HomeMy WebLinkAbout83-1621 - Site PlanTOP FNDN. = 12.5' SYSTEM PROFILE (PROP) /-'-" ACCESS COVER TO WITHIN 6" OF FIN. GRADE (NOT TO SCALE) // ACCESS COVER (WATERTIGHT) TO MINIMUM .75' OF COVER OVER PRECAST WITHIN 6" OF FIN. GRADE 2% SLOPE REQUIRED OVER SYSTEM RUN PIPE LEVEL a" PERF. PVC \ 2• PEASTONE 9.0' FOR FIRST 2' \ PROPOSED 1500 - 8.7 GALLON SEPTIC $ 49' TANK (H- 10 ) AS ` AFFLE8,4Q' MIN ( 2 % SLOPE) �_6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [2]) DEPTH OF FLOW = 4' ( 1 % SLOPE) ( % SLOPE) TEE SIZES: INLET DEPTH = 10" OUTLET DEPTH - 14" FOUNDATION- 10' - SEPTIC TANK 9' D' BOX \S. + eft #s<46�' HE2.37 -142.38 90-185 / ' 1 1 11, +12.46 I 1 01 4<53 cJf +11.32 112.56 1 1 +11.56 SH ` L ` '+112.28 .i. +11.43 DRI -'WAY �13R9312.4Y' 10.59 \ EXISTING I WELL _ +Ig1.61 EXISTING HOUSE (MATCHED) FF) ELEV 11/76' O6I Xn.54 UTILITY POLE �/ \ 2.64 72.67\ 6�2 0? rn � '� \ X12.79 PAVED DRIVEWAY +1 4\ K \ 30" OAK / 113' PROPOSED WORK LIMIT LINE OF STAKED HAYBALES AND SILT FENCE 8.5' I 15' -3/8" TO 1-1/2" WASHED STONE USE ADJ. WATER AT EL. 2.5' (TIDALLY INFLUENCED) 10' LEACHING FACILITY EXISTING I WELL - AO +13.93 --+13.61 3"i70 BENCHMAF CONCRETE TEST HOLE LOGS ENGINEER: ARNE H. OJALA, PE WITNESS: AMY VON HONE, RS DATE: 10/29/97 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS LV1 ELEV. 0" 1 2.7' 0 & A 12" B LS 10YR 5/6 36" 9.7' C1 SL 2.5Y 5/6 72" 6.7' C2 MS 135" OBS WATER 144" 2.5Y 5/6 0.7' UNCLE V \ ROBERTS COVE LOCATION MAP NO SCALE ASSESSORS MAP 9 PARCEL 6 SETBACKS: FRONT = 25' SIDE = 12' REAR = 20' REF. LCP 4075 FLOOD ZONE: B & Al2 EL. 10 APPROVED BOARD OF HEALTH DATE MA 01/ 508-362-4541 lox 506 362-9880 down cape engineering, inc. CIVIL ENGINEERS LAND SURVEYORS 939 Main st. yarmouth, no 02675 (WEST) YARMOUTH (GREAT ISLAND) PREPARED FOR: COLIN PHIPPS 20 0 20 40 60 Feet SCALE: 1" = 20' DATE: JANUARY 10, 2003 3 TE ELEV - 14.03' V NOTES: i' -Fr37-� NOTE: CLIVUS SYSTEM PROPOSED SEPTIC DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED_ ) _ 1. DATUM IS NGVD (RM 31) 3DESIGN FLOW: 2_ BEDROOMS (66' GPD) 46_2 GPD 2. MUNICIPAL WATER IS NOT AVAILABLE USE A 462 GPD DESIGN FLOW *40% REDUCTION ALLOWED 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. ' SEPTIC TANK: 462 GPD (_2 _) = 924 GALLONS 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 ^moo 5. PIPE JOINTS TO BE MADE WATERTIGHT. USE A 1500_ GALLON SEPTIC TANK 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. LEACHING: ENVIRONMENTAL CODE TITLE V. SIDES: _____ NIA______ (__) _ GPD 7• THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE 1' ____ USED FOR LOT LINE STAKING. o BOTTOM:_____ 32 x 20 (_74) = 473 GPD 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. N TOTAL: 640 _ S F _473 GPD 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT / USE 32' x 20' LEACH FIELD OF PIPE AND STONE AS SHOWN INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CESSPOOLS TO BE PUMPED AND REMOVED. 1� 3.24 LEGEND 11. ROOF RUNOFF TO BE DIRECTED TO CISTERNS \ WHITE CEDAR ROAD 100.0 PROPOSED SPOT ELEVATION 10 (UNCONSTRUCTED) SITE PLAN 100x0 EXISTING SPOT ELEVATION 100 OF 74 WHITE CEDAR ROAD PROPOSED CONTOUR 100 - EXISTING CONTOUR IN THE TOWN OF: APPROVED BOARD OF HEALTH DATE MA 01/ 508-362-4541 lox 506 362-9880 down cape engineering, inc. CIVIL ENGINEERS LAND SURVEYORS 939 Main st. yarmouth, no 02675 (WEST) YARMOUTH (GREAT ISLAND) PREPARED FOR: COLIN PHIPPS 20 0 20 40 60 Feet SCALE: 1" = 20' DATE: JANUARY 10, 2003 3 TE