HomeMy WebLinkAbout83-1638LEGEND 100.0 PROPOSED SPOT ELEVATION 100x0 EXISTING SPOT ELEVATION 100 PROPOSED CONTOUR - 10o - EXISTING CONTOUR 02-225 TOP FNDN AT EL. 12.0' MIN SYSTEM PROFILE TEST HOLE LOGS , ACCESS COVER TO WITHIN 6" OF FIN. GRADE _ (NOT TO SCALE) PROVIDE INSPECTION PORT WITHIN SEPTIC DESIGN: (GARBAGE DISPOSER IS NOT AL OWED _) ACCESS COVER (WATERTIGHT) TO 6" OF FINISH GRADE ENGINEER: TED DUMAS, RS 5_ BEDROOMS (110 GPD = 550 GPD 11 Q' MINIMUM .75' OF COVER OVER PRECAST WITHIN 6" OF FIN. GRADE AFT RD. DESIGN FLOW: ) 2% SLOPE REQUIRED OVER SYSTEM 9 75, WITNESS: COLLEEN PELLEY USE A 550 GPD DESIGN FLOW =v 4/24 99 !_ RUN TME CF7'EL DATE: / SEPTIC TANK: 550 GPD ( 2 ) = 1100 9.50' FOR FIRST 2' 2" DOUBLE WASH PEASTONE 0.75' min cover < 2 MIN/INCH o i 1500 9 0, PERC. RATE = z u USE A 1500 GALLON SEPTIC TANK 83' _ LEACHING: 9'08'1213jAFTLE SCLASS I SOILS P# N A .82' 0000 8.65' 0 8.58' SIDES: / MIN ELEV, a 62.25 x 12 (.74�= 552 ( %SLOPE) �6" CRUSHED STONE OR MECHANICAL 8�$ 0.58' ? 8 p, L 1u] SHORE SIDE DR. 7 BOTTOM: COMPACTION. (15.221 i2)) MIN -_1.1;M 0" 8.6' TOTAL: 747 S.F. 455 GPD DEPTH OF FLOW = 4' (-L% SLOPE) SLOPE) USE 62.25' x 12' LEACH FIELD OF 2 ROWS EACH OF 9 TEE SIZES: 10„ 3/4" TO 1 1/2" DOUBLE WASHED STONE FILL Lacus _STANDARD INFILTRATORS. EACH, WITH 2' STONE AT SIDES, INLET DEPTH = 2.3' BETWEEN ROWS AND 3' AT -ENDS OUTLET DEPTH = 14" 25 LOCATION MAP NTS A APPROVED DATE FOUNDATION- 14' SEPTIC TANK 1' D' BOX 3' LEACHING 5 LS FACILITY 31" 10YR 3/3 ASSESSORS MAP 26 PARCEL 142 BOARD OF HEALTH NIN DIS RICT: R25 B YARD SETBACKS: MA LS FRONT = 30' USE ADJUSTED WATER AT ELEV. 3.0' NOTE: DWELLING FOOTINGS MUST BE MIN. 2' ABOVE10YR 4/6 SIDE = 15' (TIDALLY INFLUENCED) 38" 5.4' ADJUSTED GROUNDWATER ELEVATION (I.E. BASE OF FOOTING TO BE AT MINIMUM ELEVATION OF 5.0') FLOODZONE FOUNDATION DESIGN BY OTHERS I PROP. ROCK RETAINING WALL, TOP AT EL. 9.0'. PROVIDE 40 MIL LINER ALONG INTERIOR OF WALL, TOP AT EL. 9.0', BOTTOM AT EL. 5.0' IF RESERVE UTILIZED, WATERLINE MUST BE SLEEVED 7.4 FOR ENTIRE LENGTH 7.4 5' REMOVAL OF UNSUITABLE SOIL REQUIRED 7.4 AROUND PERIMETER LEACHING FACILITY, DOWN TO SUITABLE SOI LAYER. REPLACE WITH CLEAN MED. SAND. DRI'JE sIDE � Y�OQY r -f- 7 o C r r r rr r , rr BENCH MARK - TOP OF CONC. BOUND. ELEV. = 8.3 (NGVD) rr r O 7 O+ 8.2 L1 rr r / W rT 80 69rjFi 0 r r 8.0 / S�RJF. L �\{ +8 8 : PIT 8. \ 5 PA CH PROVIDE 2' W.x �Po 2' DEEP x 50' LONG STON g. TRENCH .� - s PITCH 2�, l 0\ �' + 8.8 r r \ rr EXIST. DWELL. � FANG y'/Xi OF �P-/ PRSP SoO� G�PSS / X x�4 V '7.6 0 r r r r r r 3Ay r r r r CRAWLS_PACE r FLOOR THIS AREA TO BE r >\ r MIN. 9.0' EL r r r r r + 9.0 r �/ rr r rr r r 5 fir I LOT 8 + 9.0 24,479± SO. FT. I ?V0? ,pN L• \� 9.4 I PROP $1AQE gt6c PROP. DECK � S P / X GFLP + .2 Ja 9.3 9.8 X� P PRF' G�Pc,S eSPGN PROPOSED WOOD ELEVATED 5.6 BOARDWALK OVER EXIST. PATH s 1 6 EXIST. LANDING/STAIRS 9.6 O. / .4 ARF,P 111 -t1 �� PSS 11 0F'PGN G� 1 1.7 ''a O .3 1O0 0.0 6 tio� N s.e EXIST. LANDING/STAIRS �6 / FLOODZONE V9 EL. 14 C MS $4 OBS WATER 1.3' 89" 2.5Y 7/3 1.18' REAR = 20' PLAN REF. - LCP 21122A FLOOD ZONE: V15 EL. 16, V9 EL. 14 AND A9 EL. 10 (HOUSE IS IN FLOODZONE A9 EL. 10) LOT COVERAGE: DECK AND DWELL. = 18% TEST HOLE LOGS OF 25 SHORE SIDE DRIVE ENGINEER: AH OJALA, PE DATE: 5/7/03 IN THE TOWN OF: PERC. RATE _ < 2 MIN/INCH (SOUTH) YARMOUTH CLASS I SOILS P# PREPARED FOR: FRAN POLITO NOTES: 1. DATUM IS NGVD 2. MUNICIPAL WATER IS AVAILABLE 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE 7.5YR 5/6 USED FOR LOT LINE STAKING. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BF RACKFILI FD OR CONCEALED WITHOUT MS INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED S/- FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE OBS WATER LOvAT10N OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR 90" TO COMMENCEMENT OF WORK, 11. PROVIDE DRYWELLS TO CONTAIN ALL ROOF RUN-OFF TO INCLUDE ROOF OVER SHADEDECK TI TLE 5 SITE PLAN TEST HOLE LOGS OF 25 SHORE SIDE DRIVE ENGINEER: AH OJALA, PE DATE: 5/7/03 IN THE TOWN OF: PERC. RATE _ < 2 MIN/INCH (SOUTH) YARMOUTH CLASS I SOILS P# PREPARED FOR: FRAN POLITO 20 0 20 40 60 SCALE: 1 " = 20' DATE: MAY 7, 2003 REV 7/11/03 (DIST) REV 7/22/03 (DRYWELL NOTE) _ REV 9/30/03 (SAS) REV 10/31/03 (SLAB) ZN FMAS`s9 REV 11/03/03 (DECK ROOF) •�gDi_6/8/04 (SAS, DRAIN.) off 508-362-4541 fax 508 362-9880 down cape engineering, inc, CIVIL ENGINEERS LAND SURVEYORS 939 Clain St. yarmouth, ma 02675 IUDELEV. p" 8.5' FILL 16" E MS 18" IOYR 7/1 B LS 32" 7.5YR 5/6 5.8' C MS 2.5Y 6/6 76" OBS WATER 2.2' 1.0' 90" 20 0 20 40 60 SCALE: 1 " = 20' DATE: MAY 7, 2003 REV 7/11/03 (DIST) REV 7/22/03 (DRYWELL NOTE) _ REV 9/30/03 (SAS) REV 10/31/03 (SLAB) ZN FMAS`s9 REV 11/03/03 (DECK ROOF) •�gDi_6/8/04 (SAS, DRAIN.) off 508-362-4541 fax 508 362-9880 down cape engineering, inc, CIVIL ENGINEERS LAND SURVEYORS 939 Clain St. yarmouth, ma 02675 02-225 TOP FNDN AT EL. 12.0' MIN SYSTEM PROFILE ACCESS COVER TO WITHIN 6" OF FIN. GRADE (NOT TO SCALE) ACCESS COVER (WATERTIGHT) TO 11.0' MINIMUM .75' OF COVER OVER PRECAST wrrHIN 6" OF FIN. GRADE 2% SLOPE REOUIRED OVER SYSTEM 9.50' %1pR FP1RS C2yEL / 2" DOUBLEH WASPEAS - PROPOSED 1500 / 9.08' GALLON SEPTIC ! 8.83' TANK (H- 1 ) \ GAS -`� � � � BAFFLE �� o 8.82 MIN (-.Z-% SLOPE) \_6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 123) MIN DEPTH OF FLOW = 4' ( % SLOPE) ( % SLOPE) TEE SIZES: 101, INLET DEPTH = OUTLET DEPTH = 14„ FOUNDATION- 14' SEPTIC TANK 1' D' BOX IF RESERVE UTILIZED, WATERLINE MUST BE SLEEVED FOR ENTIRE LENGTH I PROVIDE INSPECTION PORT WITHIN 6" OF FINISH GRADE 9.75' 0.75' min cover 9.0' 0.58' 3/4" TO 1 1/2" DOUBLE WASHED STONE 3' LEACHING FACILITY NOTE: DWELLING FOOTINGS MUST BE MIN. 2' ABOVE ADJUSTED GROUNDWATER ELEVATION (I.E. BASE OF FOOTING TO BE AT MINIMU� ELEVATION OF 5.0') FLOODZONE FOUNDATION GESIGN BY OTHERS PROP. ROCK RETAINING WALL, TOP AT EL. 9.0'. PROVIDE 40 MIL LINER ALONG INTERIOR OF WALL, TOP AT EL. 9.0', BOTTOM AT EI.. 5.0' h 7.4 ,7.4 5' REMOVAL OF I-'NSUITABLE SOIL REQUIRED �7.4 AROUND PERIMETER OF LEACHING FACILITY, 1 DOWN TO SUITAPLE SOIL LAYER. REPLACE 1 WITH CLEAN MF.D. SAND. X7.6 SR'qIE 5L�E0 00 S 00 , T i BENCH MARK - TOP OF CONC. 3 - BOUND. ELEV. = 8.3 (NGVD) ` CRAWR -'rHIC y i �� FLOOR PHIS � 7 O+ 8.2 i AREA TO BE �-7.i�'7 MIN. 9.0' EL W + 9.0 i i X609 \R i 8.0 ytEyJf' / + 8.5 c \ RE q4l& * �o LOT 8 P�fTrbF' + 9.0 24,4791 SO. FT. \.b OY 0 Y 9.4 PITCH Q PROVIDE 2' W,x APo 2' DEEP x 50' ° $HAgE DECK: 9q� LONG STON TRENCH "s PITCH o PROP. DECK 969, / ,1, GRpS i O 5' USE ADJUSTED WATER AT ELEV. 3.0' (TIDALLY INFLUENCED) 9.3 ,.F 9.8 ,F EGGS Of j�� X - PRGP GRPc,S g�PGN ' TEST HOLE LOGS LEGENp 100.0 PROPOSED SPOT ELEVATION SEPTIC DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED ) (_GPD) = 550 DESIGN FLOW: BEDROOMS 5_ 110 GPD 1O0x0 EXISTING SPOT ELEVATION USE A 550 GPD DESIGN FLOW �100 -o PROPOSED CONTOUR SEPTIC TANK: 550 GPD (? ) = 1100 - - USE A 1500 GALLON SEPTIC TANK - 100 - EXISTING CONTOUR di LEACHING: CLASS I SOILS P# N/A SIDES: BOTTOM: 62.25 x 12 (.74) = 552 Q TOTAL: 747 S.F. 455 GPD 011 USE 62.25' x 12' LEACH FIELD OF 2 ROWS EACH OF 9 FILL STANDARD INFILTRATORS- EACH, WITH 2' STONE AT SIDES, - LOCUS 2.3' BETWEEN ROWS AND 3' AT ENDS BOARD OF HEALTH LOCATION MAP NTS A , MA APPROVED DATE 02-225 TOP FNDN AT EL. 12.0' MIN SYSTEM PROFILE ACCESS COVER TO WITHIN 6" OF FIN. GRADE (NOT TO SCALE) ACCESS COVER (WATERTIGHT) TO 11.0' MINIMUM .75' OF COVER OVER PRECAST wrrHIN 6" OF FIN. GRADE 2% SLOPE REOUIRED OVER SYSTEM 9.50' %1pR FP1RS C2yEL / 2" DOUBLEH WASPEAS - PROPOSED 1500 / 9.08' GALLON SEPTIC ! 8.83' TANK (H- 1 ) \ GAS -`� � � � BAFFLE �� o 8.82 MIN (-.Z-% SLOPE) \_6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 123) MIN DEPTH OF FLOW = 4' ( % SLOPE) ( % SLOPE) TEE SIZES: 101, INLET DEPTH = OUTLET DEPTH = 14„ FOUNDATION- 14' SEPTIC TANK 1' D' BOX IF RESERVE UTILIZED, WATERLINE MUST BE SLEEVED FOR ENTIRE LENGTH I PROVIDE INSPECTION PORT WITHIN 6" OF FINISH GRADE 9.75' 0.75' min cover 9.0' 0.58' 3/4" TO 1 1/2" DOUBLE WASHED STONE 3' LEACHING FACILITY NOTE: DWELLING FOOTINGS MUST BE MIN. 2' ABOVE ADJUSTED GROUNDWATER ELEVATION (I.E. BASE OF FOOTING TO BE AT MINIMU� ELEVATION OF 5.0') FLOODZONE FOUNDATION GESIGN BY OTHERS PROP. ROCK RETAINING WALL, TOP AT EL. 9.0'. PROVIDE 40 MIL LINER ALONG INTERIOR OF WALL, TOP AT EL. 9.0', BOTTOM AT EI.. 5.0' h 7.4 ,7.4 5' REMOVAL OF I-'NSUITABLE SOIL REQUIRED �7.4 AROUND PERIMETER OF LEACHING FACILITY, 1 DOWN TO SUITAPLE SOIL LAYER. REPLACE 1 WITH CLEAN MF.D. SAND. X7.6 SR'qIE 5L�E0 00 S 00 , T i BENCH MARK - TOP OF CONC. 3 - BOUND. ELEV. = 8.3 (NGVD) ` CRAWR -'rHIC y i �� FLOOR PHIS � 7 O+ 8.2 i AREA TO BE �-7.i�'7 MIN. 9.0' EL W + 9.0 i i X609 \R i 8.0 ytEyJf' / + 8.5 c \ RE q4l& * �o LOT 8 P�fTrbF' + 9.0 24,4791 SO. FT. \.b OY 0 Y 9.4 PITCH Q PROVIDE 2' W,x APo 2' DEEP x 50' ° $HAgE DECK: 9q� LONG STON TRENCH "s PITCH o PROP. DECK 969, / ,1, GRpS i O 5' USE ADJUSTED WATER AT ELEV. 3.0' (TIDALLY INFLUENCED) 9.3 ,.F 9.8 ,F EGGS Of j�� X - PRGP GRPc,S g�PGN ' TEST HOLE LOGS ENGINEER: TED DUMAS, RS AFT RD. WITNESS: COLLEEN PELLEY DATE: 4/24/99 PERC. RATE _ < 2 MIN/INCH di CLASS I SOILS P# m ELEV,a Q SHORE SIDE DR. 011 r FILL - LOCUS 25" LOCATION MAP NTS A LS $1" 10YR 3/3 ASSESSORS MAP 26 PARCEL 142 ZONING DISTRICT: R25 B YARD SETBACKS: LS FRONT = 30' 38" 10YR 4/6 5.4' SIDE = 15' REAR = 20' PLAN REF. - LCP 21122A C FLOOD ZONE: MS V15 EL. 16, V9 EL. 14 AND A9 EL. 10 (HOUSE IS IN FLOOOZONE A9 EL. 10) 84' OBS WATER 1.3' LOT COVERAGE: DECK AND DWELL. 18% 89" 2.5Y 7/3 TEST HOLE LOGS ENGINEER: AH OJALA, PE DATE: 5/7/03 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS P# ' 1 PROPOSED WOOD ELEVATED 5.6 BOARDWALK OVER EXIST. PATH 7 FF��pTTI ELEV. V s 1 6 EXIST. LANDING/STAIRS 0„ 8.5' EXIST. DWELL. 9.6 O. - - 4 �PREP 111 1. � / FILL 4 RPSS I 1 / / 16" o.1 / g�PG� G 11.7 7 OO 3 / � S 10.1 GRPyS 18" 1OYR 7/1 G1 0o gEP � g 0.oLS 5.8 �6 X � �otiaN 32•, 7.5YR 5/6 5.$' GE X �j EXIST. LANDING/STAIRS �� C CF Y�� PREP �ROx / MS 60GEy /� GRPSS 2.5Y 6/6 4 76' OBS WATER 2.2' FLOODZONE V9 EL. 14 \ \AID v �� SIJ 9o" 1_0' NOTES: 1. DATUM IS NGVD 2. MUNICIPAL WATER IS AVAILABLE 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE 1N ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING. S. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK, 11. PROVIDE DRYWELLS TO CONTAIN ALL ROOF RUN-OFF TO INCLUDE ROOF OVER SHADEDECK TITLE S SITE PLAN of 25 SHORE SIDE DRIVE IN THE TOWN OF: (SOUTH) YARMOUTH PREPARED FOR: FRAN POLITO 20 0 zo 40 6.0 SCALE: 1 " = 20' DATE: MAY 7, 2003 REV 7/11/03 (DIST) REV 7/22/03 (DRYWELL NOTE) REV 9/30/03 (SAS) REV 10/31/03 (SLAB) ASH FMAS,� REV 11/03/03 (DECK ROOF) Ay1� T!", 6/8/04 (SAS, DRAIN.) 'E off 506-362-4541 fox 508 362-9860 I down cape engineering, inc. CIVIL ENGINEERS LAND SURVEYORS 939 main st, yarmouth, ma 02675