HomeMy WebLinkAbout83-1465 - Sewaqge Disposal - DetailsDEEP
SOIL
HORIZON
SOIL
TEXTURE
SOIL COLOR
(MINSELL)
OBSERVATION
+-TOLE
L005
FILL
NO SCALE
DEEP OBSERVATION HOLE I EL. = 8.4
DEPTH FROM
SURFACE
SOIL
HORIZON
SOIL
TEXTURE
SOIL COLOR
(MINSELL)
SOIL
MOTTLING
OTHER
0" - 24'
FILL
#100
0%-20%
0 200
EAST 5VE OF Nola NAD
BLC6. DEBRIS TO 66'
24' - 42"
B
LOAMY SAND
IOYR4/b
SHEET TIRE
L.£/aER
42' - 66'
GI
SAND
IOYR5/6
NONE
COARSE TO
66' - 132'
C,2
SAND
IOYR6n
NONE
MMILIM TO
C40ARBE SAV
DEEP OBSERVATION HOLE 2 EL. = 8.5
DEPTH FROM
Sa' IRFAGE
SOIL
HORIZON
SOIL
TEXTURE
SOIL DOLOR
MINSELL)
SOIL
MOTTLIN5
OTHER
01-10,
FILL
#100
0%-20%
0 200
6RAVE '`w
10" - 21'
B
LOAMY SAND
IOYR4/b
SHEET TIRE
L.£/aER
21' - 120'
G
SAND
I0YR5/b
NONE
HDtH TO
COARSE SoqV
3 1 CN GALGULA-
DATE OF TE -5T5: 4/29/98
PERGOLATION RATE : LE55 THAN.2 MINANGH IN "G" HORIZON
HITNE55M BY : A 5(,HNAIBLE, GEC,
BRUCE MURPHY, HEALTH A6ENT
6ROUNDWATER ENCOUNTERED AS NOTED
6ROUNDWATER ENCOUNTERED AT
A DEPTH OF 61'
6ROU4DWATER ENCOUNTERED AT
A DEPTH OF 51'
DE516N FLOW: TITLE 5: TAKE-OUT RESTAURANT= 12 5EAT5 x 20 6PV = 240 6PP WE 1000 6PD )
AGIUAL WATER USE (1/43 - IM) : AVG = 419 6PD (FOR A 51MILAR ESTABLISHMENT)
KITCHEN FLOW: 12 5EAT5 x 15 6PD = 180 6AL
A 40'Nbc 34'L x 0'-6'D. LEAGHIN6 FIELD CAN LEACH: Vt= 40 x 34 x .14 = 1006.4 6PD
INSTALL: ONE (1) - 40'W x 341- x O' -6'D. LEAGHIN6 FIELD Vt = 1006.4 6PO ) 1000 6PD REOV.
ONE (1) - 2000 6AL. 5EPTIG TANK, MINIMUM ALLOWED
ONE (1) - 1500 GAL 6REA5E TRAP
ONE ( 1) - 2000 6AL. PUMP CHAMBER W/ PUMP 4 GONTROLS
ONE ( I) - D15TRIBUt1oN Box - (9 OUTLET)
NOTES
1) 6ARBASE 6RINDEP-5 ARE NOT ALLOWED WITH THIS DE516N.
2) THE INSTALLER IS RESPONSIBLE FOR AS%RIN6 THAT COMPONENTS OF
THE SF-WA.GE DISPOSAL SYSTEM ARE DE-516NW WITH SUFFICIENT
STRENGTH TO SUSTAIN ALL LOADS TO BE IMP05ED ON THEM. ANY
COMPONENT OF THE SYSTEM 5UB.EGT TO VEHICULAR TRAFFIC, MU5T
OOMPLY WITH A MINIMUM STANDARD OF AA.S.H.TO. H-20 WHEEEL. LOADS.
3) PRIOR TO SETTING ANY SEWAGE DISPOSAL SYSTEM COMPONENT, INSTALLER
SHALL VERIFY EXISTING CONDITIONS, INCLUDINI6 ELEVATIONS OF EXIT INVERTS,
AND REPORT ANY DI5CREPANGIE5 TO THE DE -516N ENGINEER
4) ALL 6RAVITY SB•!ER PIPE SHALL BE 4' DIA. SCH 40 PVC, UNLESS OTHERWISE
NOTED. THE MINIMUM SLOPE OF 4' DIA. SCH 40 PJC, SHALL BE ODI FT/FT.
5) NO PART OF THIS DE51614 SHALL BE ALTERED WITHOUT' PRIOR APPROVAL
FROM THE DEVCM ENGINEER AND THE AGENT OF THE LOCAL BOARD OF
HEALTH. ALL REQUESTS FOR CHANGES SHALL BE MADE IN WRITING PRIOR
TO GON5IRUGTION.
6) THE USE OF ALTERNATE MANUFACTURERS FOR SYSTEM COMPONENTS
SHALL NOT BE APPROVED IF THE USE OF THEIR EQUIPMENT REQUIRES
CHAN6E5 IN DE516N.
7) THE INSTALLER SHALL ASCERTAIN THE LOCATION OF EXI51IN6 VVER6ROUND UTILITIES PRIo
TO E)rAVA110K AND SHALT PROTECT UTILITIES WITHIN THE THE HORK AREA WRNG CC%TRZTION
b) THE EXISTING SEWAGE DISPOSAL SYSTEM SHALL BE PIMPED AND REMOVED
WITH 5URROUNDIN6 CONTAMINATED SOILS AND BAGKFILIED WITH CLEAN
COARSE SAND.
IF APPLIGABLE,
N FILL MATERIAL FOR 5Y5TEM5 CONSTRUCTED IN FILL SHALL BE GLEAN
6RAM-AR SAND, FREE OF ORGANIC MATTER AND OTHER DELETERIOUS
MATERIALS. THE SAND SHALL BE 6RADED SUCH THAT NOT MORE THAN
45% OF THE SAMPLE, BY WEIGHT, SHALL BE RETAINED ON THE #4 SIEVE.
THE FILL SHALL NOT CONTAIN ANY MATERIAL LAR6ER THAN 2 INCHES.
THE MATERIAL THAT PASSES THE M4 SIEVE SHALL MEET THE
FOLLOWING GRADATION REQUIREMENTS,
SIEVE
PERCENT
SIZE
PA55146
a 4
100%
#50
1051 100%
#100
0%-20%
0 200
0%-5%
PROPOSED FLOOR
EL= 12.25
1025 1 950
THE MINIMUM SLOPE FOR
4' DIA SUI 40 PVC PIPE
15 1/8' PER FT ..1
ESTIMATED H16H 6ROUNDWATER CALCULATION
NS95/CCG METHOD)
INDEX WELL: # MIH -2q- ZONE:_A
DATE OF READING: 4/28/98 DEPTH TO 6ROUNDWATER: 626
GROUNDWATER LEVEL ADJUSTMENT: 0.4
AGTUAL 6ROUNDWATER LEVEL ® 51TE: EL= 420
ESTIMATED (MAX) HIGH 6ROUNDWATER LEVEL: EL= 4160
PUMP 5PEG I F I GATI ON5
I. R1MIx' TO BE MY625 PH;5
51O43RS113LE SB•IA6E RMI -5, I/2 HP
SINGLE PHASE, 230 VOLTS
PUMP RATE = 173.1 6PM O 162 TVH
2. CONTROLS ARE TO BE FOR A DUPLEX
ALTERNATING PUMP SYSTEM.
3. FORGE MAINS TO 13E 2' DIA 50H 40
PJC PRESSURE PIPE WITH A MIN. OF Y OF COVER
15 C.F. POURED CONCRETE THRUST BLOCKS ARE TO
BE PROVIDED AT FORGE MAN ANGLE POINTS.
FORCE MAIN SHALL DRAIN TO PUMP CHAMBER.
4. A SEPARATE CIRCUIT H16H WATER ALARM
5HALL BE INSTALLED WITH THE F" CONTROLS.
5. EACH PUMP SHALL BE ON A SEPARATE
CIRCUIT
b. A MTERS SRA -20O -CV RAIL PUMP LIFT OUT
SYSTEM SHALL BE INSTALLED FOR EACH PLIMP.
1. ALL PUFF INSTALLATION HARDWARE, INSLIDIN5 RAILS,
%HALL 13E STAN E55 STEEL.
POSED FLOOR
EL = 1225
4' DIA SCH 40 PJC, PIPE
OR AS REOV BY THE
MASS PLUMBINI(9 CODE
NEW T1'R) BLDG) >
KITCHEN WASTE ONLY s
10.25 IOAO
THE MINIMUM SLOPE FOR 7.
4' DIA SCH 40 PVC, PIPE
15 1/81 PER FT
1=Lw1=-1
im
/'- ZABEL FILTER
/MODEL A300 W/ STRAP
SUFTORTS TO TOP OF TANK
f 4' DIA SCH 40 PVC, TO
SEPTIC TANK
1 4.15 1
1500 GAL GREA5E TRAP
(H-20) 67 TO SEPTIC TANK, 3'
NOT TO 5GALE
261 EHCf FRAME AND COAR
TO FIN15H 6RADE•
Ir C49VER HALLIr - •-
• FIN15H 6RAVE• X 4V HIH 304b Z7 ABOVE•
OR APPROVED EGUAL
o • • :•
_ 420
Ie7sae°R�r-nre'
PUMP HU
�
(fYPIGVJ
(H-20)
uwD H 4'1
D>r raDH now Lnene
4 F 14 WG
TANK INSIDE
6 Fr a4 WA Was
7 FT 24 roes
10'L x 5'W
2,&00 GAL M-20)
REVISION
ONE COMPARTMENT SEPTIC, TANK
SHEET TIRE
- r - • v
AT FAGTORY - AND GERTIFIED BY MANLFAGTURERPRIOR TO IN5TALLATION.
12'1
LONGEST RUN = 22'
NOTE
SEPTIC TANK AND PUMP GHAMBER SHALL BE
OF KATERT16HT DE516N AND SHALL BE TE5TED
FOR WATER TIGHTNESS AFTER INSTALLATION A5
FOLLOWS: I. FILL TANKS
2.24 HOUR5 AFTER FILLIN6 MEASURE WATER LEVEL
3.45 HOURS AFTER FILLING REMEASURE WATER LEVEL
BENCHMARK - PK NAIL S SIDEWALK
ELEV. = 10.58 (N.G.V.D.) RUN RM 2D
PROPbSED VENT PI
ASSESSORS MAP 24
PARCEL K1
U
.1
PROP SED BIT.
CONC-BERM
?0 I
0 3 \
/ b
7
�' :✓.•.,.. s r, 3 0 ATO
/ PROPOSED D- BOX 4' syn CONCRETE O
\S
PROPOSED VEGETATIVE / ; T FF' •fR > `,1 , •` F Tq
SCREENING � / °'/ � �• �,,2 3 c� .y ' �xp� 0
4' HIGH x 5' 'v DE-
).:,
PROPOSED 2000 J,
GALLON PUMP
CHAMBER (H-216) „ ,RESE A 4 T p
-T-
Q.1
- m pp
1Q.1
PROPOSED 20 1 /
GALLON SEPTIC / " " R 1�."
TANK (H-20),/� '-75-
k, PROPOSED
RECHARGE 7,
/ FIELD A
PROPOSED 1500 It o4,
GALLON !GREASE TANK
(H-zo) l ' o io% �ti�s°jyc°o _ ..I / R > 501L REMOVAL NOTE
U
50
'�$x SlgeSopyGTS �•�k j „' ��: WTHIN 5' OF PROP05ED SOIL ABSORPTION SYSTEMS REMOVE
ALL MATERIAL DOWN TO THE NATURALLY 00CURIN6 SAND ("C")
r f� ter
r�,s f� r,ritA.
' FINISH COURSE, GLASS I TYPE 1-1 BIT. GONG.
2' BINDER COURSE, GLA% I TYPE 1-1 BIT. GONG.
PAVEMENT BASE Z SUBBASE MATERIAL SHALL BE COMPACTED
4' DENSE GRADED CRUSHED STONE (MI .03.0 TO 95% MAX DRY DENSITY (based upon AASHTO T180 Method D).
REMOVE TOP501L AND OR6ANIG MATTER PRIOR TO PLACEMENT
OF FILL MATERIALS
TYPICAL PAVEMENT 5ECTION OVER LEACHING FIELD
NO SCALE
V --
A
PROPOSED
RECHARGE
� ' FIELD B
v'
/ 2 / STRATi1M ( 3TO 4 FEET BELOW GRADE) AND REPLACE WITH GLEAN
PREVIOUS LOCATION SAND TO ELEVATION 11.0. FILL MATERIAL SHALL MEET THE 5PECICATION5
/ OF RAZED BUILDING OF NOTE 4 AT LEFT.
BOLlA1R['k9 ,,:. - / 7x3 y '
I HEREBY CERTIFY THAT THE EXIS77NG CONDITIONS SHOWN HEREON -
- - - / ARE LOCATED AS THEY EXIST ON THE GROUND AND THAT THE
PROPERTY LINES SHOWN HEREON REFLECT EXISTING PLANS AND
'• DEEDS OF RECORD.
6A OF
/t5-
71/ EDGE 91T
BERM' I _ _ --� _ ��� DATE' I� 130 b19 -P.L.
_� ..�� ..�� �fior32t
m�_ Lo_� CONT' RE'T�INING WALL (BY CHASE'S BROOK��'''''�'
/ /j Wq/UARD RAIL
/ 6 .0/NALL EL. 11.2 :; t INSPECTION` SSE
THE STATE ENVIRONMENTAL TITLE
DISPOSAL
MTEEM B S, REQUIRES IN5P INEER-YS)
OF THE SEWAGE DI BY DESIGN RN61N✓ffR.
INST I I ATION CA2ffRACJOR MUST NOTIFY THE DE516N EN61WER
LANPRIOR TO THE START OF INSTALLATION FOR DISO.%ION ON
40' Wx 34'L x O'-b"D LEAG44IN6 FIELD INSPECTIONS SGHEDU Es
0 AFTER EXCAVATION ! REMOVAL OF OLD FIELD
MIRAFI 50OX FILTER FABRIC SCALE: I"= 20' 2) AFTER PLACEMENT OF 19LL
OVER STONE ON LEAGHIN6 FIELD
2" LAYER OF I/8" TO 1/2'
WASHED STONE
4' DIA, SCH 40 PVC VENT PIPE
50' KSIRD SCREEN
1 I/2' VIA. PERF. SCH 40 PVC
O' - b' OF STONE
DEPTH TO ESTIMATED
MAXIM.M HIGH 6ROLWHATER
EST. MAX H16H 6ROUNDWATER
L= 416
OBSERVED 6ROLNIMATER
L= 42
SG HEMAT I G FLON PROFILE,
ALL INSTALLATIONS MUST CONFORM TO, THE MINIMUM REQUIREMENTS OF TITLE 5
REQUESTED VARIANCES:
TITLE 5: (NONE)
YARMOUTH BOARD OF HEALTH REGULATIONS: (ONE)
REGULATION 3: LOCATION
31 DISTANCES 4 LOCATION OF DISPOSAL FACILITY
- PROPOSED LEAGHIN6 FILED LE55 THAN 100' FROM
TOP OF COASTAL BANK (a7' PROPOSED 3' VARIANCE REQUIRED)
" MOTE: THE INFORMATION HEREON HAS BEEN
PREPARED ACCORDING TO THE REQUIREMENT5
OF TITLE 5 OF THE STATE ENVIRONMENTAL
CODE FOR SUBSURFACE DISPOSAL OF SANITARY
SEWAGE AND LOCAL BOARD OF HEALTH
REGULATIONS.
CEC 1998 - THIS DOCUMENT IS FOR THE EXCLUSIVE USE BY GEORGE ZOGRAFOS.
3) AFTER SEPTIC, TANK, PUMP CHAMBER t 6RA5E TRAP INSTALLED
VERIFY PIPE ELEVATIONS PRIOR TO 5ETTIN6 TANK
4)6LEARWNTER TEST AFTER ALL RM 5/ ALARMS INSTALLED
5) ALL TANKS TO BE WATER TESTED TO ASSURE WATER TI6HTN!£55.
2
IFlVBZT
E z
2 - 3' DIA.
REVISION
10.15
SHEET TIRE
L.£/aER
ALL
NOTED
FORGE MAINS
DATE
12/3Q/98
PRQIECT
()
1058
1035
I - AI
261 ROUTE 28 YARMOUTH, MASSACHUSETTS
DRAWING NO.
G14574.DW6
ALL
COMPANY, INC.
PROFESSIONAL ENGINEERS & LAND SURVEYORS
� PIS ON
1 GF. OF GONG. THRUST BLOGKINS
•
PUMP'a r
SWITCH
AT ALL BENDS IN FORGE MAIN
°
PUMP'oFF•
LEVELS
'�•
Su"R
9160
LIWIS) EXITING DBOX MUST REMAIN
q3O
LEVEL FOR 2'-0' BEFORE PITCHIN6
DOWN TO LEAGHIN6 FACILITY
12'1
LONGEST RUN = 22'
NOTE
SEPTIC TANK AND PUMP GHAMBER SHALL BE
OF KATERT16HT DE516N AND SHALL BE TE5TED
FOR WATER TIGHTNESS AFTER INSTALLATION A5
FOLLOWS: I. FILL TANKS
2.24 HOUR5 AFTER FILLIN6 MEASURE WATER LEVEL
3.45 HOURS AFTER FILLING REMEASURE WATER LEVEL
BENCHMARK - PK NAIL S SIDEWALK
ELEV. = 10.58 (N.G.V.D.) RUN RM 2D
PROPbSED VENT PI
ASSESSORS MAP 24
PARCEL K1
U
.1
PROP SED BIT.
CONC-BERM
?0 I
0 3 \
/ b
7
�' :✓.•.,.. s r, 3 0 ATO
/ PROPOSED D- BOX 4' syn CONCRETE O
\S
PROPOSED VEGETATIVE / ; T FF' •fR > `,1 , •` F Tq
SCREENING � / °'/ � �• �,,2 3 c� .y ' �xp� 0
4' HIGH x 5' 'v DE-
).:,
PROPOSED 2000 J,
GALLON PUMP
CHAMBER (H-216) „ ,RESE A 4 T p
-T-
Q.1
- m pp
1Q.1
PROPOSED 20 1 /
GALLON SEPTIC / " " R 1�."
TANK (H-20),/� '-75-
k, PROPOSED
RECHARGE 7,
/ FIELD A
PROPOSED 1500 It o4,
GALLON !GREASE TANK
(H-zo) l ' o io% �ti�s°jyc°o _ ..I / R > 501L REMOVAL NOTE
U
50
'�$x SlgeSopyGTS �•�k j „' ��: WTHIN 5' OF PROP05ED SOIL ABSORPTION SYSTEMS REMOVE
ALL MATERIAL DOWN TO THE NATURALLY 00CURIN6 SAND ("C")
r f� ter
r�,s f� r,ritA.
' FINISH COURSE, GLASS I TYPE 1-1 BIT. GONG.
2' BINDER COURSE, GLA% I TYPE 1-1 BIT. GONG.
PAVEMENT BASE Z SUBBASE MATERIAL SHALL BE COMPACTED
4' DENSE GRADED CRUSHED STONE (MI .03.0 TO 95% MAX DRY DENSITY (based upon AASHTO T180 Method D).
REMOVE TOP501L AND OR6ANIG MATTER PRIOR TO PLACEMENT
OF FILL MATERIALS
TYPICAL PAVEMENT 5ECTION OVER LEACHING FIELD
NO SCALE
V --
A
PROPOSED
RECHARGE
� ' FIELD B
v'
/ 2 / STRATi1M ( 3TO 4 FEET BELOW GRADE) AND REPLACE WITH GLEAN
PREVIOUS LOCATION SAND TO ELEVATION 11.0. FILL MATERIAL SHALL MEET THE 5PECICATION5
/ OF RAZED BUILDING OF NOTE 4 AT LEFT.
BOLlA1R['k9 ,,:. - / 7x3 y '
I HEREBY CERTIFY THAT THE EXIS77NG CONDITIONS SHOWN HEREON -
- - - / ARE LOCATED AS THEY EXIST ON THE GROUND AND THAT THE
PROPERTY LINES SHOWN HEREON REFLECT EXISTING PLANS AND
'• DEEDS OF RECORD.
6A OF
/t5-
71/ EDGE 91T
BERM' I _ _ --� _ ��� DATE' I� 130 b19 -P.L.
_� ..�� ..�� �fior32t
m�_ Lo_� CONT' RE'T�INING WALL (BY CHASE'S BROOK��'''''�'
/ /j Wq/UARD RAIL
/ 6 .0/NALL EL. 11.2 :; t INSPECTION` SSE
THE STATE ENVIRONMENTAL TITLE
DISPOSAL
MTEEM B S, REQUIRES IN5P INEER-YS)
OF THE SEWAGE DI BY DESIGN RN61N✓ffR.
INST I I ATION CA2ffRACJOR MUST NOTIFY THE DE516N EN61WER
LANPRIOR TO THE START OF INSTALLATION FOR DISO.%ION ON
40' Wx 34'L x O'-b"D LEAG44IN6 FIELD INSPECTIONS SGHEDU Es
0 AFTER EXCAVATION ! REMOVAL OF OLD FIELD
MIRAFI 50OX FILTER FABRIC SCALE: I"= 20' 2) AFTER PLACEMENT OF 19LL
OVER STONE ON LEAGHIN6 FIELD
2" LAYER OF I/8" TO 1/2'
WASHED STONE
4' DIA, SCH 40 PVC VENT PIPE
50' KSIRD SCREEN
1 I/2' VIA. PERF. SCH 40 PVC
O' - b' OF STONE
DEPTH TO ESTIMATED
MAXIM.M HIGH 6ROLWHATER
EST. MAX H16H 6ROUNDWATER
L= 416
OBSERVED 6ROLNIMATER
L= 42
SG HEMAT I G FLON PROFILE,
ALL INSTALLATIONS MUST CONFORM TO, THE MINIMUM REQUIREMENTS OF TITLE 5
REQUESTED VARIANCES:
TITLE 5: (NONE)
YARMOUTH BOARD OF HEALTH REGULATIONS: (ONE)
REGULATION 3: LOCATION
31 DISTANCES 4 LOCATION OF DISPOSAL FACILITY
- PROPOSED LEAGHIN6 FILED LE55 THAN 100' FROM
TOP OF COASTAL BANK (a7' PROPOSED 3' VARIANCE REQUIRED)
" MOTE: THE INFORMATION HEREON HAS BEEN
PREPARED ACCORDING TO THE REQUIREMENT5
OF TITLE 5 OF THE STATE ENVIRONMENTAL
CODE FOR SUBSURFACE DISPOSAL OF SANITARY
SEWAGE AND LOCAL BOARD OF HEALTH
REGULATIONS.
CEC 1998 - THIS DOCUMENT IS FOR THE EXCLUSIVE USE BY GEORGE ZOGRAFOS.
3) AFTER SEPTIC, TANK, PUMP CHAMBER t 6RA5E TRAP INSTALLED
VERIFY PIPE ELEVATIONS PRIOR TO 5ETTIN6 TANK
4)6LEARWNTER TEST AFTER ALL RM 5/ ALARMS INSTALLED
5) ALL TANKS TO BE WATER TESTED TO ASSURE WATER TI6HTN!£55.
N0.
DATE
REVISION
BY
SHEET TIRE
PRWECT "6145-T4.0
5ENA6E D 15P05AL 5Y5TEM- DETAI L5
NOTED
NEW SYSTEM
DATE
12/3Q/98
PRQIECT
DItA" BY MAP
Nj'-�� (/�^ }j�� �JL} }T''�'
6E
MR. GEORGE ZOV O5
CHECKED BY M
I - AI
261 ROUTE 28 YARMOUTH, MASSACHUSETTS
DRAWING NO.
G14574.DW6
- COASTAL ENGINEERING
COMPANY, INC.
PROFESSIONAL ENGINEERS & LAND SURVEYORS
SS-
260 CRANBERRY HIGHWAY
ORLEANS, MASS. 02653
(508) 255-6511
3OF SHEM