Loading...
83-1708 - Site Plan0021ST FLOOR AT EL. 11.0' SYSTEM PROFILE TEST H❑LE L❑GS . , ACCESS COVER TO WITHIN 6" OF AN. GRADE (NOT TO SCALE)li PROVIDE INSPECTION PORT WITHIN 6" OF FINISH GRADE D.A. OJALA, SE ACCESS COVER (WATERTIGHT) TO ENGINEER: 9 O' MINIMUM .75' OF COVER OVER PRECAST / WITHIN 6" OF FIN. GRADE 2% SLOPE REQUIRED OVER SYSTEM LYNN MULKEEN 9.75 WITNESS: m 2" DOUBLE WASHED PEASTONE 10/27/04 RUN PIPE LEVEL / DATE: 7 00' _ FOR FIRST 2' ! 9.0' < 2 MIN/INCH LROPOSED 1500 PERC. RATE _ PROP CRAWLSP. a _fT ALLON SEPTIC z6.31' � TEE �g CLASS I SOILS P# 6.56'NK (H- 10) GAS o 8.79' 0.5 g.62' 8.58' .'a BAFFLE o 8.79 80 0.58' o 0�� 8.0' (2 % SLOPE) \_6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [2]) 4 ELEV. � 6.4' NorE: FLOoozoNE DEPTH OF FLOW = 4 ( 1 % SLOPE) ( % SLOPE) 3/4" TO 1 1/2" DOUBLE WASHED STONE 0" 6_5' 0" FOUNDATION REQUIRED TEE SIZES: (DESIGN BY OTHERS) 10" INLET DEPTH = OUTLET DEPTH = 14" FOUNDATION- 22' ST ALARM AND CONTROL PANEL TO BE INSTALLED IN BUILDING. ALARM TD BE ON SEPARATE CIRCUIT FROM PUMP ALARM ON FLOAT SWITCH SETTINGS, PUMP ON WORKING RANGE PUMP OFF 1000 GAL. H-10 500 GAL.+ RESERVE 5' PUMP 36' D' BOX 6' LEACHING CHAMBER FACILITY 40 MIL POLY VINYL AND - MASTIC ON INSIDE OF EL. 9.0' 10"- RETAINING WALL SLOPE TO DRAIN BACK TO PC WEEP HOLE CHECK VALVE 5' 2" 6" BARS CONT. FOR USE ADJ. WATER AT EL. 3.0' TAIL REINFORCEMENT (TIDALLY INFLUENCED) 30" MYERS SRM4 ;" #4 BARS 12" O.C. FOR VERTICAL SUBMERSIBLE 4/10 HP PUMP REINFORCEMENT SYSTEM (OR EQUAL) .6:.. PUMP CHAMBER 5' REMOVAL OF UNSUITABLE SOIL 4.0' BASE EL. (NOT TO SCALE) REQUIRED AROUND PERIMETER OF�'�-.` LEACHING FACILITY, DOWN TO .. 4- 72- WATERPROOF/WATERTIGHT SUITABLE. SOIL LAYER. REPLACE m [[ WITH CLEAN MED. SAND. NATURAL SOIL PROVIDE VENT WITH CHARCOAL6p4l Eii- AND BUGSCREEN (FlNAL PLACEMENT WTH --__ CONC. RET. WALL (NTS) OMEONNER CONSULTATION) RADIO LANE OVER y= 5 8 TILITIES - _ - - ® - - PROP. 6' HIGH CEDAR FENCE - 6.2 7.0 9. r s.o '0 206.001 - - v0 + 6.5 moo. PC � I i M f Wn PROP. 9-0' 5.3 O , L [TH2 PERVIOUS. DRIVEWAY GAR AT EL. 9.25'l 0 r l ® �I / / IQ 'O + 7.2 + 5. o PROPOSED 40 MIL // \ LINER, AT 5' OFF SAS, / TOP AT ELEVATION 9.0' / 0� (CONTINUE FROM / INSIDE OF WALL) s Q' L p3.77' 5.5 O \ -K5.8 MOSS ROAD + 5.9 BENCHMARK: USE MAG NAIL AT ELEVATION 5.9' 104-290 O ST + .2 PROP. 4 BR DWELLING FIRST FLOOR AT OR ABOVE ELEV. 11.0' + 5.5 PROP. LINER AT EDGE OF ROCK WALL LOT 58 23,621± SQ. + 6.3 a + 5.7 a COgBLe 4,8 132.30' GRAVEL pRl CrIVEp " 177' BUOYANCY CALCS: + 3.5 1500 GAL H-10 (SHORED ST WGT. 11480 LBS 1.19' x 10.5 x 5.67 x 62.4 - 4420 (OKAY) 1000 GAL H-10 (SHOREY)PC WGT 8240 Les BOARD OF HEALTH 1.24' x 8.5 x 4.8 x 62.4 = 3157 LBS (OKAY) MA APPROVED DATE 48" 96" A LS 1OYR 3/2 B LS 1CYR 5/8 C MS OBS WATER 2.5Y 6/6 0 2" A LS 6" 1OYR 3/2 B LS 1OYR 5/8 � SOD f l aIIJ LOCATION MAP NTS ASSESSORS MAP 14 PARCEL 113 ZONING DISTRICT: R-25 YARD SETBACKS: FRONT = 30' SIDE = 15' REAR = 20' PLAN REF. - LCP 14426 G FLOOD ZONE: Al2 EL. 10 4' REQUIRED INSPECTIONS AND CERTIFICATIONS 1. ENGINEER SHALL INSPECT WHEN REQUIRED EXCAVATION IS SEPTIC DESIGN: C COMPLETE. DESIGN FLOW: 4 BEDROOMS (110 GPD) = 2. ENGINEER SHALL STAKE FOOTING PRIOR TO POURING USE A 440 GPD DESIGN FLOW 3. ENGINEER SHALL INSPECT FOOTING AND REBAR PRIOR TO POURING SEPTIC TANK: 440 GPD (2 ) = 880 MS OF WALL SEPTIC TANK 4. ENGINEER SHALL INSPECT WHEN CLEAN FILL HAS BEEN PROPERLY !.5'. 50" OBS WATER DEPOSITED 2.2' 5. ENGINEER SHALL INSPECT AND CERTIFY SEPTIC COMPONENTS AND N/A PUMP MECHANISMS AFTER INSTALLATION BOTTOM: 40.5 x 6 2.5Y 6/6 ENGINEER SHALL CERTIFY TO YARMOUTH HEALTH DEPARTMENT THAT TOTAL: 607 S.F. 449 GPD THE RETAINING WALL, SEPTIC SYSTEM AND PUMP MECHANISMS HAVE 108" LEACH FIELD OF 2 ROWS BEEN INSTALLED IN SUBSTANTIAL COMPLIANCE WITH THE APPROVED -1.5 INFILTRATORS EACH, WITH -2.6' PLAN. SEPTIC DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED -. ) DESIGN FLOW: 4 BEDROOMS (110 GPD) = 440 GPD USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2 ) = 880 USE A 1500 GALLON SEPTIC TANK LEACHING: SIDES: N/A BOTTOM: 40.5 x 15 (.74) = 449 TOTAL: 607 S.F. 449 GPD USE 40.5' x 15' LEACH FIELD OF 2 ROWS OF 6 H-10 STANDARD INFILTRATORS EACH, WITH 3' STONE AT SIDES, 3.3' BETWEEEN ROWS AND 1.5' AT ENDS t+ 5,9 LEGEND O 100.0 PROPOSED SPOT ELEVATION O cy 100+0 EXISTING SPOT ELEVATION 100 0 PROPOSED CONTOUR - 100 - EXISTING CONTOUR �{ en eoe-xz-ws4l '�T/ rm we �u-seao down cape engineering, inc, CIVIL ENGINEERS LAND SURVEYORS 939 main St. yarmouth, ma 02675 ? NOTES: 1. DATUM IS NGVD 2. MUNICIPAL WATER IS AVAILABLE 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED SEPTIC SYSTEM ONLY AND IS NOT TO BE USED FOR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. TITLE S `SITE PLAN OF 36 :• MOSS ROAD IN THE TOWN OF: (WEST) YARMOUTH PREPARED FOR: SAM TRAYWICK 20 0 20 40 80 SCALE: 1" = 20' DATE: DECEMBER 7, 2004 ��(. 11241as , ARNE H. OJALA, P.E., P.L.S. DATE ,