Loading...
HomeMy WebLinkAbout83-1567 - Septic Design20 FT. MINIMUM FROM CELLAR TOP OF FOUNDATION 10 FT. MINIMUM FROM SLAB OR CRAWL SPACE ELEV. 10 FT. MINIMUM CONCRETE COVERS 4• SCHEDULE 40 PVC PIPE MIN. PITCH 1/8" PER FT. , 4" CAST IRON PIPE HORIZ TEXTURE COLOR MOTT. OTHER MJNMU PIITCHOR EQ1/4) A LOAMY SAND 10YR4/4 NO ROOTS PER FTM B LOAMY SAND 10YR7/8 10YR6/6 ROOTS 23-120 FLOW LINE 2.5Y6/4 -ELEV. = 102.1010" -T IN. -2 -�1 ELEV. _ _101_55_ LEVEL ELEV. GAS ELEV. _ _10?•'�2 - 6" SUMP ELEV. 101 2_5_ BAFFLE DISTRIBUTION ELEV. _ V BOX _tm.03-7-/ OUTLET (TO BE PLACED ON FIRM BASE) TO BE WATER TESTED 1TEE 4 INCHES 19 INCHES 1500 GALLON IF MORE THAN ONE OUTLET 24 INCHES (TO BE PLACED ON FIRM BASE) 29 INCHES SEPTIC TANK 34 3/4" TO 1 1/2" CLEAN - DOUBLE WASHED STONE FREE OF FINES & SILT SEWAGE DISPOSAL SYSTEM PROFlLE NOT TO SCALE a7 ' LNcHMA NAk U_POL£ 250/5 ELEVA770N= 100.00' \ (ASSUMED) x 98.4 , k� .0 V� Px 99.5^ / �'Noeo�� 0 CLEAN SAND LOAM AND SEED SOIL TEST DATE OF SOIL TEST JULY 312001 SOIL TEST DONE BY �WEET�,ER ENGINEERING WITNESSED BY-L-J&LKEEN OBSERVATION HOLE 1 ELEV.=-!-(?2-so OBSERVATION HOLE 2 ELEV.-. 02.90 PFRCOLAT ON RATE -< 2- MIN./INCH AT 47__ INCHES PERCOLATION RATE <--L- - MIN./INCH IN C HORIZON 2" LAYER OF 1/8" TO 1/2" WASHED STONE VENT 102.28 MIN. NOT REQUIRED z 1 CU. FT. OF CONCRETE ANCHOR 0 10't l ELEV. = 100.20 DEPTH HORIZ TEXTURE COLOR MOTT. OTHER 0-8 A LOAMY SAND 10YR4/4 NO ROOTS 8-23 B LOAMY SAND 10YR7/8 10YR6/6 ROOTS 23-120 Cl FINE SAND 2.5Y8/2 2.5Y6/4 4 HIGH CAPA CITY NFILTRRATORS WTH 11' X 36' X 100 TRENCH FORMATION '0 SOIL ABSORPTION n WELL M1W 29 WATER ENCOUNTERED AT __1OB_ ELEV. = 9150 ZONE A INDEX 6.3 SYSTEM (SAS) ADJUST 1.7 USGS PROBABLE WATER TABLE ELEV. =95.20 OBSERVED WATER TABLE (7/31/2001) ELEV. = 91 BOTTOM OF TEST HOLE ELEV. _ _8200 _ U_POL£ 250/6 �\ i X 102.8 ool-x 103.8 LEGEND: EXISTING SPOT ELEVATION 00,0 EXISTING CONTOUR----00---- FINAL SPOT ELEVATION FINAL CONTOUR SOIL TEST LOCATION UTILITY POLE -0- TOWN WATER -W � CATCH BASIN GAS LINE Y - CLEAN OUT f CESSPOOL C.P. Q eUCk 1S�gNp �NSt.OW GRAY Y cyNP�SE LOCUS DEPTH HORIZ TEXTURE COLOR MOTT. OTHER 0-10 A LOAMY SAND 10YR4/2 NO ROOTS 10-28 B LOAMY SAND 10YR6/6 ROOTS 28-12( Cl MEDIUM SAND 2.5Y6/4 WATER ENCOUNTERED AT 113" ELEV. . 93.48_ DESIGN CALCULATIONS 3 NUMBER OF BEDROOMS GARBAGE DISPOSAL UNIT TOTAL ESTIMATED FLOW ( 110 GAL/BR•/DAY X _3._ SR.) _-30_ GAL./DAY REQUIRED SEPTIC TANK CAPACITY GAL. ACTUAL SIZE OF SEPTIC TANK 15_0_0_ GAL. SOIL CLASSIFICATION -I-- DESIGN PERCOLATION RATE :5-b- MIN./W. EFFLUENT LOADING RATE _4.7� GAL./DAY/S.F. LEACHING AREA --000 SO. FT. (1104)+(45=10/12) LEACHING CAPACITY (AREA X RATE) .2.24 GAL./DAY 449.00 X 0.74 RESERVE LEACHING CAPACITY M7.24 GAL./DAY NOTES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE 5 AND THE TOWN OF ___Y&MQVM-- RULES AND REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE. 2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO W THIN 6" OF FINISHED GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM $HAL. BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WTHIN 10 FT. OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS. 4. ANY MASONRY UNITS USED TO BRING COVERS TO GRADE SHALL BE MORTARED IN PLACE. 5, NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLCANT IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 6. UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR IS TO CALL 'DIG -SAFE" AT 1-888-344-7233 AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE. 7. CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION IS TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER IMMEDIATELY. S. PARCEL IS IN FLOOD ZONE C 9. LOT IS SHOWN ON ASSESSORS MAP 49 AS PARCEL 32 10. ALL DISTURBED AREAS ARE TO BE REVEGETATED. 11. ALL UNSUITABLE MATERIAL SHALL BE REMOVED FROM UNDER AND FOR A MINIMUM OF 5' AROUND SOIL ABSORPTION SYSTEM AND BE REPLACED WITH SAND AS SPECIFIED IN 310 CMR 15.255:(3), 12. VARIANCES TO YARMOUTH REGULATIONS: A. SOIL ABSORPTION SYSTEM LESS THAN 100' FROM WETLAND. B. RESERVE AREA LESS THAN 100' FROM WETLAND. APPROVED: BOARD OF HEALTH DATE AGENT PROPOSED SEPTIC DESIGN FOR STEVE POT7ERS OG. IAT 09, 994 100 PLBIL20 P0.15 31 ITAUS' 1 ROAD, r. YAPMOUTiL WM. SF'EL"15L'R LXGn&T=G 235 GREAT WESTERN ROAD 508- P. 0. BOX 713 i98-3922 SOUTH DENNIS, MASS. 0266C DATE SEPT 5, 2001 SCALE 1 " = 2( REV SED JOB N0. 5181-00 11 LOCATION MAP REVISED I SHEET 1 OF"