Loading...
HomeMy WebLinkAbout83 South Sea Avenue Site PlanSOIL TEST PIT DATA NOT TO SCALE TEST PR TP -1 TEST PR TP -1 GRD. EL 9.3 GRD. EL 9.3 SHGW EL 4.2 SHGW EL 4.2 EL 8.5 EL 7.1 EL 6.3 EL 4.2 EL 3.5 07 A SANDY LOAM 10YR 3/6 B SANDY LOAM 10YR 5/6 C-1 FINE SAND 2.5Y 5/6 C-2 COURSE SAND 10YR 5/8 N 10' EL 8.5 26' EL 7.1 36' EL 6.3 44" DATE 61' EL 4.2 70" EL 3.5 90/135, 294/80, 17149-F WITNESSED BY, �1111111AIIIII SANDY LOAM IOYR 3/6 B SANDY LOAM 10YR 5/6 C-1 FINE SAND 2.5Y 5/6 C-2 COURSE SAND 10YR 5/8 LOCUS INFORMATION ONSITE SOIL EVALUATION RICHARD HARDING DREW DATE AUGUST 13, 2016 TITLE REFERENCE: TEST BY: BSC GROUP, INC. 90/135, 294/80, 17149-F WITNESSED BY, AMY VON HONE, RC, CHO, BOH PARCEL: LICENSED SOIL EVALUATOR: KIERAN J. HEALY, SE, PLS. 10' PERCOLATION RATE <2 MINS./INCH F SOIL CLASS: CLASS 1 26' LT.A.R.: 0.74 GPD/S.F. 36' ADJUSTED SEASONAL HIGH GROUNDWATER ZONE: NOT A ZONE 11 SEASONAL HIGH GROUNDWATER ADJUSTMENT 'AE", EL -11, 7/16/14 44" PANEL #25001CO588 J EXISTING LOT SIZE: 28,150# S.F. DEPTH TO OBSERVED WATER 5.8' INDEX WELL MMI -29 WATER LEVEL RANGE ZONE" A B LOCUS INFORMATION CURRENT OWNER: RICHARD HARDING DREW 4' INVERT AT BUILDING NANCY LOUISE DREW TITLE REFERENCE: DEED BOOK 4083, PAGE 023 PLAN REFERENCE: 90/135, 294/80, 17149-F ASSESSORS MAP: 23 PARCEL: 156 ZONING DISTRICT: R-25 SETBACKS: FRONT 30' F SIDE 15' YARMOUTH HEALTH DIVISION. REAR 20' OVERLAY DISTRICT: NONE NITROGEN SENSITIVE ADJUSTED SEASONAL HIGH GROUNDWATER ZONE: NOT A ZONE 11 FEMA FLOOD ZONE DISTRICT: 'AE", EL -11, 7/16/14 PANEL #25001CO588 J EXISTING LOT SIZE: 28,150# S.F. 2. >1 61 ASSESSORS MAP 23 DEPTH O INDEX WELL ON 6/16 8.3' PARCEL 160 WATER LEVEL ADJUSTMENT 1.7 1 70' 0.7' USING 1.0' OFF CCC ADJUSTMENT yen• e. -%0S EL (- )UGrIn IV ^Vo. w\VV, n�,u• --• A 4' INVERT AT BUILDING LEGEND « THE PROPERTY IS LOCATED NEAR THE B 4' INVERT AT SEPTIC TANK (IN) INTERFACE OF THE CAPE COD COMMISSION C 4' INVERT AT SEPTIC TANK (OUT) UNSUITABLE- ESTIMATED A AND B OVERLAY DISTRICTS ASSOCIATED D 4' INVERT AT DIST. BOX (IN) MATERIAL SEASONAL HIGH WITH MIW-29. THE PLAN IS USING THE E 4' INVERT AT DIST. BOX (OUT) AT LEACHING FACILITY: GROUNDWATERLj ZONE A FOR DESIGN PURPOSES, PER F ELEVATIONS 4' INV. AT LEACHING CHAMBERS YARMOUTH HEALTH DIVISION. G (BRKOUT 10.0) BOTTOM OF LEACHING CHAMBERS PERCOLATION �- OBSERVED GROUNDWATER H ADJUSTED SEASONAL HIGH GROUNDWATER LEST RANGE J GENERAL NOTES 1. THIS PLAN IS INTENDED FOR THE PERMITTING, DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYSTEM AND ASSOCIATED SITE WORK. 2. ALL CONSTRUCTION METHODS AND MATERIALS SHALL CONFORM TO 310 CMR 15.000 AND YARMOUTH BOARD OF HEALTH REGULATIONS. 3. THERE ARE NO KNOWN OR PROPOSED PRIVATE WEDS LOCATED WITHIN 150 FT. OF THE PROPOSED LEACHING FACILITY. a 4. IF AN OVERDIG IS SPECIFIED, REMOVE ALL TOPSOIL, SUBSOIL AND OTHER UNSUITABLE MATERIALS. 5. IF AN OVERDIG IS SPECIFIED, REPLACE ALL EXCAVATED MATERIALS WITHIN THE LIMIT OF EXCAVATION WITH CLEAN GRANULAR SAND, FREE FROM ORGANIC MATERIAL AND DELETERIOUS SUBSTANCES. MIXTURES AND LAYERS OF DIFFERENT CLASSES OF SOIL SHALL NOT BE USED. FILL SHALL NOT CONTAIN ANY MATERIAL LARGER THAN 2 INCITES. A SIEVE ANALYSIS USING A f4 SIEVE SHALL BE PERFORMED ON A REPRESENTATIVE SAMPLE OF FILL UP TO 45% BY WEIGHT MAY BE RETAINED ON THE #4 SIEVE SUCH ANALYSES MUST DEMONSTRATE THAT THE MATERIAL MEETS EACH OF THE FOLLOWING SPECIFICATIONS: 100% MUST PASS /4 SIEVE 10% MUST PASS $50 SIEVE 0-20% MUST PASS f100 SIEVE 0-5% MUST PASS #200 SIEVE 6. EXISTING UTIUTIES WHERE SHOWN ON THE PLANS ARE APPROXIMATE. THE ENGINEER DOES NOT GUARANTEE THEIR ACCURACY OR THAT ALL SUBSURFACE STRUCTURES ARE SHOWN. CONTRACTOR SHALL VERIFY THE SIZE, LOCATION AND ELEVATION OF INVERTS OF UTILITIES AND STRUCTURES, C WITHIN THE LIMIT OF WORK. PRIOR TO THE START OF CONSTRUCTION. IF ANY DISCREPANCIES ARE �p DISCOVERED OR FIELD CHANGES REQUIRED, THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY. 4 v 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROPERLY COORDINATING THE PROPOSED UTIUTY COMPANIES, AND SHALL CONSTRUCTION ACTIVITIES WITH DIG -SAFE AND THE APPUCABLE COMPLETE THE PROPOSED WORK WITHOUT ANY INTERRUPTIONS IN SERVICE. GO 8. CONTRACTOR IS REQUIRED TO NOTIFY DIG -SAFE. PER MASS. STATUTE CHAPTER 82, SECTION 40 1'q (888) 344-7233 A MINIMUM OF 72 HOURS PRIOR TO THE START OF CONSTRUCTION.9. rNAD THIS SYSTEM IS NOT DESIGNED FOR THE USE OF A GARBAGE GRINDER. INSTALLATION OR USE OF A GARBAGE GRINDER AT THIS PROPERTY IS NOT ALLOWED PER 310 CMR 15.240(4). VARIANCES REQUESTED NONE Quick4 Plus Standard Low Profile Chamber dIII '118. (EFFECTIVE LENGTH) Quick4 Plus All -in -One 8 dcap Quick4 Plus Endcap 10.4' EFFECTIVE I�-�- LENGTH' When installed between 2 chambers. T 13.3" T I►-- 18' EFFECTIVE 3.3' 3 3, LENGTH' INVERT INVERT When installed at the end of a trench. = Ql/IC,It4�"FLUS EFFECTIVE LENGTH' ASSESSORS MAP 23 PARCEL 155 LCP 17149-F X 10.4 N RY ��u KERVAR�B� SCHEDULE OF ELEVATIONS TOP OF FOUNDATION 12_20 A 4' INVERT AT BUILDING 10.40 B 4' INVERT AT SEPTIC TANK (IN) 10_12 C 4' INVERT AT SEPTIC TANK (OUT) 9_87 D 4' INVERT AT DIST. BOX (IN) 9_70 E 4' INVERT AT DIST. BOX (OUT) AT LEACHING FACILITY: 9_53 F ELEVATIONS 4' INV. AT LEACHING CHAMBERS 9.47 G (BRKOUT 10.0) BOTTOM OF LEACHING CHAMBERS 9_20 H ADJUSTED SEASONAL HIGH GROUNDWATER 4_20 J SYSTEM PROFILE NOT TO SCALE 4' SCH. 40 PVC L-14 FT. S=0.02 EnY 1,500 GALLON SEPTIC TANK W4m MAGNETIC REFLECTIVE TAPE SHALL BE PROVIDED IN THE TRENCH OVER ALL PVC PIPING 4' SCH. 40 PVC L=17.0 FT. S=0.01 FIRST PIPE LENGTH TO BE SET LEVEL FINISH GRADE FOR MIN. 2' 10.9-11.2 4' SCH. 40 PVC PROPOSED I u, 14, POLY LINER TOP 10.3 BOTTOM 7.8 1=G 1=F H LEACHING CHAMBERS DISTRIBUTION 5' SEPARATION PROPOSED BOX J j ESTIMATED SEASONAL HIGH GROUNDWATER P OF AN K (� sorms ~ " NOT TO SCALE NOTES: ....� 1. SEPTIC TANK SHALL BE STEEL REINFORCED CONCRETE. 2. SEPTIC TANK SHALL BE CAPABLE OF WITHSTANDING H-10�j- LOADING. 3. ALL PIPE CONNECTIONS AND CONCRETE CONSTRUCTION SHALL BE WATERTIGHT. 4. TEES SHALL BE SCH. 40 PVC AND SHALL BE LOCATED WITHIN 12" OF TANK WALL AND ACCESSIBLE FROM TANK6, MAX - 5. COVER COVER. 5. FILL ALL UNUSED KNOCKOUTS WITH HYDRAULIC CEMENT. EL 12.3 4" 100-60 10-0"� ,D" I � 4' MIN. UQUID 5'-8' 4'-6' LOCATE DEPTH _a 5'-8" lO O _ INLET TEE OUTLET TEE UNDER COVER W/GAS BAFFLE 3' 3" __j IBOTTOM 5.1 Z EL 5.75 3.5 PLAN VIEW CROSS-SECTION VIEW REMOVABLEr 6' MAX. COVER -1 I HDPE RISER (IF NEEDED)-,.,., 2' F 3' 9 1/2" O O 11 1/2" a 2' BOTTOM ON LEVEL STABLE BASE 6MINIMUM 3/4' TO 1-1/2' 21' --� CRUSHED STONE SECTION VIEW PLAN MEW (5) 5' DIA. KNOCKOUTS (TYP.) 12" DIA. COVER W W PRS m� NOTES• 1 -BEDROOM COTTAGE (20x20) X 10.0 00 1. DISTRIBUTION BOX TO WITHSTAND H-10 LOADING. FIRST FL '= 13.2 0 10.1 X m 2. ALL PIPE CONNECTIONS AND CONCRETE CONSTRUCTION SHALL BE WATERTIGHT. 01 3. FIRST TWO FEET OF PIPES OUT OF DISTRIBUTION BOX SHALL BE LAID LEVEL. t o? BUILDING 03 #2 4. FILL ALL UNUSED KNOCKOUTS WITH MORTAR. ;0 '•, _EXIS77NG 5. CONCRETE COVER SHALL BE SET WITHIN 6 INCHES OF FINISHED GRADE. EXIS77NG GARAGE 12.0 LEACHING o ', 0 AREAS m 0 `', G L. .o ASSESSORS MAP 23 PARCEL 157 DESIGN CALCULATIONS. -��OBSERVATION PORT EXISTING FLOW / PROPOSED FLOW NOT TO SCALE 1 BEDROOM 0 110 GPD/BEDROOM = 110 GPD SUITABLE COVER � THREADED CAP 1� MINIMUM DESIGN FLOW 2 BEDROOMS ® 110 GPD/BEDROOM = 220 GPD 3" MAX EXIS77NG I FINISH GRADE DWELLING i REQUIRED SEPTIC TANK 10.7 220 GPD X 200% = 440 GALLONS USE 1,500 GALLON SEPTIC TANK O ` SIZE OF REQUIRED LEACHING FACILITY 1 DESIGN PERC. RATE: <2 MIN/INCH OBSERVATION PORT SHALL BE INSTALLED GPD SF INSTALLED UTILIZING THE 4' SCH. PVC LONG TERM APPL RATE: 0.74 / KNOCIC011T ON THE TOP OF THE O PERFORATED PIPE 220 GPD + 0.74 GPD/SF = 297 SF QUIK-4 CHAMBER AND SHALL EXTEND DOWN TO THE EXISTING SIZE OF LEACHING FACILITY PROVIDED SUBGRAW- SEE PLAN VIEW FOR O 1 5pp��!R�CORD oy USE 16 QUIK-4 LEACHING CHAMBERS IN FIELD CONFIGURATION LOCATION OF OBSERVATION PORTS. 2 LAND COURT S��y�i1p025 U�i �`\ IN ACCORDANCE WITH MASSACHUSETTS DEP APPROVAL, EFFECTIVE LOADING BOUND FOUND 11.2 AND HELD i /1 , /E ' RATE IS 4.80 SF/LF OF CHAMBERS N SEApE 4.0 LF/CHAMBER X 16 CHAMBERS = 64 LF O 64 LF X 4.80 SF/LF = 307 SF ze, ° co� pUB�C ��' oN ` 307 SF X 0.74 GPD/SF = 227 GPD INSTALLED CAPACITY//./%//%//%//�///�//�//,�/�/%%/ V TI �i� 227 GPD PROVIDED > 220 GPD MIN. REQUIRED EXISTING SUBGRADE