Loading...
HomeMy WebLinkAbout83-1606 - Septic Design00211.5 9- MINIMUM, ACCESS COVERS MUST BE WITHIN r3' MAXIMUM COVED 6' CF FINISH GRADE \ FIRST i'' TO MIN 2' OF PEASTONE BE LEVE 3/4- - 1 1/2' D11. VOUBLE WASHED STONE 8.9 i - 9A 11 F' 'AS 3 i 0 ' @ 5 --� BAS 1 8;55 g 8 3 � r 40 OR POLY BAFFLE VAPOR BARRIER 3 OUTLET 5 HIGH CAPACITY' INFILTRATOR D OUTLET CHALABER3 W/.3.5't STONE AROUND BOX 1500 GAL ` 10'R x 38'1 x IO'd 4.9 SEPTIC TANK 6' CPUSHED STONE OR COMPACTED BASE PROF I L E: NOT To SCALE C Fh o oN 8s CSIDN FND DN PP SPIKE IN UP 42111 , EL -e.69 AOVD j� 6. 1z 0,4 v L 0CUS MAP 40 Ila FOLY, VAPOR BARRIER SOIL REP)VAL- SEE NOPE 9. VARIANCES REQUIRED: 1500 B.U. SEPTIC TANK �YVA N (TIDAL) TITLE 5. MAK'IMUA' FEASIBLE CCMPLIANCE SECTION 15.211:10 MINIAVh( SETBACK CISTANCES l0' 1S REQUIRED BETWEEN THE SAS AND THE PROPERTY LINE. 5' IS PROVIDED, A 5' VARIANCE IS RECUESTED. TOWN OF YARMOUTF' SUBSURFACE DISPOSAL OF SEWAGE REGULATIONS REGULATION 3.7: DISTANCES AND LOCATION OF DISPOSAL FACILITIES 100' IS REOVIREL BETWEEN THE OCE OF WETLANC ANL' THE SAS, 9C' IS PROVIDED. A IC' VARIANCE IS REOUES?ED. INVERT ELEVATIONS GENERAL NO TES INVERT AT BUILDING: 9.45 INVERT IN SEPTIC TANK: 8.85 INVERT OUT SEPTIC TANK: 8.6 INVERT IN DIST. BOX: 8.55 INVERT OUT DIST. BOX: 8.38 _ INVERT IN LEACH CHAMBER: 8.33 BOTTCM OF LEACH CHAMBER: 7.5 AREA HIGH GROUND WATER 2.5 OBSERVED GROUND WATER: 2.0 BOTTOM OF TEST HOLE •l: 1.0 N TOTAL LOT AREA - 9863± S.F. UFLA.ND AREA - 8796* S.F PROPOSED SUILDIN3 FOOTPRINT AI'EA . 1551+ S.F. - 17. 0x OF UPLAND. Ez��ueG 0 .'0 20 41 DESIGN CRITERIA: GENERAL NO TES DESIGN FLOW: 3 BEDPOOMS AT 1/0 G.P.D. PER I. THIS PLAN 1.9 FOR THE DESIGN AND CONSTRUCTION BEDROOM EOUALS 330 G.P.D. OF THE SEWAGE DISPOSAL SYSTEM ONLY. NO GAPBAGE GRINDER 2. VERTICAL DATUM IS NGVD. FOR BENCH MARKS SET. SEE S I TE PLAN. SEPTIC TANK REOUIPED: 330 G.P.D. X 2002 - 660 GAL. J. ALL CONSTRUCTION METHODS AND MATERIALS AND . SEPTIC TANK PPOVIDED: 1500 GAL. MIN. MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO UASS. D.E.P. TITLE 5 AND LOCAL SOIL ABSOPPTION SYSTEM REQUIRED: BOARD OF HEALTH REGULATIONS. DESIGN PEPC ,RATE ( 5 MIN/INCH SOIL TEXTURAL CLASS - 1 4, ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER EFFLUENT LOADING PATE - 0.74 GPD/SF AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER 330 GPD / 0.74 GPD/SF - 446 S.F. PEOUIRED THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. PPOVIDED: 5 HIGH CAPACITY INFILTRATOR CHAMBERS W/3.5'= STONE AROUND. A-460 S.F. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 OR 460 S.F. x 0.74 - 340 GPD APPROVED EOUAL SOIL TEST P ' T DA TA �' 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE AND WATERTIGHT. D-BCX SHALL IM1DICATES I ND ICA TES(�q BE WATER TESTED TO CHECK FOR LEVEL WHEN THERE ' _y_ PERCOLATION -_ OBSERVED IS MORE THAN ON.;' OUTLET. t8 TEST GROUNDWATER 7. BEFORE CONSTRUCTION CALL 'DIG -SAFE'. TP of 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT._ HORIZON TEXTURE COLOR FOR LOCATION OF UNDERGROUND UTILITIES. 0. 8.0 A LOAMYIOYR 8. EXISTING CESSPOOL TO BE PUMPED DRY. REMOVED SAND 4,12 AND BACKFILLED WITH CLEAN SAND. 8' _......................... 7.3 LOAMY 7.5YR B SAND 4/6 `J• ALL UNSUITABLE MATERIAL (A d B HORIZONS) 24' - -- - 6.0 ENCOUNTERED BELOW THE INVERT OF THE LEACHING C / MEDIUM IOYR FACILITY TO BE REMOVED FOR A DISTANCE OF 5' SAND 6/6 AROUND AND REPLACED WITH SAND IN ACCORDANCE WITH TITLE 5.. 10. NO DETERMINATION HAS BEEN MADE AS TO 50 COM'LIANCE WITH DEED RESTRICTIONS OR ZONING REGULATIONS, IT SHALL REMAIN THE CLIENTS RESPONSIBILITY TO OBTAIN ALL PERA+IT.S. SPECIAL 72_ 2.0 PER41TS, VARIAM:ES ETC. FOR THIS PROJECT. B4' 1.0 it. IT SHALL REMAIN THE CLIEN'T'S RESPONSIBILITY TO HAVE THE PROPOSED BUILDING FOUNDATION DATE: JUNE 26. 2002 DESIGNED TO ACCOUNT FOR THE EXISTING GRADE TEST BY: STEPHEN HAAS AND SOIL CONDITIONS AT THE LOCATION OF THE WITNESSED BY: AMY VOMR)NE PROPOSED BUILDING. PEPC RATE: ( 2 MINIINC4 '2. THE WORK L1MIT SHALL BE ESTABLISHED WITH A DOUBLE STAKED HAYBALE LINE PRIOR TO CONSTRUCTION. '3. THIS LOT FALLS WITHIN FLOOD ZONE A13(EL 9) AND FLOOD ZONE B. �5EF' T / S Y'S TEA// DE_S 7? LAKE- ROAD . MAP 49. PARCEL 234 PVA 7- T YA R lvf 0 4,/ i''f--/ . "A , PRL�PAR�G FOR S_'ALE: 20 JANUARY -9. 2004 REVISED: JANUARY 26. 2004 EAGLE SURVEY I NG I NC _ 923 Route 6A Yarmouthport MA. 02675 ( 508) 362-811-2 Gc� /i l'I