4 BEDROOM DWELLING
16.a WITH 241±S.F. EN-
CLOSED DECK
18,3/.
P KIWW 17.772
i Yr
--'---- 00( 1791 C�
17
r
i
OO 17.44
/ 17.43 ,. '.31
17.97 j//
177 1 C. -I-)
EDGE PROP.
DRIVE
LEGEND
TH 1
TEST HOLE LOCATION, NUMBER
-W-
WATER LINE MARKINGS
E-
OVERHEAD ELECTRIC WIRES (IF SHOWN)
-5--
GAS LINE MARKINGS
9.5 x18.3
EXISTING & PROPOSED ELEVATIONS ('X' MARKS POINT)
2.
EXISTING CONTOUR
_8,
PROPOSED CONTOUR
0
UTILITY POLE (IF SHOWN)
1B
EXISTING DRAINAGE CATCH BASIN
x -
FENCE (IF SHOWN, NOT ALL SHOWN)
ALL PIPES TO BE 4" SCH 40, AND PITCHED AT 1/4" PER FOOT. (UNLESS NOTED)
TREE (IF SHOWN, NOT ALL SHOWN)
----------
PROPOSED WORK LIMIT
REV. 08/09/2016
--SLAB, FOUND., RESERVE AREA, TANK, EXIST. HOUSE GONE
REV, 12/22/2015 --BOARD OF HEALTH CHANGES
REV. 10/23/2015 --PATIO
17,0
17.7
PROPOSED WATER
LONG STANDING
OCCUPATION
17.48
.7
16
N /F
COFFEY
13.9
las
`i
158
ry 181
PROPOSED 2390±S.F.
4 BEDROOM DWELLING
16.a WITH 241±S.F. EN-
CLOSED DECK
18,3/.
P KIWW 17.772
i Yr
--'---- 00( 1791 C�
17
r
i
OO 17.44
/ 17.43 ,. '.31
17.97 j//
177 1 C. -I-)
EDGE PROP.
DRIVE
PROP.TOP FOUND=20.5
NU Its
JOB NO. Y14-37
Harwich outwash plain deposits
C1 layel
TWO COMPARTMENT
PALMER2.DWG
1.
LOCUS IS A.M. 22, PARCEL 59.
FB 30/63 SB 13/62
3 DRY WELLS (H-20)
2.
ELEVATIONS SHOWN ARE NAVD88 t0.1' USING VERTCOM.
SEPTIC TANK
3.
LOCUS IS IN FLOOD ZONES: VE(EL.13), AE(EL.11), X(0.2% RISK), X (OUTSIDE 0.2% RISK)
6"
or compact9.6
Proposed
ON FIRM PANEL 0569J DATED JULY 16, 2014. BOUNDARIES SHOWN ARE SCALED.
-------------- Use Gas Baffle
4.
ALL PIPES TO BE 4" SCH 40, AND PITCHED AT 1/4" PER FOOT. (UNLESS NOTED)
14.33
5.
MUNICIPAL WATER IS AVAILABLE. LOTS WITHIN 100' ARE ON TOWN WATER.
�a
6.
COMPONENTS TO BE AASHTO H-10, UNLESS NOTED.
m�
7.
INLET TEE TO PROJECT DOWN 13", OUTLET TEE DOWN 14".
J°�\
8.
IF TWO OR MORE LINES, WATER TEST D -BOX FOR EQUAL FLOW
SLAB=15.3
G
D -BOX EXIT PIPES TO BE LEVEL FOR FIRST TWO FEET.
Filter Cloth=14,5
9.
DEPTH OF COMPONENTS NOT TO EXCEED 3', OR VENTING MUST BE PROVIDED.
2000 Gal.
Se tic Tank
S=1
COVERS: BUILD UP COVERS TO 6" BELOW GRADE --2 ON TANK, D -BOX, PUMP CHAMBER, 2 ON LEACHING.
nom
10.
STONE TO BE DOUBLE WASHED 3/4 TO 1 1/2" WITH 2" MIN. 1/8 TO 1/2" PEA STONE ON TOP.
LOCA1
11.
IF UNSUITABLE SOILS, OR SOILS DIFFERING FROM THE SOIL LOG ARE FOUND,
CONTACT THE BOARD OF HEALTH, OR R.J. CADILLAC.
12.
IF AN OVERDIG IS CALLED FOR BELOW, FILL MATERIAL FOR 5' AROUND AND UNDER LEACHING
IS TO BE CLEAN GRANULAR SAND MEETING SPECIFICATIONS OF 310 CMR 15.255(3).
TEST f
13.
PUMP AND FILL ANY EXISTING CESSPOOLS. REMOVE ANY CLOGGED SOIL, BLOCK, AND STONE IN
LEACH AREA, AND DISPOSE OF AS DIRECTED BY HEALTH AGENT.
DEPTH (inche
14.
ALL CONSTRUCTION TO MEET TITLE 5 AND LOCAL REGULATIONS.
0
A layer
TEST HOLE DATE: November 5, 2014
81,
sand
PERFORMED BY: Ron Cadillac, Soil Evaluator
WITNESSED BY: Amy Von Hone, RS, CHO
B layer
PERC RATE: <2'-00"/inch (Cl &C2 layers)
sand
SOIL SURVEY(1993): Carver coarse sand
30"
PROP.TOP FOUND=20.5
pH -20
GEOLOGIC MAP(1986):
Harwich outwash plain deposits
C1 layel
TWO COMPARTMENT
64"
fine i
15T-1100 GAL/2ND-900 GAL
Invert 15.10
3 DRY WELLS (H-20)
loam,
Invert 15.85
SEPTIC TANK
4' OF STONE ON THE ENDS
64"
6"
or compact9.6
Proposed
Use Gas Baffle WITH TWO COVERS
-------------- Use Gas Baffle
522.5 SF
Invert
14.33
C2 la e
y
15'
N r- 1'-
TWO METAL
H-20 COVERS
SIDE LEACHING AREA:
Proposed Top Conc.=15.0
„
S=1 /4 /ft
_ 15,
Top Peastone/
med. cc
SLAB=15.3
G
„ H-20
S=1 /4 /ft
Filter Cloth=14,5
(trac
Invert 15.35
2000 Gal.
Se tic Tank
S=1
/811 /ft --s" Max. Screened
1 137"
nom
THIS PLAN IS A VALID COPY ONLY IF IT BEARS
AN ORIGINAL RED STAMP AND SIGNATURE.
n"n"iii n%p"1111 nrrI\vrnL-
DATE
Proposed
pH -20
a
-=--------
GARBAGE GRINDER:
No
64"
REQUIRED CAPACITY:
550 GPD
T
Stone
Invert 14.50
Invert 14.17
WITH
4' OF STONE ON THE ENDS
12.17
5.97 Bottom
6"
or compact9.6
Proposed
Proposed
i
522.5 SF
SIDES, FSR A 47-6" LONG BY 11'
25'
I
r 30'
15'
N r- 1'-
BY 2' DEEP LEACH AREA.
SIDE LEACHING AREA:
Bottom TH1=6.2
I
_ 15,
G
USE
Estimated High Groundwater=2.5 NAV088
DESIGN DATA
BEDROOMS• 5
THE WIDTH OF THE BED VARIES FROM
8'-6" TO 10'-6", AS SHOWN.
CAPACITY -557 GPD
SITE PLAN
FOR
TEST f
DEPTH (inche
0
A loyer
sand
8'
B layer
sand
28„
a
LEACH AREA
GARBAGE GRINDER:
No
64"
REQUIRED CAPACITY:
550 GPD
USE
3 DRY WELLS SET 7' APART
med. cc
WITH
4' OF STONE ON THE ENDS
SEPTIC TANK:
1500 GAL.
AND
APPROX. 3' OF STONE ON THE
BOTTOM LEACHING AREA:
522.5 SF
SIDES, FSR A 47-6" LONG BY 11'
[(47.5' X 11')]
WIDE
BY 2' DEEP LEACH AREA.
SIDE LEACHING AREA:
234 SF
RESERVE
[2(11'+ 47.5') X 2' DEEP)]
USE
4 DRY WELLS SET 4' APART
DESIGN CAPACITY:
559.8 GPD
AND
WITH 3'-6" OF STONE ON THE
[(522.5 SF + 234 SF) X .74
GPD/SF]
ENDS
CENTERED IN 53' LONG BED.
THE WIDTH OF THE BED VARIES FROM
8'-6" TO 10'-6", AS SHOWN.
CAPACITY -557 GPD
SITE PLAN
FOR
TEST f
DEPTH (inche
0
A loyer
sand
8'
B layer
sand
28„
a
C1 laye
60" a
fine
loam
64"
C2 laye
med. cc
(trac
137'
no v
Yarmouth Health Departm
ameAPP�VED
Da
DAVID & MELISSA PALMER
LOT 42 33 CREST CIRCLE, WEST YARMOUTH, N
OCTOBER 1, 2015 SCALE: 122=202
RONALD J. CADILLAC, PLS, RS, P.C.
PROFESSIONAL LAND SURVEYOR & REGISTERED SANITARIAN
P.O. BOX 258
WEST YARMOUTH, MA 02673
(508) 775-9700
C)2015 BY R.J. CADILLAC
191 o