Loading...
HomeMy WebLinkAbout83-1576 - Site PlanN /F FREEMAN RECOMMEND TWO 6" INSPECTION PORTS WITH COVERS. BELIEVED TO BE OLD TH2 10/20/99 WATER @ 1.41 BENCH MARK --TOP & CENTER OF WOOD STAKE= 7.60 NGVD29 C.B. END , 7.3 7.3 N /F EFSTATHIOU 7.6 7.60 S 77431'4p• LOCUS IS IN AN R=25 ZONING DISTRICT, AND APPEARS SUBJECT TO CONSTRUCTION YARDS OF: FRONT YARD 30' SIDE YARD 15' REAR YARD 20' ACTUAL ZONING DETERMINATIONS MUST BE MADE BY TOWN ZONING OFFICAL. N/F CONNELLY 23' . t ON f' PROPOSED 0 ru ToP F 'DWELL/ NG DROOM 24' <�un12.5 ....:.....:24' 11.3 5.8 PORCH k 6.3 � .;.5.8 rl / 10 o- 1 OIh I - 5. \�36' • 5.2 6.8 j.7 6.4 '8-8 WJ 6.7 7 ELECTRIC BOX •-L,-71 6 125.Op, N 3 E 7.31'40• W Qo�l 53 I 4.7 41 66.26 HIGH POINT=6.8 � 6.42 0A D -- 6.60 BENCH MARK --TOP SPIKE SET IN PAVEMENT = 6.42 NGVD29 (4.5' W. OF RANGE LINE REAR OF HOUSE 5) uN I 5.9 C.B. END- 6.7 NOTES vvu IY V. IVI-4� Roy3.dwg 1. LOCUS IS A.M. 14, PARCEL 37. 2. ELEVATIONS SHOWN ARE NGVD29 BASED UPON FIRM BENCH RM24. 3. LOCUS IS IN FLOOD ZONE Al2 (EL.10) ON FIRM DATED JULY 2, 1992. 4. ALL PIPES TO BE 4" SCH 40, AND PITCHED AT 1/4" PER FOOT. (UNLESS NOTED) 5. MUNICIPAL WATER IS AVAILABLE. LOTS WITHIN 100' ARE ON TOWN WATER. 6. COMPONENTS TO BE AASHTO H-10, UNLESS NOTED. 7. INLET TEE TO PROJECT DOWN 13", OUTLET TEE DOWN 14". 8. IF TWO OR MORE LINES, WATER TEST D -BOX FOR EQUAL FLOW D -BOX EXIT PIPES TO BE LEVEL FOR FIRST TWO FEET. 9. DEPTH OF COMPONENTS NOT TO EXCEED 3', OR VENTING MUST BE PROVIDED. BUILD UP COVERS TO WITHIN 1' OF GRADE. MORTAR CHIMNEYS IN PLACE. ONE COVER OF TANK TO BE WITHIN 6" OF GRADE. 10. STONE TO BE DOUBLE WASHED 3/4 TO 1 1/2" WITH 2" MIN. 1/8 TO 1/2" PEA STONE ON TOP. 11. IF UNSUITABLE SOILS, OR SOILS DIFFERING FROM THE SOIL LOG ARE FOUND, CONTACT THE BOARD OF HEALTH, OR R.J. CADILLAC. 12. IF AN OVERDIG IS CALLED FOR BELOW, FILL MATERIAL FOR 5' AROUND AND UNDER LEACHING IS TO BE CLEAN GRANULAR SAND MEETING SPECIFICATIONS OF 310 CMR 15.255(3). 13. ALL CONSTRUCTION TO MEET TITLE 5 AND LOCAL REGULATIONS. I 12.75 T1PP2. House slab 6.1Top Foundation rt9.20 sed S=3/8"/ft 12" cover Prop. overt 8.90 2000 Gal: Proposed Septic Tanb TEST HOLE 1 DEPTH (inches) ELEV.(feet) LEGEND TH 1 TEST HOLE LOCATION, NUMBER -W- PROPOSED WATER SERVICE -E- UNDERGROUND ELECTRIC MARKINGS 9.5 x 8,7 EXISTING & PROPOSED ELEVATIONS ('X' MARKS POINT) �6-` EXISTING CONTOUR -8�-- PROPOSED CONTOUR X - FENCE (IF SHOWN, NOT ALL SHOWN) QTREE (IF SHOWN, NOT ALL SHOWN) uN I 5.9 C.B. END- 6.7 NOTES vvu IY V. IVI-4� Roy3.dwg 1. LOCUS IS A.M. 14, PARCEL 37. 2. ELEVATIONS SHOWN ARE NGVD29 BASED UPON FIRM BENCH RM24. 3. LOCUS IS IN FLOOD ZONE Al2 (EL.10) ON FIRM DATED JULY 2, 1992. 4. ALL PIPES TO BE 4" SCH 40, AND PITCHED AT 1/4" PER FOOT. (UNLESS NOTED) 5. MUNICIPAL WATER IS AVAILABLE. LOTS WITHIN 100' ARE ON TOWN WATER. 6. COMPONENTS TO BE AASHTO H-10, UNLESS NOTED. 7. INLET TEE TO PROJECT DOWN 13", OUTLET TEE DOWN 14". 8. IF TWO OR MORE LINES, WATER TEST D -BOX FOR EQUAL FLOW D -BOX EXIT PIPES TO BE LEVEL FOR FIRST TWO FEET. 9. DEPTH OF COMPONENTS NOT TO EXCEED 3', OR VENTING MUST BE PROVIDED. BUILD UP COVERS TO WITHIN 1' OF GRADE. MORTAR CHIMNEYS IN PLACE. ONE COVER OF TANK TO BE WITHIN 6" OF GRADE. 10. STONE TO BE DOUBLE WASHED 3/4 TO 1 1/2" WITH 2" MIN. 1/8 TO 1/2" PEA STONE ON TOP. 11. IF UNSUITABLE SOILS, OR SOILS DIFFERING FROM THE SOIL LOG ARE FOUND, CONTACT THE BOARD OF HEALTH, OR R.J. CADILLAC. 12. IF AN OVERDIG IS CALLED FOR BELOW, FILL MATERIAL FOR 5' AROUND AND UNDER LEACHING IS TO BE CLEAN GRANULAR SAND MEETING SPECIFICATIONS OF 310 CMR 15.255(3). 13. ALL CONSTRUCTION TO MEET TITLE 5 AND LOCAL REGULATIONS. I 12.75 T1PP2. House slab 6.1Top Foundation rt9.20 sed S=3/8"/ft 12" cover Prop. overt 8.90 2000 Gal: Proposed Septic Tanb TEST HOLE 1 DEPTH (inches) ELEV.(feet) A layer 10yr 4/2 loamy sand B layer 10yr 4/6 loamy sand C layer 10yr 6/6 fine sand _observed water 6.7 4.2 T6„ 120" L 1-3.3 Invert 8.47 Invert $.30 7.8 6" Stone cr compact Proposed Proposed � 5.0' Bottom Level TEST HOLE 2 �---- 10 ---f -- 8' -� 1 � (---0' EL 2.8 NGVD29 DEPTH (inches) ELEV.(feet) ,L 1.45' Adjustment Provided DESIGN DATA 0 TEST HOLE DATE: October 23, 2001 6" PERFORMED BY: Ron Cadillac, Soil Evaluator WITNESSED BY: Charlotte Stiefiel, RS PERC RATE: <2'-00"/inch (C layer) LEACH AREA SOIL SURVEY(1993): Carver coarse sand No GEOLOGIC MAP(1986): Harwich outwash plain deposits 30" REQUIRED CAPACITY: 440 GPD V Invert 8.65 SEPTIC TANK: °' 48.. n Use Gas Baffle Invert 8.30 6 CONTACTOR 100'S 83TTO4a LEACHING APEA: S=1 /4"/ft+ Proposed 8.8 TOP PEA STONE 67 A layer 10yr 4/2 loamy sand B layer 10yr 4/6 loamy sand C layer 10yr 6/6 fine sand _observed water 6.7 4.2 T6„ 120" L 1-3.3 Invert 8.47 Invert $.30 7.8 6" Stone cr compact Proposed Proposed � 5.0' Bottom Level TEST HOLE 2 �---- 10 ---f -- 8' -� 1 � (---0' EL 2.8 NGVD29 DEPTH (inches) ELEV.(feet) ,L 1.45' Adjustment Provided DESIGN DATA < is within 300' 0 of sal rp of Solt water 4" OBSERVED WATER=1.35 N/F BEDROOMS: 4 LEACH AREA 9" HADDAD GARBAGE GRINDER: No REQUIRED CAPACITY: 440 GPD USE 6 CONTACTOR 100'S SET WITH SEPTIC TANK: 1500 GAL. 4' OF STONE ON THE SIDES, AND 2' 32 83TTO4a LEACHING APEA: 542.6 SF OF STONE ON THE ENDS, AND WITH [49.5' x 11'] - 1.9 S.F.• A 6'-6" SPACE IN THE CENTER FOR LEACHING s" E LEACHING AREA: AREA: 60.5 SF THE D -BOX, AS SHOWN. RECOMMEND [2(49.5+ 11') x DEEP)] TWO 6" INSPECTION PORTS WITH DESIGN CAPACITY: 446 GPD COVERS JUST BELOW GRADE. 69" [(542.6 SF + 60.5 SF) X .74 GPD,/SF] 55' REMOVAL 'AREA OF D -BOX SUBTRACTED DO 5' UNDER AND ALL AROUND RE- MOVAL DOWN 32" + 120" ELECTRIC BOX THIS PLAN IS A VALID COPY ONLY IF IT BEARS AN ORIGINAL RED STAMP AND SIGNATURE. HEALTH AGENT APPROVAL DATE A loyer 10yr 2/2 7.1 loom y sand E layer 10yr 4/1 loamy sand B layer10yr -4/6-- .. ..-_.. loamy sand 4.4 C layer 10yr 6/6 medium sand observed water - 1.35 TO MED. SAND. -2•g SITE PLAN FOR ELZEAR & PATRICIA ROY LOT 291 8 QUAIL ROAD, WEST YARMOUTH, MA DECEMBER 20, 2001 SCALE: 1"=20' RONALD J. CADILLAC, PLS, RS PROFESSIONAL LAND SURVEYOR & REGISTERED SANITARIAN P.O. BOX 258 WEST YARMOUTH, MA 02673 (508) 775-9700 2001 BY R.J. CADILLAC PAGE 1 OF 1