Loading...
HomeMy WebLinkAbout83-1722.. - a �. BW 6 ' \ W01- ILL BVw S'� arw ! �GE BW 3 84 2 yOVAL K TO BEYAYTO- �BLOLX/FLAGSTONE - SET IN 4AND_-- -_.--- _ SHOWER LOT --f8 - g PA'/o PRO OSE \i 19-;303± S.F. BM.CORNER STE 0` O POOL ' EL 98.70 PROPOSED POOL FENCE o I -IN£ � --- 09 " PROPOdo CONSERVATION NO TES : P/ poOL ILTFR + -Po pS� - _ - _ - AND UMP . FROA, rL, 0 �p� 010 I. THE WORK LIM1T SHOWN SHALL BE FITTED WITH A SILT �--�; 1Q / FENCE AS REQUIRED BY THE CONSERVATION COMMISSION. 1 OAK TREES �` c9 4 / THE FENCED WORK LIMIT SHALL CONSIST OF A CONTINUOUS. STAKED, DUO -IN FABRIC SILT FENCE. THE FENCE SHALL - ✓s- CESSPOOL G o _ REMAIN IN PLACE UNTIL THE DISTURBED GROUND IS �a `\ STABILIZED COMPLETELY. PROVIDE ALTERNATE SILT FENCE : y o 1500 dL f p� SUCH AS STAKED HAYBALES IF NEEDED AS DIRECTED BY THE c� o s 9R.4' \ �- 1/SEPTTL`TANK ` 1� p� /moi �°y CONSERVATION COMMISSION. co \ Rp�Eo 1 0 2. NO CONSTRUCTION RELATED ACTIVITY SHALL OCCUR ON THE t WETLAND SIDE OF THE WORK LIMIT. sox J. INITIAL SOIL STABILIZATION WITHIN THE WORK LIMIT 'yam i� a SHALL BE ACCOMPLISHED BY APPLICATION OF MULCH AND/OR G �!� LOAM AND SEED WEATHER PERMITTING. r � - 4. FOR DETAILED SITE RESTORATIVE LANDSCAPING, PLEASE TP, , SEE ADDITIONAL SITE LANDSCAPING PLANS, A HIGH CAPACITY INFILTRATOR CHAMBERS 5. REFER TO ANY ORDER OF CONDITIONS ISSUED FOR THE 8M. PKNAIL M/tSTONE AROUND PERFORMED WORK ACTIVITY BY THE YARMOUTH CONSERVATION FL -100.00 0 COMMISSION. LEGEND LOCUS MAP C C8 CONCRETE BOUND —W— WATER LINE O HYDRANT —G— GAS LINE -- OHW— OVER HEAD WIRES # LIGHT POST —E— UNDERGROUND ELECTRIC LINE —T— UNDERGROUND TELEPHONE LINE — CTV— UNDERGROUND CABLEVISION LINE x-40.4 SPOT ELEVATION x-40-- EXISTING CONTOUR 40 PROPOSED CONTOUR DESIGN CRITERIA: GENERAL NOTES: DESIGN FLOW: 3 BEDROOMS AT 1/0 G.P.D. PER I. THIS PLAN 7S FOR THE DESIGN AND CONSTRUCTION BEDROOM EQUALS 330 G.P.D. OF THE SEWAGE DISPOSAL SYSTEM AND PERMITTING PURPOSES ONLY. NO GARBAGE GRINDER 2. VERTICAL DATUM IS ASSUMED. FOR BENCH MARKS SEPTIC TANK REQUIRED: SET. SEE SITE PLAN. 330 G.P.D. X 200x - 660 GAL. SEPTIC TANK PROVIDED: 1500 GAL. MIN. J. ALL CONSTRUCTION METHODS AND MATERIALS AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL SOIL ABSORPTION SYSTEM REQUIRED: CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL DESIGN PERC RATE ( 5 M1N/INCH BOARD OF HEALTH REGULATIONS. SOIL TEXTURAL CLASS - I EFFLUENT LOADING RATE - 0.74 GPD/SF 4, ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER 330 GPD / 0.74 GPD/SF - 446 S.F. REQUIRED AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH - PROVIDED: 4 HIGH CAPACITY INFILTRATOR STANDING H-20 WHEEL LOADS. CHAMBERS W/3.5'= STONE AROUND. A-460 S.F. 460 S.F. x 0.74 - 340 GPD 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 OR APPROVED EQUAL. SOIL TES T PIT DA TA & 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE AND WATERTIGHT. D -BOX SHALL INDICATES 17 INDICATES PERCOLATION — OBSERVED BE WATER TESTED FOR LEVEL WHEN THERE IS MORE `. LEST GROUNDWATER THAN ONE OUTLET. TP #1 7. BEFORE CONSTRUCTION CALL 'DIG -SAFE', 1-888-DI6-SAFE AND THE LOCAL WATER DEPT. 0' HORIZON TEXTURE COLOR 100.9 FOR LOCATION OF UNDERGROUND UTILITIES. A LOAMY IOYR SAND 3/3 8, EXISTING CESSPOOLS TO BE PUMPED DRY. REMOVED 10 ...................................... 100.1 IF IN THE AREA OF THE NEW SYSTEM AND LOAMY IOYR B BACKFILLED WITH CLEAN SAND. SAND 5/8 ..-------- . .. .... ............ 32' "••'•' 98.2 MEDIUM IOYR 9. NO DETERMINATION HAS BEEN MADE AS TO C SAND 6/8 COMPLIANCE WITH DEED RESTRICTIONS OR ZONING REGULATIONS. IT SHALL REMAIN THE CLIENTS RESPONSIBILITY TO OBTAIN ALL PERMITS. SPECIAL PERMITS. VARIANCES ETC, FOR THIS PROJECT. 54" NO WATER 144' 88.9 / r, y DATE: SEPTEMBER 30. 2004 TEST BY: STEPHEN HAAS WITNESSED BY: AMY VONHONE r PERC RATE: l 2 MIN/INCH f VARIANCES REQUIRED: TITLE 5. MAXIMUM FEASIBLE COMPLIANCE SECTION 15.211:111 MINIMUM SETBACK DISTANCES 10' IS REOUIRED BETWEEN THE SAS AND THE PROPERTY LINE. 5. 1S PROVIDED. A 5' VARIANCE IS REOUESTED.