HomeMy WebLinkAbout78 Willow Street Proposed Section Views13/4X 1 1 1/4" BCI 31001`5 RIDGE 5IMF50N LSTA 24 RIDGE STRAPS \ EVERY RAFTER 2X 10 @ 16" O.C. (TYP.) R-19 FIBERGLASS INSULATION 2X6 @ 16" O.C. SIMP50N LSTA 18 UPLIFT STRAP 32" O.C. 1/2" CDX SHEATHING (OR EQUAL) 1/211 GWB VAPOR BARRIER TYVEK HOUSEWRAP CEDAR SIDING MATCH EXISTING TRIM (SEE ELEVATIONS CONTINUOUS RIDGE VENT 51MP50N LSTA 24 RIDGE STRAPS EVERY RAFTER 13/4X 1 1 114" BCI 3 1 00f RIDGE ON 4X4 POSTS ASPHALT ROOF SHINGLES MATCH EXIST. 5/8" CDX SHEATHING 15# BUILDING PAPER R-38 FIBERGLASS INSULATION I X FACIA I X FRIEZE MATCH EXISTING R— 19 FIBERGLASS INSULATION 2X4 @ 16" O.C. 51MP50N LSTA 18 UPLIFT STRAP 32" O.C. 1/2" CDX SHEATHING (OR EQUAL) 1/2" GWB VAPOR BARRIER TYVEK HOUSEWRAP CEDAR SIDING MATCH EXISTING TRIM (SEE ELEVATIONS PROPOSED SECTION VIEWS PROPOSED RENOVATION AT 78 WILLOW STREET WEST YARMOUTH, MASSACHUSETTS DRAWN BY: MACINNES CONSULTING, LLC EAST SANDWICH, MA 02537 www.macinnesconsulting.com (508)274-2091 EXISTING CMU FND. — WALL ON CONTINUOUS 12"X24" CONCRETE FOOTING (TYP.) (SEE DETAIL) C 2X 10 @ 16" O.C. 2X8 COLLAR TIES @ 16" O.C. 3/4" TSG PLYWOOD SUBFLOOR GLUED * NAILED (TYP.) SECTION VIEW A 2X 12 — 1 1.5' (TYP.) 36"X36"X 12" DP. CONC. FOOTING W/ 6X6 PT FOOTINGS SPACED 7APART CMU FND. WALL ON CONTINUOUS 12"X24" CONCRETE FOOTING (TYP.) (SEE DETAIL) 5OF6 DATE: 8/3/16 SCALE: 1/4"=1' SECTION VIEW B m SHAWN 1`11ACINNES CIVIL NO. 41:23 L CONTINUOUS RIDGE VENT 51MP50N LSTA 24 RIDGE STRAPS EVERY RAFTER (2) 1 3/4X 16" BCI 31 OOFB RIDGE ON4X4 POSTS ASPHALT ROOF SHINGLES MATCH EXIST. 5/8" CDX SHEATHING 15# BUILDING PAPER R-38 FIBERGLASS INSULATION I X FACIA I X FRIEZE MATCH EXISTING R-19 FIBERGLASS INSULATION 2X6 @ 16" O.C. 51MP50N LSTA 18 UPLIFT STRAP 32" O.C. 1/2" CDX SHEATHING (OR EQUAL) 1/211 GWB VAPOR BARRIER TYVEK HOUSEWRAP CEDAR SIDING MATCH EXISTING TRIM (SEE ELEVATIONS EXISTING CMU FND. WALL ON CONTINUOUS 12"X24 CONCRETE FOOTING (TYP.) (SEE DETAIL) EXISTING CMU FND. WALL ON CONTINUOUS 12"X24" CONCRETE FOOTING (TYP.) (SEE DETAIL) NOTES: 1. ALL PROPOSED EXTERIOR WALLS TO BE 2X4 @ 16" O.C. UNLESS OTHERWISE NOTED, 2. ALL PROPOSED INTERIOR WALLS TO BE 2X4 @ 16" O.G. UNLESS OTHERWISE NOTED. 3. ALL PROPOSED WINDOWS TO BE ANDERSEN STORMWATCH 400 SERIES TW W/ APPLIED GRILLS (OR EQUAL). 4. CONTRACTOR SHALL VERIFY ALL WINDOW ROUGH OPENINGS PRIOR TO ORDERING WINDOWS. 5. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. CONTRACTOR ASSUMES RESPONSIBILITY FOR ANY MISSING OR INCORRECT DIMENSIONS NOT BROUGHT TO THE ATTENTION OF THE DESIGNER. G. FASTENING SCHEDULE SEE DETAILS SHEET 6 7. 1 10 MPH EXPOSURE B WCFM GUIDELINES TO BE FOLLOWED - STRAPS, NAILING, RAFTER CLIPS, TIE DOWNS, ETC. 8. BLOCKING AND CONNECTIONS SHALL BE PROVIDED AT PANEL EDGES PERPENDICULAR TO FLOOR FRAMING MEMBERS IN FIRST TWO JOIST SPACES AND SHALL BE SPACED MAXIMUM 4 FEET ON CENTER. 9. FULL HEIGHT SHEATHING TO BE INSTALLED WHERE POSSIBLE. OTHERWISE INTERIOR HORIZONTAL 2X4 BLOCKING SHALL BE USED ON ALL HORIZONTAL SHEATHING SEAMS. I 0.000NTRACTOR TO VERIFY ALL WINDOW ROUGH OPENINGS BEFORE ORDERING WINDOWS. 1 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. CONTRACTOR ASSUMES RESPONSIBILITY FOR ANY MISSING OR INCORRECT DIk,1EN5ION5 NOT BROUGHT TO THE ATTENTION OF THE DESIGNER. (2) 1 3/4X16" BCI 3 1 OOFB RIDGE 2X8 @ 16" O.C. __ j[ 1 2X8 COLLAR TIESCc+? I " O.G. I J! jLl I ! 3/4 TSG PLYWOCIE PUETLO0R' s I GLUED NAILED F) 2X8 @ 16" O.C. (USE EXISTING) CMU FND. WALL ON CONTINUOUS 12"X24" CONCRETE FOOTING (TYP.) (SEE DETAIL) 5OF6 DATE: 8/3/16 SCALE: 1/4"=1' SECTION VIEW B m SHAWN 1`11ACINNES CIVIL NO. 41:23 L CONTINUOUS RIDGE VENT 51MP50N LSTA 24 RIDGE STRAPS EVERY RAFTER (2) 1 3/4X 16" BCI 31 OOFB RIDGE ON4X4 POSTS ASPHALT ROOF SHINGLES MATCH EXIST. 5/8" CDX SHEATHING 15# BUILDING PAPER R-38 FIBERGLASS INSULATION I X FACIA I X FRIEZE MATCH EXISTING R-19 FIBERGLASS INSULATION 2X6 @ 16" O.C. 51MP50N LSTA 18 UPLIFT STRAP 32" O.C. 1/2" CDX SHEATHING (OR EQUAL) 1/211 GWB VAPOR BARRIER TYVEK HOUSEWRAP CEDAR SIDING MATCH EXISTING TRIM (SEE ELEVATIONS EXISTING CMU FND. WALL ON CONTINUOUS 12"X24 CONCRETE FOOTING (TYP.) (SEE DETAIL) EXISTING CMU FND. WALL ON CONTINUOUS 12"X24" CONCRETE FOOTING (TYP.) (SEE DETAIL) NOTES: 1. ALL PROPOSED EXTERIOR WALLS TO BE 2X4 @ 16" O.C. UNLESS OTHERWISE NOTED, 2. ALL PROPOSED INTERIOR WALLS TO BE 2X4 @ 16" O.G. UNLESS OTHERWISE NOTED. 3. ALL PROPOSED WINDOWS TO BE ANDERSEN STORMWATCH 400 SERIES TW W/ APPLIED GRILLS (OR EQUAL). 4. CONTRACTOR SHALL VERIFY ALL WINDOW ROUGH OPENINGS PRIOR TO ORDERING WINDOWS. 5. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. CONTRACTOR ASSUMES RESPONSIBILITY FOR ANY MISSING OR INCORRECT DIMENSIONS NOT BROUGHT TO THE ATTENTION OF THE DESIGNER. G. FASTENING SCHEDULE SEE DETAILS SHEET 6 7. 1 10 MPH EXPOSURE B WCFM GUIDELINES TO BE FOLLOWED - STRAPS, NAILING, RAFTER CLIPS, TIE DOWNS, ETC. 8. BLOCKING AND CONNECTIONS SHALL BE PROVIDED AT PANEL EDGES PERPENDICULAR TO FLOOR FRAMING MEMBERS IN FIRST TWO JOIST SPACES AND SHALL BE SPACED MAXIMUM 4 FEET ON CENTER. 9. FULL HEIGHT SHEATHING TO BE INSTALLED WHERE POSSIBLE. OTHERWISE INTERIOR HORIZONTAL 2X4 BLOCKING SHALL BE USED ON ALL HORIZONTAL SHEATHING SEAMS. I 0.000NTRACTOR TO VERIFY ALL WINDOW ROUGH OPENINGS BEFORE ORDERING WINDOWS. 1 1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. CONTRACTOR ASSUMES RESPONSIBILITY FOR ANY MISSING OR INCORRECT DIk,1EN5ION5 NOT BROUGHT TO THE ATTENTION OF THE DESIGNER.