INSPECTION
PORTS FOP
ONS:
MERCURY FC OAT
INVERT AT BUILDING:
9" MINIMUM COVER
PERCOLATION = OBSERVED
FAST UNIT
TO BE BROUGHT
ACCESS COVERS MUST BE WITHIN
FIRST 2- TO
h
m
_
TO FINISH
GRADE
6' OF FINISH GRADE
BE LEVEL
COLOR 5 HORIZON TEXTURE
4" PERF PIPE
INVERT OUT PUMP CHAMBER:
BLOWER TO
BE PLACED
NO GARBAGE GRINDER
TEE
8.32
4"VENT
MIN. 1' OF
WITHIN 60
OF FAST UNIT
VENT
BAY
INVERT IN LEACH FIELD:
LOCUS
PEASTON'£
440 G.P.D. X 200% - 880 GAL.
40'
�- 1.9
9.35 MIN
2X 18' MIN
8.0
PEA T
18" MIN
7.5
8.
SOIL ABSORPTION SYSTEM REQUIRED:
0
2.5
C I COARSE
8. 32
OBSERVED GROUND WATER:
pamopopeo o
-o o o _
REINFORCED CONCRETE
4' DIAM PIPE
_
J FAST
2' SCH 40 PVC
o 8. 15
4' SOLID PIPE
RETAINING WALL
4.25
3.8 3.5
8. !
- I
8. Q
4.05
AREA - 600 S.F x 0.74 -444 G.P.D.
3.75
9 OUTLET
DOUBLE SHED STODIANE
DOUBLE WASHED STONE
e 7.5
M 8 MI L POLY
S.J+
SAND
D BOX
VAPOR BARRIER
-17.1
DATE: OCTOBER 8. 2002
TEST BY: STEPHEN HAAS
J500 GAL
H-20 PUMP CHAMBER
WITNESSED BY: AMY VONHON'E
OBSERVED
PEPC RATE: ( 2 MIN/INCH ASSUMED IN CI
H-20 SEPTIC TANK
TP #I
_V
GROUNDWATER. EL -1.9
0' HORIZON TEXTURE COLOR 5 2
WATERTIGHT AND
\
A LOAMY
FAST READY
FACTORY WATERPROOFED
20 'x 30' LEACH FIELD
8 4,5
WATERTIGHT AND
FILL..
FACTORY WATERPROOFED 6" CRUSHED STONE OR
=C I SANDY IOYR
COMPACTED BASE
LOAM 3/l
48' i.2
PROFILE: Nor TO SCALE
C2 LOAMY
GENERAL NOTES:
1. THIS PLAN 1S FOR THE DESIGN AND CONSTRUCTION
OF THE SEWAGE DISPOSAL SYSTEM AND PERMITTING
PURPOSES ONLY.
2. VERTICAL DATUM /S NGVD. FOR BENCH MARKS
SET, SEE SITE PLAN.
J. LIMIT OF WETLAND VEGETATION WAS DELINEATED
BY HAMLYN CONSULTING. LIMIT OF COASTAL BANK
WAS DELINEATED BY ENSP.
4. ALL CONSTRUCTION METHODS AND MATERIALS AND
MAINTENANCE OF THE SEPTIC SYSTEM SHALL
CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL
BOARD OF HEALTH REGULATIONS.
5. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER
AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER
THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH-
STANDING H-20 WHEEL LOADS.
6. ALL SEWER PIPE SHALL BE SCHEDULE 40 OR
APPROVED EQUAL.
7. SEPTIC TANK. PUMP CHAMBER AND D -BOX SHALL BE
REINFORCED PRECAST CONCRETE, WATERTIGHT AND
WATERPROOF. D -BOX SHALL BE WATER TESTED TO
CHECK FOR LEVEL WHEN THERE IS MORE THAN ONE
OUTLET.
8. BEFORE CONSTRUCTION CALL 'DIG -SAFE-.
1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT.
FOR LOCATION OF UNDERGROUND UTILITIES.
9. SEPTIC SYSTEM INSTALLER SHALL NOTIFY THE
DESIGN ENGINEER TWO DAYS PRIOR TO CONSTRUCTION
OF THE SYSTEM TO ALLOW FOR SCHEDULING OF THE
CONSTRUCTION INSPECTIONS. THE FOLLOWING INSPEC-
TIONS SHALL BE DONE AT A MINIMUM:
I. DURING THE REQUIRED EXCAVATION.
2. FOOTING FORMS AND REBAR PRIOR TO POURING
3. WALL FORMS AND REBAR PRIOR TO POURING.
4. FINAL INSPECTION OF SEPTIC TANK. PUMP AND
LEACHING FIELD PRIOR TO BACKFILLING.
10. ALL UNSUITABLE MATERIAL !FILL AND PEAT)
ENCOUNTERED BELOW THE INVERT OF THE LEACHING
FACILITY TO BE REMOVED FOR A DISTANCE OF 5'
AROUND TO A DEPTH OF 12'-16" AND REPLACED
WITH SAND IN ACCORDANCE WITH TITLE 5.
ll. ANY RETAINING WALL SHOWN ON THIS PLAN IS FOR
LOCATION ONLY AND SHALL CONSTRUCTED IN ACCOR-
DANCE WITH THE DESIGN PROVIDED ON A SEPARATE
SHEET.
12. IT SHALL REMAIN THE CLIENT '$ RESPONSIBILITY
TO HAVE THE PROPOSED BUILDING FOUNDATION
DESIGNED TO ACCOUNT FOR THE EXISTING GRADE
AND SOIL CONDITIONS AT THE LOCATION OF THE
PROPOSED BUILDING.
13. NO DETERMINATION HAS BEEN MADE AS TO
COMPLIANCE WITH DEED RESTRICTIONS OR ZONING
REGULATIONS. IT SHALL REMAIN THE CLIENTS
RESPONSIBILITY TO OBTAIN ALL PERMITS. SPECIAL
PERMITS. VARIANCES ETC. FOR THIS PROJECT.
14. INSTALLATION OF FAST UNIT TO BE CERTIFIED BY
FAST REPRESENTATIVE. A YEARLY INSPECTION AND
MAINTENANCE CONTRACT SF -'_'L EE MA,r: TAr^,ED WITH
THE FAST REPRESENTATIVE.
BOUYANCY CALCULATIONS:
SEPTIC TANK DISPLACEMENT - (2.5-1-0.7) x 11 x 6.17 - 217 C.F.
217 C.F. x 62.4 07C.F. - 13540#. H-20 TANK - 21230+ OK
PUMP CHAMBER DISPLACEMENT - (2.5-(-1.0) x 9 x 5.25 - 165 C.F.
165 C.F. x 62.4 #7C.F. - 10296«. H-20 TANK - 14500# OK
VARIANCES REQUIRED:
TITLE 5, MAXIMUM FEASIBLE COMPLIANCE
SECTION 15.211:(1) MINIMUM SETBACK DISTANCES
10' IS REQUIRED BETWEEN THE SEPTIC TANK AND THE PROPERTY LINE. 8' IS PROVIDED.
A 2' VARIANCE /S REQUESTED. 10' IS REQUIRED BETWEEN THE PUMP CHAMBER AND
THE PROPERTY LINE. 2' IS PROVIDED. AN B' VARIANCE IS REQUESTED. 10' IS
REQUIRED BETWEEN THE PUMP CHAMBER AND THE CELLAR WALL. 5' IS PROVIDED. A 5"
VARIANCE IS REQUESTED. 10' 1S REQUIRED BETWEEN THE SAS AND THE PROPERTY LINE.
4' IS PROVIDED, A 6' VARIANCE IS REQUESTED.
TOWN OF YARMOUTH SUBSURFACE DISPOSAL OF SEWAGE REGULATIONS
REGULATION 3.7: DISTANCES 6 LOCATION OF DISPOSAL FACILITIES
50'IS REQUIRED BETWEEN THE SEPTIC TANK AND THE WETLAND. 45' IS PROVIDED.
Cd
A 5' VARIANCE /S REQUESTED. 100' IS REQUIRED BETWEEN THE SAS AND THE /
WETLAND. 70' IS PROVIDED TO THE TOP OF BANK. A 30' VARIANCE IS REQUESTED.
CB#2
�F
P
oA 2
-
/ `aG
JC CBr3ri
/ 5
CBrI
CB -4
GEC CB/DISK FND
I
BVW*P
<,v
o ,
~v'r
<4 r,
0
CESSPOOL
VELE TA'ED WE
BYW.3 r
7br, BVW#7 F,V
o \` \orfOPV-= ./ • �\5S\�
1 \ 8VW. 4
----- ---- BUMS
Ap
C£SSP014!' < I V
y - 150e 'CA
a SERTIC TANK - Q�
p`! WiFA ST JNIT
L j0P c PUMP `y
lNV•1.5 .SPS. OF = \ .o CHAMBEP i cc
+ TP11
�� T
<
..•I,�Cp# I - or
CDPJ - 6 O'_
<
20'r JO' L£ CH lft Too QO�i
y4 v <
CD#I SOIL RfM AL
<
00
'( ' �`•r' RETAINING LL A
UPLAND -19.240+ S.F. 4`< CD#5
[INV -1.5 \._ WETLAND -760* S.F.
\
TOTAL -20 . 000* S.F.
CD#6 CD09
Y� 00
!!0
O#8 ,
y� 00 It OF COASTAL DUN
p Y
COW LAW co
it 4,1.
� y?� �4�- Co. 1\0}_
9f
9C
m�
v<y
\/ �F
H
G
V Fy
\ 2
RETAINING WALT
WITOP - EL 9!
METER P I T yi
oa\
o \ GP of
05
T�<o0 ePo
0
S r4y �4
'W\
PUMP SYSTEM NOTES
PUMP TO BE MYERS RESIDENTIAL SEWAGE PUMP MODEL SRM4
OR EQUAL.
THE PUMP SHALL START AND STOP AT THE ELEVATIONS SHOWN.
THE PUMP SHALL BE INSTALLED IN STRICT CONFORMANCE WITH
THE MANUFACTURER'S SPECIFICATIONS AND TITLE V REGULATIONS.
PUMP DISCHARGE SHALL BE 2 INCHES. PUMP SHOULD BE ABLE TO
BE DISCONNECTED AND LIFTED OUT OF THE PUMP CHAMBER WITHOUT
HAVING TO ENTER THE PUMP CHAMBER.
THE ALARM SHALL START AT THE ELEVATION SHOWN AND BE
POWERED BY A CIRCUIT SEPARATE FROM THE PUMP POWER.
AN ELECTRICAL PERMIT MUST BE OBT41NED FOR THIS INSTALLATION
4' PVC INLET
I -2T D"
�l
COUPLING
ONS:
MERCURY FC OAT
INVERT AT BUILDING:
SWITCHES WEEP
PERCOLATION = OBSERVED
HOLE
INVERT IN SEPTIC TANK.
4
TEST _ GROUNDWATER
h
m
_
TB #2
PUMP OFF PWP
6'S
INVERT IN PUMP CHAMBER:
6.75
COLOR 5 HORIZON TEXTURE
COLOR
INVERT OUT PUMP CHAMBER:
6.5
2 0" -
NO GARBAGE GRINDER
INVERT IN DIST. BOX:
8.32
-,
LOCUS`,
INVERT OUT DIST. BOX:
-.
LEWIS
BAY
INVERT IN LEACH FIELD:
LOCUS
MAP
BOUYANCY CALCULATIONS:
SEPTIC TANK DISPLACEMENT - (2.5-1-0.7) x 11 x 6.17 - 217 C.F.
217 C.F. x 62.4 07C.F. - 13540#. H-20 TANK - 21230+ OK
PUMP CHAMBER DISPLACEMENT - (2.5-(-1.0) x 9 x 5.25 - 165 C.F.
165 C.F. x 62.4 #7C.F. - 10296«. H-20 TANK - 14500# OK
VARIANCES REQUIRED:
TITLE 5, MAXIMUM FEASIBLE COMPLIANCE
SECTION 15.211:(1) MINIMUM SETBACK DISTANCES
10' IS REQUIRED BETWEEN THE SEPTIC TANK AND THE PROPERTY LINE. 8' IS PROVIDED.
A 2' VARIANCE /S REQUESTED. 10' IS REQUIRED BETWEEN THE PUMP CHAMBER AND
THE PROPERTY LINE. 2' IS PROVIDED. AN B' VARIANCE IS REQUESTED. 10' IS
REQUIRED BETWEEN THE PUMP CHAMBER AND THE CELLAR WALL. 5' IS PROVIDED. A 5"
VARIANCE IS REQUESTED. 10' 1S REQUIRED BETWEEN THE SAS AND THE PROPERTY LINE.
4' IS PROVIDED, A 6' VARIANCE IS REQUESTED.
TOWN OF YARMOUTH SUBSURFACE DISPOSAL OF SEWAGE REGULATIONS
REGULATION 3.7: DISTANCES 6 LOCATION OF DISPOSAL FACILITIES
50'IS REQUIRED BETWEEN THE SEPTIC TANK AND THE WETLAND. 45' IS PROVIDED.
Cd
A 5' VARIANCE /S REQUESTED. 100' IS REQUIRED BETWEEN THE SAS AND THE /
WETLAND. 70' IS PROVIDED TO THE TOP OF BANK. A 30' VARIANCE IS REQUESTED.
CB#2
�F
P
oA 2
-
/ `aG
JC CBr3ri
/ 5
CBrI
CB -4
GEC CB/DISK FND
I
BVW*P
<,v
o ,
~v'r
<4 r,
0
CESSPOOL
VELE TA'ED WE
BYW.3 r
7br, BVW#7 F,V
o \` \orfOPV-= ./ • �\5S\�
1 \ 8VW. 4
----- ---- BUMS
Ap
C£SSP014!' < I V
y - 150e 'CA
a SERTIC TANK - Q�
p`! WiFA ST JNIT
L j0P c PUMP `y
lNV•1.5 .SPS. OF = \ .o CHAMBEP i cc
+ TP11
�� T
<
..•I,�Cp# I - or
CDPJ - 6 O'_
<
20'r JO' L£ CH lft Too QO�i
y4 v <
CD#I SOIL RfM AL
<
00
'( ' �`•r' RETAINING LL A
UPLAND -19.240+ S.F. 4`< CD#5
[INV -1.5 \._ WETLAND -760* S.F.
\
TOTAL -20 . 000* S.F.
CD#6 CD09
Y� 00
!!0
O#8 ,
y� 00 It OF COASTAL DUN
p Y
COW LAW co
it 4,1.
� y?� �4�- Co. 1\0}_
9f
9C
m�
v<y
\/ �F
H
G
V Fy
\ 2
RETAINING WALT
WITOP - EL 9!
METER P I T yi
oa\
o \ GP of
05
T�<o0 ePo
0
S r4y �4
'W\
PUMP SYSTEM NOTES
PUMP TO BE MYERS RESIDENTIAL SEWAGE PUMP MODEL SRM4
OR EQUAL.
THE PUMP SHALL START AND STOP AT THE ELEVATIONS SHOWN.
THE PUMP SHALL BE INSTALLED IN STRICT CONFORMANCE WITH
THE MANUFACTURER'S SPECIFICATIONS AND TITLE V REGULATIONS.
PUMP DISCHARGE SHALL BE 2 INCHES. PUMP SHOULD BE ABLE TO
BE DISCONNECTED AND LIFTED OUT OF THE PUMP CHAMBER WITHOUT
HAVING TO ENTER THE PUMP CHAMBER.
THE ALARM SHALL START AT THE ELEVATION SHOWN AND BE
POWERED BY A CIRCUIT SEPARATE FROM THE PUMP POWER.
AN ELECTRICAL PERMIT MUST BE OBT41NED FOR THIS INSTALLATION
4' PVC INLET
I -2T D"
�l
PUMP DETA IL NOT TO SCALE
USING /000 GAL. PUMP CHAMBER
WATERTIGHT AND WATERPROOF
2" PVC OUTLET
r. 48N
- .: ,�.-
.L�. -
0 ,.-.. 40
I LAVER T EL EVA
COUPLING
ONS:
MERCURY FC OAT
INVERT AT BUILDING:
SWITCHES WEEP
PERCOLATION = OBSERVED
HOLE
INVERT IN SEPTIC TANK.
ALARM ON
TEST _ GROUNDWATER
PUMP ON CHECK
VALVE
INVERT OUT SEPTIC TANK:
S.6' RAW
TB #2
PUMP OFF PWP
6'S
INVERT IN PUMP CHAMBER:
6.75
PUMP DETA IL NOT TO SCALE
USING /000 GAL. PUMP CHAMBER
WATERTIGHT AND WATERPROOF
2" PVC OUTLET
r. 48N
- .: ,�.-
.L�. -
0 ,.-.. 40
I LAVER T EL EVA
T I
ONS:
DESIGN CR i TER 1 A :
INVERT AT BUILDING:
7.25
PERCOLATION = OBSERVED
DESIGN FLOW:
INVERT IN SEPTIC TANK.
7.05
TEST _ GROUNDWATER
4 BEDROOMS AT 110 G P.O. PER
INVERT OUT SEPTIC TANK:
6.8
TB #2
BEDROOM EQUALS 440 G P.D.
INVERT IN PUMP CHAMBER:
6.75
COLOR 5 HORIZON TEXTURE
COLOR
INVERT OUT PUMP CHAMBER:
6.5
2 0" -
NO GARBAGE GRINDER
INVERT IN DIST. BOX:
8.32
FILL
INVERT OUT DIST. BOX:
8.15
40'
SEPTIC TANK REQUIRED:
INVERT IN LEACH FIELD:
8.1
440 G.P.D. X 200% - 880 GAL.
40'
�- 1.9
SEPTIC TANK PROVIDED 1500 GAL. MIN.
INVERT END LEACH FIELD:
8.0
PEA T
BOTTOM LEACH FIELD:
7.5
IBB'
SOIL ABSORPTION SYSTEM REQUIRED:
HIGH GROUND WATER:
2.5
C I COARSE
DESIGN PERC RATE ( 5 MIN/INCH
OBSERVED GROUND WATER:
1.9
SAND
SOIL TEXTURAL CLASS - I
BOTTOM OF TEST BORING #2:
-17.1
-7.1 200
EFFLUENT LOADING RATE - 0.74 GPD/SF
C I COARSE
2.5Y C2 FINE
1,
440 GPD / 0.74 GPD/SF - 595 S.F. REQUIRED
SAND
6/1 SAND
PPCVIDED: 20'x 30' LEACH FIELD. 6' DEEP
2/6"
AREA - 600 S.F x 0.74 -444 G.P.D.
SOIL TEST PI T DATA&
S / TE PL 4 L ,4 NO
7 5 TONE 4 VENUE . ",4 P 20 . 1=',4 RCEL 30
WE S T YA R"O LI T H . "A.
PRE P,4 REO FOR
OR . 1-1,4 R OL O L O V/ /VE
P O. BOX /6<5. Y,4RMOlJTf-1PORT" 1,1IA 02675
OCTOBER / 6 " 2002
REVISED: OCTOBER 28. 2002
REVISED: NOVEMBER 25. 2002
E A G L E SLJFRVEY I NG , I NC
923 Route 6A
r_ YOrmc, uthport MA. 02675
II/I,�I ( 508 ) 362-S132
/ I oNk
( 508 ) 4-32-5333
I
INDICATES/ ADlCATES
PERCOLATION = OBSERVED
TEST _ GROUNDWATER
TB *I
TB #2
0.
HORIZON TEXTURE
COLOR 5 HORIZON TEXTURE
COLOR
2 0" -
- 5.2
FILL
40'
/.9
FILL
40'
�- 1.9
PEA T
IBB'
-10.5
PEA T
C I COARSE
SAND
143--
.. - -
-7.1 200
C I COARSE
2.5Y C2 FINE
1,
SAND
6/1 SAND
2/6"
-12.8
C,3 MEDIUM
SAND
216
-12.8 264 -
-17.1
DATE: OCTOBER 8. 2002
TEST BY: STEPHEN HAAS
WITNESSED BY: AMY VONHON'E
PEPC RATE: ( 2 MIN/INCH ASSUMED IN CI
TP #I
0' HORIZON TEXTURE COLOR 5 2
\
A LOAMY
SAND
8 4,5
FILL..
QD• 1.9
=C I SANDY IOYR
LOAM 3/l
48' i.2
C2 LOAMY
SAND
4-
64--
C3 MED -COARSE 2.5Y
C,3
SAND 571
96" -2 8
C4 PEAT
ORGANIC
156 " -7. 8
DATE: MARCH 24, 1999
TEST BY: FLAHERTY. STEFANI A BRACKEN
WITNESSED BY: AMY VONHONE
S / TE PL 4 L ,4 NO
7 5 TONE 4 VENUE . ",4 P 20 . 1=',4 RCEL 30
WE S T YA R"O LI T H . "A.
PRE P,4 REO FOR
OR . 1-1,4 R OL O L O V/ /VE
P O. BOX /6<5. Y,4RMOlJTf-1PORT" 1,1IA 02675
OCTOBER / 6 " 2002
REVISED: OCTOBER 28. 2002
REVISED: NOVEMBER 25. 2002
E A G L E SLJFRVEY I NG , I NC
923 Route 6A
r_ YOrmc, uthport MA. 02675
II/I,�I ( 508 ) 362-S132
/ I oNk
( 508 ) 4-32-5333
I
INSPECTION PORTS FOP 9' MINIMUM COVER
FAST UNIT TO BE EROUGHTi ACCESS COVERS MUST BE WITHIN FIRST 2' TO
TO FINISH GRADE 6' OF FINISH GRADE BE LEVEL 4' PERF PIPE
BLOIYEP TO BE PLACED TEE 'VENT
WITHIN 60' OF FAST UNIT VENT 9.35 MIN 2X
8' MIN
f IB' MIN
6
6.32 ° I _
4' O/AM PIPE FAST 2' SCH 40 PVC o 8. 15 4• SOLID PIPE
-- 8. 1 3/4' - I 1/2' DIA8.0
4.25_ 3. 8 3' 5 DOUBLE WASHED STONE J, 5
'
4.05 .75
9 OUTLET r B MIL POLY
3
D -BOX � VAPOR BARRIER
%009 OBSERVED
1500 GAL H-20 PUMP CHAMBER GROUNDWATER. EL -l.9
H-20 SEPTIC TANK WATERTIGHT AND
FAST READY FACTORY WATERPROOFED 20'x 30' LEACH FIELD
WATERTIGHT AND
FACTORY WATERPROOFED 6- CRUSHED STONE OR
COMPACTED BASE
PROFILE:NOT TO SCALE
GENERAL NOTES: BOUYANCY CALCULATIONS:
1. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION SEPTIC TANK DISPLACEMENT - (2.5-(-0.7) x II x 6.17 - 217 C.F.
OF THE SEWAGE DISPOSAL SYSTEM AND PERMITTING 217 C.F. x 62.4 */C.F. - I3540*. H-20 TANK - 21230+ OK
PURPOSES ONLY.
PUMP CHAMBER DISPLACEMENT - (2.5-(-1.0) x 9 x 5.25 - 165 C.F.
2. VERTICAL DATUM IS NGVD. FOR BENCH MARKS 165 C.F. x 62.4 */C.F. - 10296*, H-20 TANK • 14500* OK
SET, SEE S1 T£ PLAN.
3. LIMIT OF WETLAND VEGETATION WAS DELINEATED
BY HAMLYN CONSULTING. LIMIT OF COASTAL BANK
WAS DELINEATED BY ENSR.
4. ALL CONSTRUCTION METHODS AND MATERIALS AND
MAINTENANCE OF THE SEPTIC SYSTEM SHALL
CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL
BOARD OF HEALTH REGULATIONS.
5. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER
AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER
THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH-
STANDING H-20 WHEEL LOADS.
6. ALL SEWER PIPE SHALL BE SCHEDULE 40 OR
APPROVED EQUAL.
7. SEPTIC TANK. PUMP CHAMBER AND D -BOX SHALL BE
REINFORCED PRECAST CONCRETE. WATERTIGHT AND
WATERPROOF, D -BOX SHALL BE WATER TESTED TO
CHECK FOR LEVEL WHEN THERE IS MORE THAN ONE
OUTLET.
8. BEFORE CONSTRUCTION CALL -DIG-SAFE'.
1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT.
FOR LOCATION OF UNDERGROUND UTILITIES,
9. SEPTIC SYSTEM INSTALLER SHALL NOTIFY THE
DESIGN ENGINEER TWO DAYS PRIOR TO CONSTRUCTION
OF THE SYSTEM TO ALLOW FOR SCHEDULING OF THE
CONSTRUCTION INSPECTIONS. THE FOLLOWING INSPEC-
TIONS SHALL BE DONE AT A MINIMUM:
I. DURING THE REQUIRED EXCAVATION.
2. FOOTING FORMS AND'REBAR PRIOR TO POURING
3. WALL FORMS AND REBAR PRIOR TO POURING.
4. FINAL INSPECTION OF SEPTIC TANK. PUMP AND
LEACHING FIELD PRIOR TO BACKFILLING.
10. ALL UNSUITABLE MATERIAL (FILL AND PEAT)
ENCOUNTERED BELOW THE INVERT OF THE LEACHING
FACILITY TO BE REMOVED FOR A DISTANCE OF 5'
AROUND TO A DEPTH OF 12'-16' AND REPLACED
WITH SAND IN ACCORDANCE W I TH TITLE 5.
11. ANY RETAINING WALL SHOWN ON THIS PLAN IS FOR
LOCATION ONLY AND SHALL CONSTRUCTED IN ACCOR-
DANCE WITH THE DESIGN PROVIDED ON A SEPARATE
SHEET.
12. IT SHALL REMAIN THE CLIENT'S RESPONSIBILITY
TO HAVE THE PROPOSED BUILDING FOUNDATION
DESIGNED TO ACCOUNT FOR THE EXISTING GRADE
AND $OIL CONDITIONS AT THE LOCATION OF THE
PROPOSED BUILDING.
13. NO DETERMINATION HAS BEEN MADE AS TO
COMPLIANCE WITH DEED RESTRICTIONS OR ZONING
REGULATIONS. IT SHALL REMAIN THE CLIENTS
RESPONSIBILITY TO OBTAIN ALL PERMITS, SPECIAL
PERMITS. VARIANCES ETC. FOR THIS PROJECT.
14. INSTALLATION OF FAST UNIT TO BE CERTIFIED BY
FAST REPRESENTATIVE. A YEARLY INSPECTION AND
MAINTENANCE CONTRACT SHALL BE MAINTAINED WITH
THE FAST PEPOESE.NTATIVE.
I
I i �
LOc;�t
LEWIS BAY
i L OCUS MAP
VARIANCES REQUIRED:
MIN, 2' Or
PEA $ TONE
REINFORCED CONCRETE
RETAINING WALL
TITLE 5. MAXIMUM FEASIBLE COMPLIANCE
SECTION 15.211:(1) MINIMUM SETBACK DISTANCES
10' IS REQUIRED BETWEEN THE SEPTIC TANK AND THE PROPERTY LINE. 8' IS PROVIDED.
A 2' VARIANCE IS REQUESTED. IO' IS REQUIRED BETWEEN THE PUMP CHAMBER AND
THE PROPERTY LINE. 2' IS PROVIDED. AN 8' VARIANCE IS REQUESTED. 10' IS
REQUIRED BETWEEN THE PUMP CHAMBER AND THE CELLAR WALL. 5' IS PROVIDED. A 5'
VARIANCE IS REQUESTED. 10' IS REQUIRED BETWEEN THE SAS AND THE PROPERTY LINE.
4' IS PROVIDED, A 6' VARIANCE IS REQUESTED.
TOWN OF YARMOUTH SUBSURFACE DISPOSAL OF SEWAGE REGULATIONS
REGULATION 3.7: DISTANCES 6 LOCATION OF DISPOSAL FACILITIES
50'IS REQUIRED BETWEEN THE SEPTIC TANK AND THE WETLAND. 45' IS PROVIDED.
I
GEC CB/DISK FND
VEGETATED N
Caa
BVW.B
VW,9
A 5' VARIANCE IS REQUESTED. 100' IS REQUIRED BETWEEN THE SAS AND THE / '!° BVNR3 I__
WETLAND. 70' IS PROVIDED TO THE TOP OF BANK. A 30' VARIANCE IS REQUESTED.8YW*7 -Z lc4tiO\ ,'
' 01 !
G
00 0? o 8VW14
1 `\ uP.e
Wts*
/.
V� 5.0.
h - & h }pC
\
/ O � CESSPOOL 4P �..f
! 50 'GAL
SEPTIC
WiFASTwvlr UNIT
pp /: .y �� :- /; � ,� ♦q!r
,r _ 111
p1 app / doe
OPS �\ \i op
+_" / Pc 'PUMP
CHAMBER
INV -l.5 5 // / - /
// ,+� hTPII ! 6 \\ �'~ •A' RETAINING WALL'
0
'B. w TOP EL 910 `\
CBRS/ /' - -0i1 METER P/C0.\AE'
CIPTA`' / •'/! -OTB ��'\ \rLp '��•'1,' .�0`' /
�'1 I CD12' - .. CD* 3 F' 1 a C. r pp5. J� 0 0`
co 2C-
�20'A 30' 1£ CH IEL
P4 SOIL REM AL
SEE NOTE
RETAININ_G LL
L O TS',, \S S. T, U,
y'ti QP
\ UPLAND -I9.240+ S.F. ` "l( ODs\{s.s
�INY•L5 \ \\ WETLAdD,760' S.F.-
\\\ TOTAL -20.)0\001 S.F.
- ----------
\ s \ CDR6 CDW9 ,,O '
CD*eLIN
,
COASTAL D
\ /` \
.\ \\ 9S1 \ \ 1
} 9! s\ \ t
\ B�
\
\
PUMP SYSTEM NOTES:
1. PUMP 70 8E MYERS RESIDENTIAL SEWAGE P:M MODEL SPW 4 PVC INLET COOPL IN6 PVC OUTLET
OR EOUAL. .ERNRY FLOAT
SWITCHES WEEP
HOLE
\ 2. THE PLAMP SHALL START AND STOP AT THE ELEVATICNS SHOWY ALAR. OW_
RMR ON YALYE
J. THE PUMP SHALL BE INSTALLED IN STRICT CONFORMAwf WITH S. S' RAW
THE MANUFACTURER'S SPECIFICATIONS AND TITLE V PFGLTATICNS. PWP OFF
PUMP DISCHARGE SHALL BE 2 INCHES. PUMP SHOULD BF ABLE TO PwP
BE DISCONNECTED AND LIFTED OUT OF THE PUMP CHAWE' WITHOUT B•a
HAVING TO ENTER THE PUMP CHAMBER..
4. THE ALARM SHALL START AT THE ELEVATION SHOWN AND BE PUMP DE TA I L :NOT TO SCALE
POWERED BY A CIRCUIT SEPARATE FROM THE PLW' PDWT_R, USING 1000 GAL. PUMP CHAMBER
5. AN ELECTRICAL PERMIT MUST BE OBTAINED FOR THIS IRSTALLATICN. WATERTIGHT AND WATERPROOF
INVERT ELEVATIONS:
DESIGN CRITERIA:
INVERT
AT BUILDING:
7.25
DESIGN FLOW:
INVERT
IN SEPTIC TANK:
7.05
4 BEDROOMS AT I10 G.P.D. PER
INVERT
OUT SEPTIC TANK:
6.8
BEDROOM EQUALS 440 G.P.D.
INVERT
IN PUMP CHAMBER:
6.75
INVERT
OUT PUMP CHAMBER:
6.5
NO GARBAGE GRINDER
INVERT
IN DIST. BOX:
8.32
SEPTIC TANK REQUIRED:
INVERT
OUT DIST. BOX:
8.15
440 G.P.D. X 200x - 880 GAL.
INVERT
IN LEACH FIELD:
8'1
SEPTIC TANK PROVIDED: 1500 GAL. MIN.
INVERT
END LEACH FIELD:
8.0
BOTTOM
LEACH FIELD:
7.5
SOIL ABSORPTION SYSTEM REOUIRED:
HIGH GROUND WATER:
2.5
DESIGN PERC RATE C 5 MIN/INCH
OBSERVED GROUND WATER:
1.9
SOIL TEXTURAL CLASS - I
BOTTOM
OF TEST BORING *2:
-17.1
EFFLUENT LOADING RATE - 0.74 GPD/SF
440 GPD / 0.74 GPD/SF - 595 S.F. REQUIRED
PROVIDED: 20'x 30' LEACH FIELD, 6• DEEP
AREA • 600 S.F. x 0.74 - 444 G.P.D.
SOIL TEST PIT DA TA
INDICATES-` INDICATES
PERCOLATION = OBSERVED
TEST GROUNDWATER
TB *1 TB *2
0- HORIZON TEXTURE COLOR 5.2 0' HORIZON TEXTURE COLOR 5.2
FILL
40' 1.9
FILL
40 1.9
PEA T
188-' .......................................... -10.5
PEA T C I COARSE
SAND
_.......................................... -11.5
148 ................................... 7. I 200 '
\48N '....... C I COARSE 2.5YC2 FINE
SAND 6/1 SAND
0 IO 20 - 40
216' ......................._................ -12.8
C.3 MEDIUM
SAND
216' F -12.8 264' 17.1
DATE: OCTOBER 8. 2002
TEST BY: STEPHEN HAAS
WITNESSED BY: AMY VONHONE
PERC RATE: ( 2 MIN/INCH ASSUMED IN Cl
TP ►1
0' HORIZON .TEXTURE COLOR 5 2
A LOAMY
SAND
8 - .... ...... .... ..... 4.5
FILL
40- ..... .. .... .. . 1.9
c/ SANDY IOYR
LOAM 3/1
48- . ..... . .. ...... 1.2
C2 LOAMY
SAND
64 -0.1
C3 MED -COARSE 2.5Y
SAND 5/1
96. -2.8
C4 PEAT
ORGANIC
156' 7.8
DATE: MARCH 24. 1999
TEST BY: FLAHERTY, STEFANI d BRACKEN
WITNESSED BY: AMY VONHONE
t L -
i r
7 S T0/VE A VENUE. MAP 20. PARCEL 30
WES T YA R/SOU TI -1, MIA
PREPARED FOR :
OR. "AROLO LEV /NEI
P. 0. BOX /68. YARMOUT"PORT. MA 02675
SCAL E / 20' OCTOBER 16. 2002
REVISED: OCTOBER 28, 2002
REVISED: NOVEMBER 25, 2002
EAGLE SURVEYING, INC
_ 923 Route 6A
Yorrrnouthport MA. 02675
( 508 ) 362-B132