Loading...
HomeMy WebLinkAbout83-1716 - Site PlanLEGEND 100.0 PROPOSED SPOT ELEVATION 100x0 EXISTING SPOT ELEVATION 100 PROPOSED CONTOUR - 100 EXISTING CONTOUR PROVIDE 4" U AND SEEDED (BOTH SIDES) 04-219 SEPTIC DESIGN: (GARBAGE DISPOSER Is NOT ALLOWED ) DESIGN FLOW: 4 BEDROOMS (110 GPD) = 440 GPD 440 TOP FNDN AT EL. 25.76' SYSTEM PROFILE ., /-ACCESS COVER TO WITHIN 6" OF FIN. GRADE (NOT TO SCALE) ACCESS COVER (WATERTIGHT) TO MINIMUM .75' OF COVER OVER PRECAST WITHIN 6" OF FIN. GRADE/­ 2% RADE2% SLOPE REQUIRED OVER SYSTEM TEST HOLE LOGS PROVIDE INSPECTION PORTS (ONE PER ROW OF EQUALIZERS) ENGINEER: D.A. OJALA, SE WITNESS: AMY VON HONE, RS USE A GPD DESIGN FLOW 24.0' - 25.0' g/1/04 * _RUN PIPE LEVEL 2" DOUBLE WASHED PEASTONE DATE: SEPTIC TANK: 440 GPD (�) = 880 23.15' FOR FIRST 2' �iPROVDE MIN. 1' COMPACTED 2 MIN/INCH USE A 1500 GALLON SEPTIC TANK PROPOSED 1500 II II / 22.6' COVER IN DRIVEWAY AREA PERC. RATE _ GALLON SEPTIC / I LEACHING 22.95 TANK (H- 10) 2G S 0'�-� o CLASS SOILS BASE FOOTINGS 22.52 22.2' SIDES: N/A MINIMUM I I .M ELEV. •' :.. BAFFLE 22.69' �� , goQ 0.5' 2 25 x 12 74 = 444 1 ` X250 0000$ ELEV. BOTTOM: ( ) (' ) (_% SLOPE) �6" CRUSHED STONE OR MECHANICA-L + 4 COMPACTION. (15.221 [2]) EQUALIZER 24 HD 0" 247, TOTAL: 600 S.F. 444 GPD DEPTH OF FLOW = 4' A USE (2) 25' x 12' LEACH FIELDS EACH CONSISTING TEE SIZES: (-!-% SLOPE) (-i--% SLOPE) 3/4" TO 1 1/2" DOUBLE WASHED STONE P SL = OF 2 ROWS OF 3 EQUALIZER 24 HD'S WITH S STONE INLET DEPTH 1 10"" 10" 1OYR 4/2 AT SIDES, 3.5' BETWEEN ROWS AND NONE AT ENDS OUTLET DEPTH = 5' FOUNDATION- 10' SEPTIC TANK -- 1' D' BOX 34' LEACHING B FACILITY LS BOARD OF HEALTH 1OYR 5/6 21.7' *THIS IS A PROPOSED MINIMUM USE ADJ. WATER AT EL. 16.7' 36" MA INVERT ELEVATION OUT OF APPROVED DATE FOUNDATION. PLUMBER/CONTRACTOR CROWN 1/8" TO 1/2" NATIVE WASHED STONE 4" PROCESSED STONE SAND BASE PERVIOUS DRNEWAY CROSS SECTION (NOT TO SCALE) TOP CULVERT^ PIPE / BEG DITCH 1.r wr y 1 770 0 yam+ r h y 1 r ! OLD DON r r #5 OF ,/ SCHALL \ i FLAG 50- ; / # i zu PROP. BERM / /r#3. zz (BOT SIDES OFDRIVE;/ r PROP ADD / ..... %! 2 4z # ✓o Q\ ` PROP. WORK LIMIT LINE 4�" ¢gyp p � EXIS . 10v LEACH. UIT NAIL IN 1 #16 UTILITY POLE / PROP. WORK LIMIT LINE TSq ELEV. 1.o _ r kf \ ♦ `WAy PROP. 20.7 it 12 �. Sl�T F♦ \ \ , PAVED I i # fiyCF ♦ `\ I_ DRIVE e•'PIN LOTS 11 & 3 13 � `. 26,173 tSF ♦ ♦ ` � / #17lY ' 123 , I $D 5' 6• PINE r #10A r #10 Z ISOLATED za_ j WETLAND 24 , 1 �Q - 6616 SF PUMP AND EMOVE 1 i1 EXIST SE C TANK , #9 I #2 ` , , i #7 #4 ` r -' #6 #4� - TO CONFIRM FEASIBILITY GIVEN PROPOSED ADDITIONS' PLUMBING REQUIREMENTS CONTACT ENGINEER IF NOT FEASIBLE (PUMP DESIGN WOULD BE NECESSARY) PROVIDE MIN. 2' COVER OVER EXIT PIPING (OR INSTALL INSULATING BLANKET OVER PIPING TO SEPTIC TANK) C PERC •* NOTE: BASE OF FOOTINGS FOR NEW ADDITIONS SHALL BE MINIMUM 2' ABOVE THE M/F ADJUSTED GROUNDWATER ELEVATION SAND 5' REMOVAL OF UNSUITABLE SOIL r CRAWL REQUIRED AROUND PERIMETER OF 1 / 9 SUITABLE SOIL LAYER. REPLACE RE-ROUTE GASLINE WITH CLEAN MED. SAND. ENGINEER Iv LEGEND 100.0 PROPOSED SPOT ELEVATION 100x0 EXISTING SPOT ELEVATION 100 PROPOSED CONTOUR - 100 EXISTING CONTOUR PROVIDE 4" U AND SEEDED (BOTH SIDES) 04-219 SEPTIC DESIGN: (GARBAGE DISPOSER Is NOT ALLOWED ) DESIGN FLOW: 4 BEDROOMS (110 GPD) = 440 GPD 440 TOP FNDN AT EL. 25.76' SYSTEM PROFILE ., /-ACCESS COVER TO WITHIN 6" OF FIN. GRADE (NOT TO SCALE) ACCESS COVER (WATERTIGHT) TO MINIMUM .75' OF COVER OVER PRECAST WITHIN 6" OF FIN. GRADE/­ 2% RADE2% SLOPE REQUIRED OVER SYSTEM TEST HOLE LOGS PROVIDE INSPECTION PORTS (ONE PER ROW OF EQUALIZERS) ENGINEER: D.A. OJALA, SE WITNESS: AMY VON HONE, RS USE A GPD DESIGN FLOW 24.0' - 25.0' g/1/04 * _RUN PIPE LEVEL 2" DOUBLE WASHED PEASTONE DATE: SEPTIC TANK: 440 GPD (�) = 880 23.15' FOR FIRST 2' �iPROVDE MIN. 1' COMPACTED 2 MIN/INCH USE A 1500 GALLON SEPTIC TANK PROPOSED 1500 II II / 22.6' COVER IN DRIVEWAY AREA PERC. RATE _ GALLON SEPTIC / I LEACHING 22.95 TANK (H- 10) 2G S 0'�-� o CLASS SOILS BASE FOOTINGS 22.52 22.2' SIDES: N/A MINIMUM I I .M ELEV. •' :.. BAFFLE 22.69' �� , goQ 0.5' 2 25 x 12 74 = 444 1 ` X250 0000$ ELEV. BOTTOM: ( ) (' ) (_% SLOPE) �6" CRUSHED STONE OR MECHANICA-L + 4 COMPACTION. (15.221 [2]) EQUALIZER 24 HD 0" 247, TOTAL: 600 S.F. 444 GPD DEPTH OF FLOW = 4' A USE (2) 25' x 12' LEACH FIELDS EACH CONSISTING TEE SIZES: (-!-% SLOPE) (-i--% SLOPE) 3/4" TO 1 1/2" DOUBLE WASHED STONE P SL = OF 2 ROWS OF 3 EQUALIZER 24 HD'S WITH S STONE INLET DEPTH 1 10"" 10" 1OYR 4/2 AT SIDES, 3.5' BETWEEN ROWS AND NONE AT ENDS OUTLET DEPTH = 5' FOUNDATION- 10' SEPTIC TANK -- 1' D' BOX 34' LEACHING B FACILITY LS BOARD OF HEALTH 1OYR 5/6 21.7' *THIS IS A PROPOSED MINIMUM USE ADJ. WATER AT EL. 16.7' 36" MA INVERT ELEVATION OUT OF APPROVED DATE FOUNDATION. PLUMBER/CONTRACTOR CROWN 1/8" TO 1/2" NATIVE WASHED STONE 4" PROCESSED STONE SAND BASE PERVIOUS DRNEWAY CROSS SECTION (NOT TO SCALE) TOP CULVERT^ PIPE / BEG DITCH 1.r wr y 1 770 0 yam+ r h y 1 r ! OLD DON r r #5 OF ,/ SCHALL \ i FLAG 50- ; / # i zu PROP. BERM / /r#3. zz (BOT SIDES OFDRIVE;/ r PROP ADD / ..... %! 2 4z # ✓o Q\ ` PROP. WORK LIMIT LINE 4�" ¢gyp p � EXIS . 10v LEACH. UIT NAIL IN 1 #16 UTILITY POLE / PROP. WORK LIMIT LINE TSq ELEV. 1.o _ r kf \ ♦ `WAy PROP. 20.7 it 12 �. Sl�T F♦ \ \ , PAVED I i # fiyCF ♦ `\ I_ DRIVE e•'PIN LOTS 11 & 3 13 � `. 26,173 tSF ♦ ♦ ` � / #17lY ' 123 , I $D 5' 6• PINE r #10A r #10 Z ISOLATED za_ j WETLAND 24 , 1 �Q - 6616 SF PUMP AND EMOVE 1 i1 EXIST SE C TANK , #9 I #2 ` , , i #7 #4 ` r -' #6 #4� - TO CONFIRM FEASIBILITY GIVEN PROPOSED ADDITIONS' PLUMBING REQUIREMENTS CONTACT ENGINEER IF NOT FEASIBLE (PUMP DESIGN WOULD BE NECESSARY) PROVIDE MIN. 2' COVER OVER EXIT PIPING (OR INSTALL INSULATING BLANKET OVER PIPING TO SEPTIC TANK) C PERC •* NOTE: BASE OF FOOTINGS FOR NEW ADDITIONS SHALL BE MINIMUM 2' ABOVE THE M/F ADJUSTED GROUNDWATER ELEVATION SAND 5' REMOVAL OF UNSUITABLE SOIL r CRAWL REQUIRED AROUND PERIMETER OF 1 / LEACHING FACILITY, DOWN TO SUITABLE SOIL LAYER. REPLACE RE-ROUTE GASLINE WITH CLEAN MED. SAND. ENGINEER Iv TO INSPECT AND CERTIFY QY REMOVAL. N r o i / !rCL ! 0,/ P.E., P.L.S. DATE 9 p REMOVE pp, I PROVIDE VENT WITH CHARCOAL FILTER AND BUGSCREEN (FINAL PLACEMENT WITH o ' HOMEOWNER CONSULTATION) / y / nm r CRAWL OdA1A � �+ _' 1 / SPACE RE-ROUTE GASLINE / rr" Iv �2 QY SLAB N r o ! / !rCL ! 0,/ P.E., P.L.S. DATE REMOVE r / u EXIST. DECK r. ' R E�PROP. i � RESERVE AREA (450 SF) r Err *SHOULD PRIMARY SYSTEM FAIL, REPLACE EXISTING r Y � DWELLING CONTAMINATED SOILS TF=25.76' r` /G / � r r � Ur PROP ' i1DDN EXIST.INV \ f OUT r ELEV=22.26'' i' CRAWLSPACE 0 / r v 9.8' OBS. WATER 14.9' 2.5Y 6/4 123" 14.5' N BENCHMARK: USE C. BASIN AT ELEVATION 25.0' H33G3311R3 mmr 19+V r-MMUCL3 LO OC LJ ZONING DISTRICT: R 40 YARD SETBACKS: FRONT = 30' SIDE = 20' REAR = 20' PLAN REF. - LCP 34907 A FLOOD ZONE: C GROUNDWATER FOUND AT EL. 14.9' ADJ: 1.8' (SDW 252, ZONE A) USE ADJ. WATER AT EL. 16.7' NOTES: 1. DATUM IS ASSUMED 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRivR TO COMMENCEMENT OF WORK. 11. WETLAND FLAGGED BY HAMLYN CONSULTING 12. ROOF RUN OFF TO BE DIRECTED TO DRYWELLS OR STONE TRENCHES TITLE 5 SITE PLAN OF 147 CENTER STREET IN THE TOWN OF: YARMOUTH (PORT) PREPARED FOR: RONALD & DEBORAH TRACHTENBERG 20 0 20 40 60 SCALE: 1" = 20' DATE: JANUARY 27, 2005 r \_ SEWER LINES MUST BE SLEEVED FOR 10' EITHER SIDE OF CROSSING WITH WATERLINE OdA1A � �+ _' H . GALA w _ ND 0 '9.2 ' RE-ROUTE GASLINE Iv / QY N r 'L / !rCL ARNE H. OJALA, 0,/ P.E., P.L.S. DATE r ' R E�PROP. RESERVE AREA (450 SF) Err *SHOULD PRIMARY SYSTEM FAIL, REPLACE IN KIND, AND REMOVE AND REPLACE ANY CONTAMINATED SOILS LjY � r r � Ur \ f BENCHMARK: USE C. BASIN AT ELEVATION 25.0' H33G3311R3 mmr 19+V r-MMUCL3 LO OC LJ ZONING DISTRICT: R 40 YARD SETBACKS: FRONT = 30' SIDE = 20' REAR = 20' PLAN REF. - LCP 34907 A FLOOD ZONE: C GROUNDWATER FOUND AT EL. 14.9' ADJ: 1.8' (SDW 252, ZONE A) USE ADJ. WATER AT EL. 16.7' NOTES: 1. DATUM IS ASSUMED 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRivR TO COMMENCEMENT OF WORK. 11. WETLAND FLAGGED BY HAMLYN CONSULTING 12. ROOF RUN OFF TO BE DIRECTED TO DRYWELLS OR STONE TRENCHES TITLE 5 SITE PLAN OF 147 CENTER STREET IN THE TOWN OF: YARMOUTH (PORT) PREPARED FOR: RONALD & DEBORAH TRACHTENBERG 20 0 20 40 60 SCALE: 1" = 20' DATE: JANUARY 27, 2005 5' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF LEACHING FACILITY, DOWN TO SUITABLE SOIL LAYER. REPLACE WITH CLEAN MED. SAND. ENGINEER TO INSPECT AND CERTIFY REMOVAL off 506-362-4541 fox 508 362-9860 down, cape engineering, inc. CIVIL ENGINEERS LAND SURVEYORS 939 main st. yarmouth, ma 02675 r \_ SEWER LINES MUST BE SLEEVED FOR 10' EITHER SIDE OF CROSSING WITH WATERLINE OdA1A � �+ _' H . GALA w _ ND 0 '9.2 ' N0.2 '$o QY 'L / !rCL ARNE H. OJALA, 0,/ P.E., P.L.S. DATE 5' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF LEACHING FACILITY, DOWN TO SUITABLE SOIL LAYER. REPLACE WITH CLEAN MED. SAND. ENGINEER TO INSPECT AND CERTIFY REMOVAL off 506-362-4541 fox 508 362-9860 down, cape engineering, inc. CIVIL ENGINEERS LAND SURVEYORS 939 main st. yarmouth, ma 02675