HomeMy WebLinkAbout83-1595BENCHMARK 4" SCHEDULE 40 PVC PIPE
TOP .OF FOUNDATION 20 FT. MINIMUM FROM CELLAR MIN. PITCH 1/8" PER FT. -
_9._04 10 FT. MINIMUM 10 FT. MINIMUM FROM SLAB OR CRAWV.
L SPACE
ELEV. = 2" PRESSURE PIPE
(ASSUMED) 150 PSI MINIMUM ES_.90
CONCRETE -7 - -- I
COVERS 24" MANHOLE
CLEAN SAND
10.00 MAX.
8.93
2" LAYER OF
1/8" TO 1/2"
WASHED STONE VENT
9.68 MIN.
Z I 1 CU. FT. OF
�i CONCRETE
. ! ANCHOR
m
to
ELEV.
2.50
4" CAST IRON PIPE
(OR EQUAL) MINIMUM
I -
COLOR MOTT.
OTHER
2'0"
° ° °
°
INSIDE FACE IS TO BE
10YR3/3 NO
ROOTS
2-22
B
FT.
10YR5/8
ROOTS
- ; 0�
ASPHALT
COATED AND
10YR6/8
NOTES:
6X1 1 30,962 LBS.
PITCH 1 /4" PER
ABEL A1600 I ER
LEVEL
ELEV. 6" SUMP 8.53
ELEV. _
° - _ =
,. 7_60
ELEV. _ _ HAVE
6 ML. POLY ATTACHED
F
1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P.
WEIGHT OF 12" CONCRETE
WEIGHT OF WATER IN SUMP
12" CONCRETE
______
8.17X4.42X0.83X625
BOTTOM OF TEST HOLE ELEV. = 0.42 _
REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE.
ELEV.
3_
REVISED
FLOW LINE
25080 + 6750 - 30952 688 LBS
ELEV. AT INVERT INLET
8'70
PUMP CHAMBER CALCULATIONS:
LEGEND:
GARBAGE DISPOSAL UNIT
NO
3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF
SEWAGE
10"
a.®o _
3-55
REQUIRED FLOW PER CYCLE .25 X __i3_Q = � ' GAL./CYCLE
DISTRIBUTION ELEV. =
TOTAL ESTIMATED FLOW
(110 GAL/BR./DAY X 3 BR.)
330 GAL./DAY
STEEL STRENGTH
TO BE REPLUMBED AS
ELEV. 8_5_4 __
TMIN.
I
VOLUME PER CYCLE 82.5 GAL/CYCLE /7.48 CAL./CU. FT. = 11.03_ CU. FT./CYCLE
FINAL SPOT ELEVATION 00.
3/8" DRILL &
BOX
4 HIGHCAPACITY
STONE INFILTRATORS
? 4'�
Fy 60,000 PSI
CONCRETE STRENGTH
NEEDED BY LICENSED
1_90-
1.40_
GAS
BAFFLE
N
CAPACITY OF SEPTIC TANK
HOLE
TO BE WATER TESTED
11 X34 X 10 TRENCH FORMATION
WELL MIW 29
TANK
3,400 PSI
PLUMBER
ELEV. _ _6.25 -
ELEV. _ _8_00
o
(TO BE PLACED ON FIRM BASE)
3/4" TO 1. 1/2"
SOIL ABSORPTION
n ZONE A
INDEX 9.7
7-
14�
DISCHARGE 11,_51_ CU. FT. / 36.11 CU.FT./FT. _ _0.32 FT. (1000 G.S.T.)
_
STORAGE CAPACITY (-Z34L GAL/DAV /7.46 GAL./CU.FT./36.11 CU.FT./FT. _ _1_�_
OUTLET
-- -'
CHECK
VALVE WASHED STONE
SYSTEM (SAS)
ADJUST 27
ELEV. a�
_l•-22- REQUIRED 2.00 PROVIDED
(10\
CATCH BASIN V�7
LIQUID
A.74_ GAL./DAY/S.F.
1/2 ADJUST
14"FRT
FF
(TO BE PLACED ON FIRM BASE)
14 INCHES
I
SOIL TEST
DATE OF SOIL TEST�14�ggg___
SOIL TEST DONE BY ,SV CT.$Lj ENGINLEgING
WITNESSED BY
OBSERVATION HOLE 1 ELEV.-_ 6_25 _
PERCOLATION RATE < 2 MIN./INCH AT _ 36 INCHES
DEPTH
HORIZ
I TEXTURE
COLOR MOTT.
OTHER
0-5
Ap
LOAMY SAND
10YR3/3 NO
ROOTS
2-22
B
LOAMY SAND
10YR5/8
ROOTS
22-70
C
MEDIUM SAND
10YR6/8
NOTES:
[y
1
T
PUMP
CHAMBER
Rl
U
LOT 27
SHED AREA=9,000E S.F.
.o o
0
iso
TE C
VEN
18 00'
_
PUMP SWITCHES DETAIL
ALARM ON 3.90
PUMP ON 3.55
13 13/16' 1.15'
PUMP OFF3.23
110' 240 0.833
10 FT. OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE
USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS.
18. THE HAYBALE WORKLIMITIS TO BE PLACED BEFORE ANY OTHER 4. ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL
WORK COMMENCES ON SITE. BE MORTARED IN PLACE.
19. THE CONTRACTOR IS TO SUPPLY AND PLACE ANY SHORING WHERE 5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH
_ ,NEEDED TO PROTECT HU!LD!NG AND APUTTNG PROPERTY. _ DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO
20. VARIANCES TO TITLE 5 AND YARMOUTH REGULATIONS: OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY.
A. SOIL ABSORPTION SYSTEM LESS THAN 50' FROM WETLAND.(t00' TOWN) 6. UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR
IS TO CALL "DIG -SAFE" AT 1-888-344-7233 AT LEAST 72 HOURS
B. SOIL ABSORPTION SYSTEM LESS THAN 10' FROM LOT LINE. PRIOR TO COMMENCING WORK ON SITE.
C. SOIL ABSORPTION SYSTEM LESS THAN 5' ABOVE WATER TABLE. 7, CONTRACTOR IS -0 VER'EY GRADES AND ELEVATIONS AS WELL AS
D. USE OE ONLY HALF THE WATER TAB_E ADJUSTMENT. SITE CONDITIONS PR:OR TO COMMENCING WORK ON SITE. ANY VARIATION
E. SEPTIC TANK AND PUMP CHAMBER LESS THAN 10' FROM BUILDING. IS TO BE BROUGHT TO 7wE ATTENTION OF THE DESIGN ENGINEER
F. SEPTIC TANK AND PUMP CHAMBER LESS THAN 1C' FROM LOT LINE. IMMEDIATELY.
G. NO RESERVE AREA. 8. PARCEL IS IN FLOOD ZONE Ajj_j�E_LL.. 1j0)
P oC 9. LOT IS SHOWN ON ASSESSORS MAP __34___ AS PARCEL X219__
g2
10. PUMP
AND
ALARM E ON
11. ALARMISTOBE BOTH AUDIO AND VISUAL. CIRCUITS.
12. A ZABEL A1800 FILTER IS TO BE INSTALLED.
13. AN ELECTRIC PERMIT IS REQUIRED TO WIRE PUMP AND ALARM.
O 14. ALL UNSUITABLE MAT r'!AL SHALL BE REMOVED FROM UNDER AND
qZ FOR A MINIMUM 07 5' AROUND SOIL ABSORPTION SYSTEM AND BE
m0 REPLACED WITH MATERIAL AS SPECIFIED IN 310 CMR 15.255:(3).
_ „y ,r c.;, --i5. SEPTIC TANK AND PUMP CHAMBER ARE TO BE WATERPROOFED AT
Ylaa „ 1' 141r ", E MANUFACTURER.
r` 'F°i' 1E EXISTING CESSPOOLS ARE TO BE PUMPED AND REMOVED.
vruox
. =1 7 APDISTURBED AREAS ARE GE
PROVED: OARD OF HEALTH
DATE
AGENT
5 FEET
5 FEET
19 INCHES
24 INCHES
2000 GALLON
MYERS MHV 4 OR 5
PUMP (OR EQUAL)
INUNDATION) CLEANOUTC.O.
1/2 USGS PROBABLE WATER TA13LE ELEV. = 3.60
USGS PROBABLE WATER TABLE ELEV. = 4•�_
WALL SCHEMATIC
WATER ENCOUNTERED AT 48"__ ELEV. = 2.25
LOC
LOT 27, 70 BREEZY POINT ROAD
SOUTH YARMOUTH MASS
6 FEET
34 INCHES
SEPTIC TANK
CHAMBER g" CONCRETE
(H-20)
Z_25
(SEE CONSTRUCTION PLANS)
DESIGN CALCULATIONS
NOTES:
6X1 1 30,962 LBS.
9X5.28XSX64
18,144 LBS
SCALE 1 " = 20'
` WEIGHT OF TANK PER MANUFACTURER 25,080 LBS.
OBSERVED WATER TABLE (2/14/02) ELEV. =
14.500 LBS
1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P.
WEIGHT OF 12" CONCRETE
WEIGHT OF WATER IN SUMP
12" CONCRETE
5X10XIX135 8,750 LBS.
8.17X4.42X0.83X625
BOTTOM OF TEST HOLE ELEV. = 0.42 _
REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE.
NUMBER OF BEDROOMS
3_
REVISED
2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO
25080 + 6750 - 30952 688 LBS
ELEV. AT INVERT INLET
5.90
PUMP CHAMBER CALCULATIONS:
LEGEND:
GARBAGE DISPOSAL UNIT
NO
3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF
SEWAGE
ELEV. AT ALARM ON
DISPOSAL SYSTEM PROFILE ELEV. AT PUMP ON
a.®o _
3-55
REQUIRED FLOW PER CYCLE .25 X __i3_Q = � ' GAL./CYCLE
EXISTING SPOT ELEVATION 00,0
EXISTING CONTOUR ----00----
TOTAL ESTIMATED FLOW
(110 GAL/BR./DAY X 3 BR.)
330 GAL./DAY
NOT TO SCALE
ELEV. AT PUMP OFF
_3.23
VOLUME PER CYCLE 82.5 GAL/CYCLE /7.48 CAL./CU. FT. = 11.03_ CU. FT./CYCLE
FINAL SPOT ELEVATION 00.
REQUIRED SEPTIC TANK CAPACITY
ACTUAL SIZE OF SEPTIC TANK
880 GAL.
X009 GAL.
BOTTOM OF INSIDE PUMP CHAMBER
1_90-
1.40_
VOLUME OF WATER IN PIPE 3.14 X 0.00694 X FT,. 0.48_ CU. FT.
FINAL CONTOUR
SOIL TEST
CAPACITY OF SEPTIC TANK
�$_ GAL.
CAPACITY
OF SEPTIC
TANK
BOTTOM OF OUTSIDE PUKW CHAMBER
TOTAL MINIMUM VOLUME PER CYCLE _ 11M CU. FT,
LOCATION
SOIL CLASSIFICATION
5X10X(5.33- 1_00
)X7.48 = 1819__
GALLONS
DISCHARGE 11,_51_ CU. FT. / 36.11 CU.FT./FT. _ _0.32 FT. (1000 G.S.T.)
_
STORAGE CAPACITY (-Z34L GAL/DAV /7.46 GAL./CU.FT./36.11 CU.FT./FT. _ _1_�_
UTILITY POLE -0
FT. TOWN WATER �W�W
DESIGN PERCOLATION RATE
<_ ',f_ MW./IN.
_l•-22- REQUIRED 2.00 PROVIDED
(10\
CATCH BASIN V�7
EFFLUENT LOADING RATE
LEACHING ARCA
A.74_ GAL./DAY/S.F.
[y
1
T
PUMP
CHAMBER
Rl
U
LOT 27
SHED AREA=9,000E S.F.
.o o
0
iso
TE C
VEN
18 00'
_
PUMP SWITCHES DETAIL
ALARM ON 3.90
PUMP ON 3.55
13 13/16' 1.15'
PUMP OFF3.23
110' 240 0.833
10 FT. OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE
USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS.
18. THE HAYBALE WORKLIMITIS TO BE PLACED BEFORE ANY OTHER 4. ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL
WORK COMMENCES ON SITE. BE MORTARED IN PLACE.
19. THE CONTRACTOR IS TO SUPPLY AND PLACE ANY SHORING WHERE 5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH
_ ,NEEDED TO PROTECT HU!LD!NG AND APUTTNG PROPERTY. _ DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO
20. VARIANCES TO TITLE 5 AND YARMOUTH REGULATIONS: OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY.
A. SOIL ABSORPTION SYSTEM LESS THAN 50' FROM WETLAND.(t00' TOWN) 6. UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR
IS TO CALL "DIG -SAFE" AT 1-888-344-7233 AT LEAST 72 HOURS
B. SOIL ABSORPTION SYSTEM LESS THAN 10' FROM LOT LINE. PRIOR TO COMMENCING WORK ON SITE.
C. SOIL ABSORPTION SYSTEM LESS THAN 5' ABOVE WATER TABLE. 7, CONTRACTOR IS -0 VER'EY GRADES AND ELEVATIONS AS WELL AS
D. USE OE ONLY HALF THE WATER TAB_E ADJUSTMENT. SITE CONDITIONS PR:OR TO COMMENCING WORK ON SITE. ANY VARIATION
E. SEPTIC TANK AND PUMP CHAMBER LESS THAN 10' FROM BUILDING. IS TO BE BROUGHT TO 7wE ATTENTION OF THE DESIGN ENGINEER
F. SEPTIC TANK AND PUMP CHAMBER LESS THAN 1C' FROM LOT LINE. IMMEDIATELY.
G. NO RESERVE AREA. 8. PARCEL IS IN FLOOD ZONE Ajj_j�E_LL.. 1j0)
P oC 9. LOT IS SHOWN ON ASSESSORS MAP __34___ AS PARCEL X219__
g2
10. PUMP
AND
ALARM E ON
11. ALARMISTOBE BOTH AUDIO AND VISUAL. CIRCUITS.
12. A ZABEL A1800 FILTER IS TO BE INSTALLED.
13. AN ELECTRIC PERMIT IS REQUIRED TO WIRE PUMP AND ALARM.
O 14. ALL UNSUITABLE MAT r'!AL SHALL BE REMOVED FROM UNDER AND
qZ FOR A MINIMUM 07 5' AROUND SOIL ABSORPTION SYSTEM AND BE
m0 REPLACED WITH MATERIAL AS SPECIFIED IN 310 CMR 15.255:(3).
_ „y ,r c.;, --i5. SEPTIC TANK AND PUMP CHAMBER ARE TO BE WATERPROOFED AT
Ylaa „ 1' 141r ", E MANUFACTURER.
r` 'F°i' 1E EXISTING CESSPOOLS ARE TO BE PUMPED AND REMOVED.
vruox
. =1 7 APDISTURBED AREAS ARE GE
PROVED: OARD OF HEALTH
DATE
AGENT
CESSPOOL
O C.P.
11X34)+(45X2X70/12) =�� S0. FT.
BUOYANCY CALCULATIONS:
INUNDATION) CLEANOUTC.O.
LEACHING CAPACITY (AREA X RATE) 33228 GAL./DAY
(FULL
LOC
LOT 27, 70 BREEZY POINT ROAD
SOUTH YARMOUTH MASS
449.00 X 0.74
2000 GALLON SEPTIC TANK (H-20)
1000 GALLON PUMP CHAMBER
(H-20)
RESERVE LEACHING CAPACITY NONE GAL./DAY
W DISPLACED
WEIGHT 4
WEIGHTDISPLACED
NOTES:
6X1 1 30,962 LBS.
9X5.28XSX64
18,144 LBS
SCALE 1 " = 20'
` WEIGHT OF TANK PER MANUFACTURER 25,080 LBS.
WEIGHT OF TANK PER MANUFACTURER
14.500 LBS
1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P.
WEIGHT OF 12" CONCRETE
WEIGHT OF WATER IN SUMP
TITLE 5 AND THE TOWN OF __YARMQUM ___ RULES AND
5X10XIX135 8,750 LBS.
8.17X4.42X0.83X625
1,873 LBS
REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE.
EXCESS WEIGHT TO OFFSET FLOTATION
WEIGHT OF 6" CONCRETE
REVISED
2. ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO
25080 + 6750 - 30952 688 LBS
8.170.42X0.5XI35
2437 LBS.
WITHIN 6" OF FINISHED GRADE.
EXCESS WEIGHT TO OFFSET FLOTATION
3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF
14500+1873+2437-18144
666 LBS
WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN
[y
1
T
PUMP
CHAMBER
Rl
U
LOT 27
SHED AREA=9,000E S.F.
.o o
0
iso
TE C
VEN
18 00'
_
PUMP SWITCHES DETAIL
ALARM ON 3.90
PUMP ON 3.55
13 13/16' 1.15'
PUMP OFF3.23
110' 240 0.833
10 FT. OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE
USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS.
18. THE HAYBALE WORKLIMITIS TO BE PLACED BEFORE ANY OTHER 4. ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL
WORK COMMENCES ON SITE. BE MORTARED IN PLACE.
19. THE CONTRACTOR IS TO SUPPLY AND PLACE ANY SHORING WHERE 5. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH
_ ,NEEDED TO PROTECT HU!LD!NG AND APUTTNG PROPERTY. _ DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT IS TO
20. VARIANCES TO TITLE 5 AND YARMOUTH REGULATIONS: OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY.
A. SOIL ABSORPTION SYSTEM LESS THAN 50' FROM WETLAND.(t00' TOWN) 6. UTILITIES SHOWN ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR
IS TO CALL "DIG -SAFE" AT 1-888-344-7233 AT LEAST 72 HOURS
B. SOIL ABSORPTION SYSTEM LESS THAN 10' FROM LOT LINE. PRIOR TO COMMENCING WORK ON SITE.
C. SOIL ABSORPTION SYSTEM LESS THAN 5' ABOVE WATER TABLE. 7, CONTRACTOR IS -0 VER'EY GRADES AND ELEVATIONS AS WELL AS
D. USE OE ONLY HALF THE WATER TAB_E ADJUSTMENT. SITE CONDITIONS PR:OR TO COMMENCING WORK ON SITE. ANY VARIATION
E. SEPTIC TANK AND PUMP CHAMBER LESS THAN 10' FROM BUILDING. IS TO BE BROUGHT TO 7wE ATTENTION OF THE DESIGN ENGINEER
F. SEPTIC TANK AND PUMP CHAMBER LESS THAN 1C' FROM LOT LINE. IMMEDIATELY.
G. NO RESERVE AREA. 8. PARCEL IS IN FLOOD ZONE Ajj_j�E_LL.. 1j0)
P oC 9. LOT IS SHOWN ON ASSESSORS MAP __34___ AS PARCEL X219__
g2
10. PUMP
AND
ALARM E ON
11. ALARMISTOBE BOTH AUDIO AND VISUAL. CIRCUITS.
12. A ZABEL A1800 FILTER IS TO BE INSTALLED.
13. AN ELECTRIC PERMIT IS REQUIRED TO WIRE PUMP AND ALARM.
O 14. ALL UNSUITABLE MAT r'!AL SHALL BE REMOVED FROM UNDER AND
qZ FOR A MINIMUM 07 5' AROUND SOIL ABSORPTION SYSTEM AND BE
m0 REPLACED WITH MATERIAL AS SPECIFIED IN 310 CMR 15.255:(3).
_ „y ,r c.;, --i5. SEPTIC TANK AND PUMP CHAMBER ARE TO BE WATERPROOFED AT
Ylaa „ 1' 141r ", E MANUFACTURER.
r` 'F°i' 1E EXISTING CESSPOOLS ARE TO BE PUMPED AND REMOVED.
vruox
. =1 7 APDISTURBED AREAS ARE GE
PROVED: OARD OF HEALTH
DATE
AGENT
5344-OO.ON'0
$
ao�j� 2 WILLOW
rl LOCUS
o
-
PROPOSED SEPTIC DESIGN
FOR
ED KOWALSKI
LOC
LOT 27, 70 BREEZY POINT ROAD
SOUTH YARMOUTH MASS
Si3WEETSER ENGINEERING
235 GREAT WESTERN ROAD
508- P. 0. BOX 713
398-3922 SOUTH DENNIS, MASS. 02660
DAA M AR. 29, 2002
SCALE 1 " = 20'
JOB N0. 0344-00
REVISED 7
LOCATION MAP
REVISED
SHEET 1 OF 1
5344-OO.ON'0
BENCHMARK 20 FT. MINIMUM FROM CELLAR
TOP OF FOUNDATION 10 FT. MINIMUM FROM SLAB OR CRAWL SF
ELEV. = 9 _ 10 FT. MINIMUM 2" PRESSURE PIPE
(ASSUMED) 150 PSI MINIMUM -
CONCRETE --7
COVERS / 24" MANHOL
4" CAST IRON PIPE
2-501 I I POTION EQUAL)
1 /4PER FTM
LEV.
I NEEDED BYTO BE LLICENSEDUMeSI �EELEV =6_8.25_ .I UE IN. BAGAS
FFLE
BE PLACED ON FIRM BASE)
4" SCHEDULE 40 PVC PIPE
MIN. PITCH 1/8" PER FT.-
ELEV.
5.90
ELEV. = J6" SUMP LELEV.
_ &70_
DISTRIBUTION ELEV. _
3/B" DRILL BOX -&43_-/
- HOLE TO BE WATER TESTED
(TO BE PLACED ON FIRM BASE)
CHECK 3/4" TO 1 1/2"
VALVE WASHED STONE
CLEAN SAND 2" LAYER OF
HORIZ
TEXTURE
COLOR
MOTT.
1/8" TO 1/2"
0-5
Ap
LOAMY SAND
10YR3/3
10.00 MAX WASHED STONE
VENT
2-22
8
LOAMY SAND
9.88 MIN.
WEIGHT OF WATER DISPLACED
ROOTS
22-70
C
MEDIUM SAND
1 CU. FT. OF
OBSERVED WATER TABLE (2/14/02) ELEV. =
0.42
rl
NUMBER OF BEDROOMS
3-
CONCRETE
ANCHOR
TA
DRIVE
ELEV. _ _ 9_00 MIN.
TITLE 5 AND THE TOWN OF YS@M.QIL4t__ RULES AND
8.93 a
BOTTOM OF TEST HOLE ELEV. = _
LEGEND:
GARBAGE DISPOSAL UNIT
_
NO
e e p
INSIDE
FACE IS TO BE
ELEV. AT INVERT INLET
5'90
10•0
ASPHALT COATED AND
TOTAL ESTIMATED FLOW
P
ELEV.
_
_ _7.60 HAVE
6 ML. POLY ATTACHED]
ELEV. AT ALARM ON
3_90 _
WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN
EXIST NG SPOT ELEVATION 00x0
(110 GAL/BR./DAY X 3 BR.)
ELEV.
SEWAGE DISPOSAL SYSTEM PROFILE ELEV. AT PUMP ON
3'55 _
REQUIRED FLOW PER CYCLE .25 X4 = --0M5 GAL./CYCLE
EXISTING CONTOUR----00----
FINAL ELEVATION 0
REQUIRED SEPTIC TANK CAPACITY
880_ GAL.
c'
STEEL STRENGTH
.
ELEV. AT PUMP OFF
4 HIGH CAPACITY INFILTRATORS
VOLUME PER CYCLE 635 GAL/CYCLE /7.48 GAL./CU. FT. 11_03_ CU.
Fy=60,000 PSI
CONCRETE STRENGTH
-IM GAL.
WITH STONE IN AN z 4.00
I
3,000 PSI
BOTTOM 0- INSIDE PUMP CHAMBER
11" X 34" X 10• TRENCH FORMATION
WELL MIW 29
FINAL CONTOUR
SOIL TEST LOCATION
CAPACITY F SEPTIC TANK
C
1414_ GAL.
1n
ZONE
TANK
'..
11-x-
SOIL ABSORPTION
INDEX 9.7
121
_I_
SOIL ABSCRO ON SYSTEM LESS THAN 10' FROM LOT LINE.
SYSTEM (SAS)
ADJUS
C.
ELEV.
DISCHARGE _1Lg1_ CU. FT. / 36.11 CU.FT./FT. _ __0.3�
1/2
ADJUST
< B_ IN.
5X10X(5.33- 1_00
= 9
1,,81
SOIL TEST
DATE OF SOIL TEST FM14.20�-
SOIL TEST DONE BY-WQJ-ER ENGINEERING
WITNESSED BY A YQN HONE
OBSERVATION HOLE 1 ELEV.= 6_25 _
PERCOLATION RATE _< 2 MIN./INCH AT 36 INCHES
DEPTH
HORIZ
TEXTURE
COLOR
MOTT.
OTHER
0-5
Ap
LOAMY SAND
10YR3/3
NO
ROOTS
2-22
8
LOAMY SAND
10YR5/8
WEIGHT OF WATER DISPLACED
ROOTS
22-70
C
MEDIUM SAND
10YR6/8
OBSERVED WATER TABLE (2/14/02) ELEV. =
0.42
'- t� SEPTI C
2 25
5 FEET
5 F
6 FEET
19 IN HES
24 INCHES
2000 GALLON
PUMP (OR MEQ 4 OR s
(OR EQUAL)
7 2 USGS PROBABLE WATER TABLE ELEV. 3.60__
/
TABLE ELEV. = 4.90
WALL SCHEMATIC
WATER ENCOUNTERED AT 4 - ELEV. _
7 FEET
29 INCHES
SEPTIC TANK
CHAMBER CONCRETE
1000 GALLON PUMP CHAMBER (H-20)
USGS PROBABLE WATER
i25=_
(SEE CONSTRUCTION PLANS)
DESIGN CALCULATION
WEIGHT OF WATER DISPLACED
8 FEET
34 INCHES
-
8"
OBSERVED WATER TABLE (2/14/02) ELEV. =
0.42
'- t� SEPTI C
NUMBER OF BEDROOMS
3-
y
TA
DRIVE
12" CONCRETE
TITLE 5 AND THE TOWN OF YS@M.QIL4t__ RULES AND
5X10X1X735 6,750
BOTTOM OF TEST HOLE ELEV. = _
LEGEND:
GARBAGE DISPOSAL UNIT
_
NO
WEIGHT OF 8" CONCRETE
2.
ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO
ELEV. AT INVERT INLET
5'90
PUMP CHAMBER CALCULATIONS:
o y
TOTAL ESTIMATED FLOW
P
3.
ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF
D
ELEV. AT ALARM ON
3_90 _
WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN
EXIST NG SPOT ELEVATION 00x0
(110 GAL/BR./DAY X 3 BR.)
330 GAL./DAY
10 FT. OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE
SEWAGE DISPOSAL SYSTEM PROFILE ELEV. AT PUMP ON
3'55 _
REQUIRED FLOW PER CYCLE .25 X4 = --0M5 GAL./CYCLE
EXISTING CONTOUR----00----
FINAL ELEVATION 0
REQUIRED SEPTIC TANK CAPACITY
880_ GAL.
c'
ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL
.
ELEV. AT PUMP OFF
__3.23 _
VOLUME PER CYCLE 635 GAL/CYCLE /7.48 GAL./CU. FT. 11_03_ CU.
FT./CYCLE SPOT .
STANK
ACTUAL SIZE OF TC
-IM GAL.
NO DETERMINATION HAS BEEN MADE TO COMPLIANCE WITH
19.
NOT TO SCALE
BOTTOM 0- INSIDE PUMP CHAMBER
1.9-0_
_
VOLUME OF WATER IN PIPE 3.14 X 0.00694 X 22__ FT. 0_4_8_ CU. FT,
FINAL CONTOUR
SOIL TEST LOCATION
CAPACITY F SEPTIC TANK
C
1414_ GAL.
CAPACITY
OF SEPTIC
TANK
BOTTOM 0= OUTSIDE PUMP CHAMBER
11-x-
TOTAL MINIMUM VOLUME PER CYCLE 11.51 CU. FT.
FT. (1000 G.S.T.)
UTILITY POLE -o--
SOIL CLASSIFICATION
_I_
SOIL ABSCRO ON SYSTEM LESS THAN 10' FROM LOT LINE.
PRIOR TO COMMENCING WORK ON SITE.
C.
SOIL ABSORPTION SYSTEM LESS THAN 5' ABOVE WATER TABLE.
DISCHARGE _1Lg1_ CU. FT. / 36.11 CU.FT./FT. _ __0.3�
W
DESIGN PERCOLATION RATE
< B_ IN.
5X10X(5.33- 1_00
= 9
1,,81
- GALLONS
SEPTIC TANK AND PUMD CHAMBER LESS THAN 1C' FROM BUILDING.
STORAGE CAPACITY (-_330-_ GAL./DAY /7.48 GAL./CU.FT./36.11 CU.FT./FT. _
_�_ _ FT. TOWN WATER -W
EFFLUENT LOADING RATE
AL/./DAY/S.F.
.4.Z4_ GGAL
IMMEDIATELY.
_)X7.48
NO RESERVE AREA.
8.
PARCEL IS IN FLOOD ZONE 2111 SEL 11,0)
_1,22_ REQUIRED .00 2PROVIDED
CATCH BASIN ®Y
V_7
LEACHING AREA
.i4$•0 SQ. FT,
M1
GAS UNE G
1 00
82
CESSPOOLO C.P.
PUMP
LEACHING CAPACITY (AREA X RATE) 332.26 GAL./DAY
BUOYANCY CALCULATIONS: (FULL INUNDATION) CLEANOUT 0.
449.00 X 0.74
1 _ CHAMBER
1000 GALLON PUMP CHAMBER (H-20)
RESERVE LEACHING CAPACITY NONE GAL./DAY
WE:GHT OF WATER DISPLACED
WEIGHT OF WATER DISPLACED
48 p1.
-
11.00 _
DATE MAR. 29, 2002
'- t� SEPTI C
5.6 5.0'
ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P.
y
TA
DRIVE
Job No. 5344-00
TITLE 5 AND THE TOWN OF YS@M.QIL4t__ RULES AND
5X10X1X735 6,750
LBS. 8.170.42X0.83X62.5 1,873 LBS.
SHED
EXCESS WEIGHT TO OFFSET FLOTATION
WEIGHT OF 8" CONCRETE
2.
ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO
=
D. 0
o
a.
o y
25060 + 6750 - 30982
P
3.
ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF
D
8f
C)
WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN
SO
10 FT. OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE
TE r
C
N Z DEC
VENT
188.00,
c'
ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL
.
THE HAYBALE WORKUMITIS TO BE PLACED BEFORE ANY OTHER
BE MORTARED IN PLACE.
WORK COMMENCES ON SITE.
5.
NO DETERMINATION HAS BEEN MADE TO COMPLIANCE WITH
19.
THE CONTRACTOR IS TO SUPPLY AND PLACE ANY SHORING WHERE
REGULATIONS.
DEEDED OR ZONING RE OWNER /APPLICANT IS TO
NEEDED TO PROTECT BUILDING AND ABUTTING PROPERTY.
OBTAIN SUCH DETERMINAATIONTIONFROM APPROPRIATE AUTHORITY.
20.
VARIANCES TO TITLE 5 AND YARMOUTH REGULATIONS:
6
UTILITIES ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR
A.
4
.
"DIG -SAFE" AT 1-888-344-7233 AT LEAST 72 HOURS
IS TO CALL "DIG -SAFE"
B.
SOIL ABSCRO ON SYSTEM LESS THAN 10' FROM LOT LINE.
PRIOR TO COMMENCING WORK ON SITE.
C.
SOIL ABSORPTION SYSTEM LESS THAN 5' ABOVE WATER TABLE.
7.
CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS
D.
a
L07'27 Q) 14. ALL UNSUITABLE MATERIAL SHALL BE REMOVED FROM UNDER AND
AREA -9,000f SFmz FOR A MINIMUM OF 5' AROUND SOIL ABSORPTION SYSTEM AND BE
m�
REPLACED WITH MATERIAL AS SPECIFIED IN 310 CMR 15.255:(3).
- VA 15. SEPTIC TANK AND PUMP CHAMBER ARE TO BE WATERPROOFED AT
THE MANUFACTURER.
16. EXISTING CESSPOOLS ARE TO BE PUMPED AND REMOVED.
..
vru" ' n / 77. ALL DISTURBED AREAS ARE TO BE REVEGETATED.
APPROVED: BOARD OF HEALTH
PUMP SWITCHES DETAIL
ALARM ON 3,90
18• 1.
PUMP ON 3.55 T
13 13/18• 1.15"
� PUM- OfF3.23
110• „ . 0.83
DATE
AGENT
GAS UNE G
(11X34)+(45X2X1O/72)
CESSPOOLO C.P.
LEACHING CAPACITY (AREA X RATE) 332.26 GAL./DAY
BUOYANCY CALCULATIONS: (FULL INUNDATION) CLEANOUT 0.
449.00 X 0.74
2000 GALLON SEPTIC TANK (H-20)
1000 GALLON PUMP CHAMBER (H-20)
RESERVE LEACHING CAPACITY NONE GAL./DAY
WE:GHT OF WATER DISPLACED
WEIGHT OF WATER DISPLACED
NOTES:
6X11X7.33X64 30,962
LBS. 9X5.25XSX64 18,144 UBS
DATE MAR. 29, 2002
WEIGHT OF TANK PER MANUFACTURER 25,080 LBS. WEIGHT OF TANK PER MANUFACTURER 14,500 LBS.
1.
ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P.
WEIGHT OF 12" CONCRETE
WEIGHT OF WATER IN SUMP
Job No. 5344-00
TITLE 5 AND THE TOWN OF YS@M.QIL4t__ RULES AND
5X10X1X735 6,750
LBS. 8.170.42X0.83X62.5 1,873 LBS.
REGULATIONS FOR THE SUBSURFACE DISPOSAL OF SEWAGE.
EXCESS WEIGHT TO OFFSET FLOTATION
WEIGHT OF 8" CONCRETE
2.
ALL COVERS TO SANITARY UNITS SHALL BE BROUGHT TO
8.17X4.42XO.5Xi35 2,437 LBS
WITHIN 6" OF FINISHED GRADE.
25060 + 6750 - 30982
868 LBS.
EXCESS WEIGHT TO OFFSET FLOTATION
3.
ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF
14500+1873+2437-18144 666 LBS.
WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN
10 FT. OF DRIVES OR PARKING AREAS. H-20 LOADING SHALL BE
USED UNDER OR WITHIN 10 FT. OF DRIVES OR PARKING AREAS.
4.
ANY MASONARY UNITS USED TO BRING COVERS TO GRADE SHALL
18,
THE HAYBALE WORKUMITIS TO BE PLACED BEFORE ANY OTHER
BE MORTARED IN PLACE.
WORK COMMENCES ON SITE.
5.
NO DETERMINATION HAS BEEN MADE TO COMPLIANCE WITH
19.
THE CONTRACTOR IS TO SUPPLY AND PLACE ANY SHORING WHERE
REGULATIONS.
DEEDED OR ZONING RE OWNER /APPLICANT IS TO
NEEDED TO PROTECT BUILDING AND ABUTTING PROPERTY.
OBTAIN SUCH DETERMINAATIONTIONFROM APPROPRIATE AUTHORITY.
20.
VARIANCES TO TITLE 5 AND YARMOUTH REGULATIONS:
6
UTILITIES ARE APPROXIMATE ONLY, EXCAVATION CONTRACTOR
A.
SOIL ABSORDTICN SYSTEM LESS THAN 50' FROM WETLAND.(100' TOWN)
.
"DIG -SAFE" AT 1-888-344-7233 AT LEAST 72 HOURS
IS TO CALL "DIG -SAFE"
B.
SOIL ABSCRO ON SYSTEM LESS THAN 10' FROM LOT LINE.
PRIOR TO COMMENCING WORK ON SITE.
C.
SOIL ABSORPTION SYSTEM LESS THAN 5' ABOVE WATER TABLE.
7.
CONTRACTOR IS TO VERIFY GRADES AND ELEVATIONS AS WELL AS
D.
USE Or ONLY HALF THE WATER TABLE ADJUSTMENT.
SITE CONDITIONS PRIOR TO COMMENCING WORK ON SITE. ANY VARIATION
E.
SEPTIC TANK AND PUMD CHAMBER LESS THAN 1C' FROM BUILDING.
IS TO BE BROUGHT TO THE ATTENTION OF THE DESIGN ENGINEER
F.
SEPTIC TANK AND PUMP CHAMBER LESS THAN 10' FROM LOT LINE.
IMMEDIATELY.
G.
NO RESERVE AREA.
8.
PARCEL IS IN FLOOD ZONE 2111 SEL 11,0)
9.
LOT IS SHOWN ON ASSESSORS MAP 34 AS PARCEL X19_,-,
Z
10.
PUMP AND ALARM ARE TO BE ON SEPERATE CIRCUITS.
11.
ALARM IS TO BE BOTH AUDIO AND VISUAL.
J
12.
A ZABEL A1B00 FILTER IS TO BE INSTALLED.
-73
13.
AN ELECTRIC PERMIT IS REQUIRED TO WIRE PUMP AND ALARM.
L07'27 Q) 14. ALL UNSUITABLE MATERIAL SHALL BE REMOVED FROM UNDER AND
AREA -9,000f SFmz FOR A MINIMUM OF 5' AROUND SOIL ABSORPTION SYSTEM AND BE
m�
REPLACED WITH MATERIAL AS SPECIFIED IN 310 CMR 15.255:(3).
- VA 15. SEPTIC TANK AND PUMP CHAMBER ARE TO BE WATERPROOFED AT
THE MANUFACTURER.
16. EXISTING CESSPOOLS ARE TO BE PUMPED AND REMOVED.
..
vru" ' n / 77. ALL DISTURBED AREAS ARE TO BE REVEGETATED.
APPROVED: BOARD OF HEALTH
PUMP SWITCHES DETAIL
ALARM ON 3,90
18• 1.
PUMP ON 3.55 T
13 13/18• 1.15"
� PUM- OfF3.23
110• „ . 0.83
DATE
AGENT
C,
5J44-00.4JWCJ
ROUSE 2a KILLOW
LOCUS
o
PROPOSED SEPTIC DESIGN
FOR
ED FOR
LOC
LOT 27, 70 BREEZY POINT ROAD
SOUTH YARMOUTH MASS
SWEETSER ENGINEERING
235 GREAT WESTERN ROAD
508- P. 0. BOX 713
398-3922 SOUTH DENNIS, MASS. 02660
DATE MAR. 29, 2002
SCALE 1 " = 20' 7
Job No. 5344-00
REVISED
SHEET 1 OF 1
LOCATION MAP---7REvseO
C,
5J44-00.4JWCJ