83-1708 - Site PlanIST FLOOR AT EL. 11.0' SYSTEM PROFILE ACCESS COVER TO WITHIN 6" OF FIN. GRADE (NOT TO SCALE) //--- ACCESS COVER (WATERTIGHT) TO 9 p' MINIMUM .75' OF COVER OVER PRECAST / WITHIN 6" OF FIN. GRADE 2% SLOPE REQUIRED OVER SYSTEM kd, 7.00' PROP CRAWLSP. PROPOSED 1500 6.56, GALLON SEPTIC TANK (H- 10 ) ( 2 % SLOPE) NOTE: FLOODZONE DEPTH OF FLOW = 4, FOUNDATION REQUIRED (DESIGN BY OTHERS) TEE SIZES: INLET DEPTH = 10" OUTLET DEPTH = 14" FOUNDATION- 22' ST - ALARM AND CONTROL PANEL TO BE INSTALLED INSIDE BUILDING. ALARM TO BE ON SEPARATE CIRCUIT FROM PUMP INV. IN 6.26' °7 RUN PIPE LEVEL FOR FIRST 2' ITEE �g cAs 0 .62' 0 8.58' . BAFFLE o 8.79' �� $~ 0.58' 6" CRUSHED STONE OR MECHANICAL o0 COMPACTION. (15.221 [2]) (-L-;, SLOPE) ( % SLOPE). 2" DOUBLE WASHED P PROVIDE INSPECTION PORT WITHIN 6" OF FINISH GRADE - M TEST HOLE LOGS ENGINEER: D.A. OJALA, SE WITNESS: LYNN MULKEEN DATE: 10/27/04 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS P# Q ELEV. Q 3/4" TO 1 1/2" DOUBLE WASHED STONE 0" 65' 0" 6.4' PUMPLEACHING 5 CHAMBER 36 D' BOX 6FACILITY 40 MIL POLY VNYL AND MASTIC ON INSIDE OF 777 00 6.5 PC I ,p I ( f PERVIOUS 9.U' S.3 I � ITH2 DRNEWAY GAR AT EL. 9.25* D i l LO o 7.2 '- - _ J / / + 5.y / o PROPOSED 40 MIL LINER, AT 5' OFF TOP AT ELEVATION 9.0' (CONTINUE FROM INSIDE OF WALL) 6.1 5.5 -K5.8 MOSS ROAD 4 2 l 1 + 5.9 BENCHMARK: USE MAG NAIL AT ELEVATION 5.9' BUOYANCY CALCS: 1500 GAL H-10 (SHOREY) ST WGT. 11480 LBS 1.19' x 10.5 x 5.67 x 62.4 - 4420 (OKAY) 1000 GAL H-10 (SHOREY) PC WGT 8240 LBS 04-290 1.24' x 8.5 x 4.8 x 62.4 = 3157 LBS (OKAY) PROP. 4 SR DWELLING FIRST FLOOR AT OR .ABOVE ELEV. 11.0' LOT 58\ + 5.5 23,621± SQ. + 6.3 PROP. LINER AT EDGE OF ROCK WALL / + 5.1� COBBtEs 132.30' GRAll RrVE CrNfD APPROVED DATE C71 + 5.7 b, ------4 rx 7- + 3.5 BOARD OF HEALTH MA 0 0 2" 2- A LOCUS RADIO (ANE JROAtp) MOS' LOCATION MAP NTS 5'. I -- 1000 GAL. H-10 S/ u t r,cc.�o...� �•• - .:[.- (6) #3 BARS CONT. FOR Uc LS 500 GAL.+ SLOPE TO DRAIN BACK TO PC 2�.; HORIZONTAL REINFORCEMENT T FLOAT SWITCH ALARM ON RESERVE WEEP HOLE 4'6' SETTINGS, PUMP ON CHECK VALVE . ' 5.0' EL.6.5' (PROPOSED) WDRKING RANGE 8' MY RS SRM4 _ '.; #4 BARS 12" O.C. FOR VERTICAL 5.3' SUBMERSIBLE 4/10 HP PUMP B REAR = 20' REINFORCEMENT PUMP OFF 8' SYSTEM (OR EQUAL). �-� - o00 00000 ;E ADJ. WATER AT EL. 3.0' ...6 :.•, 1OYR S/ 8 000000 0000 0000 0000 4.0' 36" . PUMP CHAMBER 1. ENGINEER SHALL INSPECT WHEN REQUIRED EXCAVATION IS 12"4.0' 5' REMOVAL OF UNSUITABLE SOIL BASE EL (NOT TO SCALE) REQUIRED AROUND PERIMETER OF - ;,�t+r-�2g•:..� 3 ENGINEERSHALL INSPECT FOOTING AND REBAR PRIOR TO POURING WATERPROOF/WATERTIGHT LEACHING FACILITY, DOWN TO SUITABLE SOIL LAYER. REPLACE - �.� WITH CLEAN MED. SAND. 4. ENGINEER SHALL INSPECT WHEN CLEAN FILL HAS BEEN PROPERLY NATURAL SOIL OBS WATER _ DEPOSITED OBS WATER 2.2' 5. ENGINEER SHALL INSPECT AND CERTIFY SEPTIC COMPONENTS AND - PROVIDE VENT WITH CHARCOALLrl AND BUGSCREEN (FINAL PLACEMENT WITH - - _ OMEOWNER CONSULTATION) - + �.S_ LANE CONC. RET. WALL (NTS) 2.5Y 6/6 ENGINEER SHALL CERTIFY TO YARMOUTH HEALTH DEPARTMENT THAT / -1-5.4_ THE RETAINING WALL, SEPTIC SYSTEM AND PUMP MECHANISMS HAVE 96" VER H`UTILITIES - - -4- - - 5.8 PLAN. SEPTIC DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED - ) DESIGN FLOW: 4 BEDROOMS - - PROP.6' HIGH CEDAR FENCE - - - USE A 440 GPD DESIGN FLOW 6D - _ 1. DATUM IS NGVD *6.2 7.0 ., 9. 2. MUNICIPAL WATER IS AVAILABLE USE A 1500 GALLON SEPTIC TANK 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. �Q- 1 777 00 6.5 PC I ,p I ( f PERVIOUS 9.U' S.3 I � ITH2 DRNEWAY GAR AT EL. 9.25* D i l LO o 7.2 '- - _ J / / + 5.y / o PROPOSED 40 MIL LINER, AT 5' OFF TOP AT ELEVATION 9.0' (CONTINUE FROM INSIDE OF WALL) 6.1 5.5 -K5.8 MOSS ROAD 4 2 l 1 + 5.9 BENCHMARK: USE MAG NAIL AT ELEVATION 5.9' BUOYANCY CALCS: 1500 GAL H-10 (SHOREY) ST WGT. 11480 LBS 1.19' x 10.5 x 5.67 x 62.4 - 4420 (OKAY) 1000 GAL H-10 (SHOREY) PC WGT 8240 LBS 04-290 1.24' x 8.5 x 4.8 x 62.4 = 3157 LBS (OKAY) PROP. 4 SR DWELLING FIRST FLOOR AT OR .ABOVE ELEV. 11.0' LOT 58\ + 5.5 23,621± SQ. + 6.3 PROP. LINER AT EDGE OF ROCK WALL / + 5.1� COBBtEs 132.30' GRAll RrVE CrNfD APPROVED DATE C71 + 5.7 b, ------4 rx 7- + 3.5 BOARD OF HEALTH MA 0 0 2" 2- A LOCUS RADIO (ANE JROAtp) MOS' LOCATION MAP NTS 5'. I A LS LS ASSESSORS MAP 14 PARCEL 113 ZONING DISTRICT: R-25 6" 1OYR 3/2 1OYR 3/2 YARD SETBACKS: 6" FRONT = 30' SIDE = 15' B B REAR = 20' PLAN REF. - LCP 14426 G LS LS FLOOD ZONE: Al2 EL. 10 ;E ADJ. WATER AT EL. 3.0' 1OYR 5/8 1OYR S/ 8 DALLY INFLUENCED) 30" 4.0' 36" 3.4' REQUIRED INSPECTIONS AND CERTIFICATIONS C 1. ENGINEER SHALL INSPECT WHEN REQUIRED EXCAVATION IS C COMPLETE. 2. ENGINEER SHALL STAKE FOOTING PRIOR TO POURING 3 ENGINEERSHALL INSPECT FOOTING AND REBAR PRIOR TO POURING - MS MS OF WALL 4. ENGINEER SHALL INSPECT WHEN CLEAN FILL HAS BEEN PROPERLY 48" OBS WATER 2.5' 50" DEPOSITED OBS WATER 2.2' 5. ENGINEER SHALL INSPECT AND CERTIFY SEPTIC COMPONENTS AND PUMP MECHANISMS AFTER INSTALLATION 2.5Y 6/6 / 2.5Y 6/6 ENGINEER SHALL CERTIFY TO YARMOUTH HEALTH DEPARTMENT THAT / THE RETAINING WALL, SEPTIC SYSTEM AND PUMP MECHANISMS HAVE 96" -1.5 10$" -2.6' BEEN INSTALLED IN SUBSTANTIAL COMPLIANCE WITH THE APPROVED PLAN. SEPTIC DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED ) DESIGN FLOW: 4 BEDROOMS (110 GPD) = 440 GPD NOTES: USE A 440 GPD DESIGN FLOW 1. DATUM IS NGVD SEPTIC TANK: 440 GPD ( 2 ) = 880 2. MUNICIPAL WATER IS AVAILABLE USE A 1500 GALLON SEPTIC TANK 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. LEACHING: 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 SIDES: N/A 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. BOTTOM: - 40.5 x 15 (.74) = 449 ENVIRONMENTAL CODE TITLE V. TOTAL: 607 S.F. 449 GPD 7. THIS PLAN IS FOR PROPOSED SEPTIC SYSTEM ONLY AND IS NOT TO BE USED FOR ANY OTHER PURPOSE. USE 40.5' x 15' LEACH FIELD OF 2 ROWS OF 6 8, PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. H-10 STANDARD INFILTRATORS EACH, WITH 3' STONE 3.3' 9, COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT AT SIDES, BETWEEEN ROWS AND 1.5' AT ENDS INSPECTION BY BOARD OF HEALTH AND PERMI I SS ON OBTAINED FROM BOARD OF HEALTH. LEGEND TITLE `5 SITE PLAN + 5.9 700.0 PROPOSED SPOT ELEVATION °F 36 MOSS ROA D 0 cV 100+0 EXISTING SPOT ELEVATION IN THE TOWN OF: MO 0 PROPOSED CONTOUR (WEST) YARMOUTH - 100 - EXISTING CONTOUR PREPARED FOR: SAM TRAYWICK 20 0 20 40 80 SCALE: 1" = 20' DATE: DECEMBER 7, 2004 clown cape engineering, ill F� CIVIL ENGINEERS VLAND SURVEYORS 939 main st• yarmouth, ma 02675 ",l. I,2`jaS. ARNE H. OJALA, P.E., P.L.S. DATE