Loading...
HomeMy WebLinkAbout83-1523 - Sewage Disposal Systemxr a.. ma ».:r x a.,a:...vr. .w ,�- .s. .. e,r«.e x...f `ver .: e.. .--+nrrra✓.r: r. a+t«,wc.. v. +rtu ....., fix. .v. .i w.:+ax' Mu^k-�x'MY*�`++rxn BNlus:.y.. a.✓+"�.. s..N.. : s � {p u f I J11/22/99 SEPTIC TA NK DETAIL. goo=ca��oN DISTRIBUTION $ X Nor To 'scA SOIL TEST PIT ..DATA.0 ...DETAIL... LE L z EACHiNG DETAIL. NOT To SCALE NOT A Q TO SCA4 ILLE N0 F . o ounETs 5 _ _ f 25.25 PIT x PIT _ PEST 8' TEST _ _, : � NOTES- L.SEPTIC TAN4C SHALL BE STEEL .. , 5. INLET AND `OUTLET TEES TO BE CAST. IRON. FINISHED GRADE 5.8 5.4 SCNED: 4O PVC OR CAST -IN-PLACE GRD. EL. -.'GRD, EL, ,,REINFORCED CONCRETE. , CONCRETE. TEES TO BECENTEREDUNDER MANHOLE _ - , .. ., OLE COVER. 2.5.: ADJ. 2.5 ADJ _ REMOVABLE 2 . wALLs • GW. ;EL.- GW. EL. , 2. SEPTIC TANK TO WITHSTAND H 10 LOADING NOTES. , _ ,. COVER Q <` :: UNLESS UNDER PAVEMENT, I � ; A _ ., D VE EN , DRIVES OR '. i , - LOAM SANDY 10YR 2 LOAM SANDY fOYR 2 .--. .� _ TRAVELED WAYS , K".iEREIN H 20 LOADING . . _ — ` 4 $ . . 1 DIST. B X . WI C E „ SHALL APPLY. O TO WITHSTAND H 10 AIN 1 . LOAM SANDY 25YR 5 -, T . LOA1d SANDY 2.5YR 5 f c vWc eNeroox 13=, 14. ;` >UNLESS UNDER PAVEMENT DRIVES OR r ALL "PIP N N 3 E CONNECTIONS AND CONCRETE A W TRAVELED A R I . , . YS E N H M . AM „ND tOYR 5 6 AM Y YR WHE 20 LOADING LO SANDY / LO SANG iC 5J6 ``CONSTRUCTION SHALL 6c WATERTIGHT 8 2 2 29w {( -4. FILL ALL UNUSED KNOCKOUTS WITH 1' t f5e SHALL APPLY., EL-- 3.0 is " 33 , > __ " . , ... - 2-24 DIA `ClIN M T'. C.. ISH M .) MANHOLE COVERS _ - 33 MORTAR. ., . '. - 3 EL-- 3A 3 �` . � ' 8 2_ PROVIDE INLET TEE OR BAFFLE WHERE I T BROUGHT TO FINISH -GRADE 6 5 5 OUTLETS . 35 _ 's TEE 0 B_ UNDER ,, _ SLOPE E OF PIPE EXCEEDS 0.08 F1: OR , . %F F 1 M,N. LEACHING M;N, OPENING PLAN MEW A . , CHAFARFRS 4 :.4:..: ,' d o e a o o -e ae♦ IN PUMP VI= .A y d .+ o d T - ED .SYSTEM MED SAND.fOYR 6 6 'MED SAND IOYR 6 6 3 9't�p a a4 a'i. a'4 / I n a 2. , 3r FIRST.: TWO FEET OF PIPE OUT. DIST. 1 1 , �- ,OF o s . S 5 RAISE M.H W 80TTOM ON LEVEL f-- . LOAM d..SEED DISTURBED AREAS w � _ OX 0 6 6 ' MIN. $ 4 TO B TO BE LAID LEVEL BED RE 5 SEWER Bft1CK d ....STABLE :BASE... 2 CRUSHED ' 6 _ � MORTAR / .- 10 0 4. A PIPE N ALL E CON .CTION AN N I .. CROSS SECTION 5 AND CRETE : STONE BA MAX NORM WATER f2 SE 3 COMPACTED FILL 36".MAXIMUM, 12-M INIM EA AL TER LEVEL CONSTRUCTION SHALL BE WATERTIGHT. o 0 � T .��f� 0 0 0 0 PERFORATEDO* .. ' .+++++4r GENERAL NOTES: w.. 4 PVC as r PIPE o' rr r . • r,., -,•,r ,. .+++++4r GENERAL NOTES: f - THIS PLAN IS FOR DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL FACILITYONLY. - .++++++++++� 2. ALL CONSTRUCTION METHODS AND 1+++++tj +++�+♦ .. • • •• III Ill • • • • • • • • OF HEALTH REGULATIONS. ' 3. ALL PIPES LOCATED UNDER PAVEMENT OR TRAVELED WAY SHALL BE SCHEDULE 40 OR EQUAL 4. ITiERE` ARE NO KNOWN PRIVATE WELLS LOCATED WITHIN 150 FT. OF THE PROPOSED LEACHING FAMJTY NOR ANY KNOWN WELLS S PROPOSED WITHIN 15V OF ANY KNOWN LEACHING FACILITY. ' 5. WITHI"! LIMIT OF EXCAVATION REMOVE ALL TOPSO!L, SUBSOIL AND:OTHER , IMPERVIOUS MATERIAL, VI RE S10NS A NO. D TEDESCRIPTION GENERAL NOTES: f - THIS PLAN IS FOR DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL FACILITYONLY. 2. ALL CONSTRUCTION METHODS AND MATERIALS SHALL CONFORM TO MASS. D,E.P TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. ' 3. ALL PIPES LOCATED UNDER PAVEMENT OR TRAVELED WAY SHALL BE SCHEDULE 40 OR EQUAL 4. ITiERE` ARE NO KNOWN PRIVATE WELLS LOCATED WITHIN 150 FT. OF THE PROPOSED LEACHING FAMJTY NOR ANY KNOWN WELLS S PROPOSED WITHIN 15V OF ANY KNOWN LEACHING FACILITY. ' 5. WITHI"! LIMIT OF EXCAVATION REMOVE ALL TOPSO!L, SUBSOIL AND:OTHER , IMPERVIOUS MATERIAL, 6. REPLACE WITH CLEAN WASHED SAND OR OTHER CLEAN GRANULAR SOILS CONFOR4ftNG TO THE FOLLOWING SIEVE ANALYSIS: 10% (MAX) BY WT. SHALL PASS No. 5D S"EVE <10 X OF No. 4 SIEVE SHALL PASS No. 100 i5 % OF No. 4 SIEVE SHALL PASS No. 2DO UNIFORMITY COEFFICIENT •O No. 4 SIEVE </-6.0 7. EXISTING UTILITIES WHERE SHOWN IN THE DRAWINGS ARE APPROXIMATE. :THE CONTRACTOR SHALL BE RESPON— SIDLE FOR PROPERLY LOCATING AND COORDINATING THE PROPOSED CON— STRUCTION :ACTIVITY WITH DtG-SAFE AND THE APPLICABLE UTILITY COMPANY AND MAINTAINING THE EXISTING UTILITY SYSTEM IN SERVICE. DIG—SAFE SHALL BE NOTIFIED PER THE STATE OF MASSACHUSETTS STATUTE CHAPTER 82. SECTION 409 AT TEL <i-888-344-7233.`THE _ ENGINEER DOES NOT GUARANTEE THEIR ACCURACY OR THAT ALL UTILITIES AND SUBSURFACE STRUCTURES ARE SHOWN. LOCATIONS AND ' ELEVATIONS OF UNDERGROUND UTILITIES TAKEN FROM RECORD PLANS. THE CONTRACTOR SHALL VERIFY SIZE, -- LOCATION AND INVERTS OF UTILITIES AND STRUCTURES AS REQUIRED PRIOR TO THE START OF CONSTRUCTION. 8. THIS SYSTEM IS NOT DESIGNED FOR THE USE OF A GARBAGEGRINDER. A GARBAGE GRINDER IS NOT RECOMMENDED DUE TO RECOGNIZED ADVERSE IMPACTS TO THE LEACHING FACILITY 9 ' j 1 jhe BSC Group, Inc I y, X657 ROUTE 28, (UNIT 6) WEST -YARMOUTH, MA 02673 (508) 778-8919 PROJECT TITLE: SEWAGE DISPOSAL' SYSTEM DESIGN T4 ACCOMPANY NO.i. FILING LOT 3 ' PAWKANNAVA'KUT DRIVE S.' YAR OU TH PREPARED FOR:; BOSWORTH ASSOCIATES P.O.. BOX 685 1645 FALMOUTH ROAD, UNIT C CENTERVILLE MA 02632 DATE:. JULY 12.-2000 COMP./DESIGN:- K. HEALY CHECK: D. CRISPIN DRAWN: K. HEALY FIELD: P.H. / A.D. FILE NO. 8188—SEP.DWG DING N0. 5179-08 SHEET .1 OF .1 JOB N0. 4-8188.00