Loading...
HomeMy WebLinkAboutEngineered Plan - 2016.5' SYSTEM PROFILE (NOT TO SCALE) PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 2" PEASTONE OR GEOTEXTILE FILTER FABRIC OVER STONE 25.5' MINIMIIAA 7r !1F ('OVFP OVFP PPP* ACT PRECAST H-10 RISERS (TY P.> 24.14 U 10" **EXISTING 14" TEE TEE SEPTIC TANK GAS BAF FOUNDATION— EXIST SEPTIC TANK — *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEND- ALL EGEND 99— EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. —[99]-- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH 1 TEST HOLE 2z; SLOPE OF GROUND C-QD UTILITY POLE \ 0 rn VY FIRE HYDRANT 0)' NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. CONCRETE COVERS TO WITHIN 3" GRADE 2% SLOPE REQUIRED OVER SYSTEM 25.0' NOTE: 2" MIN. WALL BLOCKS OR THICKNESS REQUIRED PRECAST RISERS 4"ASCH40 PVC MORTAR ALL H-10 6" MIN. SUMP PIPES LEVEL 1ST 2' COMPONENTS 12" MIN. INT. DIM. �ENDS (TMP)INV'S 171 919 SIDES 22.03' O O O O ) 0 0 0 0 ®®®® .. ...I�I��I� OC�O� �7C�OC� ) 0 0 0 0 22 74' o 0 0 0 0 0 0 0 0 )0°0°0000 * WATERTEST O'BOX oa�oa®oao�r� ®®ate®aa®oao ;Oo0o0o00 0 0 0 0 0 0 0 0 0 �oaooao��®® oaa00000000 ;0°0°0°0011 0 0 0 0 o 0 0) 0 0 0 0 �_° FOR LEVELNESS >°o°o°o°o as®000a000❑ ��l]0���0��® :0000°O°O ° °^° °_ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o O o 0 ' 21.30' 0000°°°° °0°0 19.2 21.47 °°°° LH -10 500 GAL. LEACHING CHAMBER BY ACME PRECAST OR EQUAL. 3/4"-1-1/2" DOUBLE WASHED STONE 4' MIN. (3) UNITS REQUIRED ALL AROUND PRECAST STRUCTURES 6" CRUSHED STONE OR MECHANICAL OVERALL DIMENSIONS TO OUTSIDE OF STONE: 33.50' X 12.83' COMPACTION. (15.221 [2]) i ( 2 % SLOPE) (1 % SLOPE) LEACHING 13.0' BOTTOM TH-1 64' D' BOX 12' FACILITY NO GROUNDWATER FOUND **INSTALLER SHALL CONFIRM MINIMUM SEPTIC TANK SIZE AT 1000 GALLONS AND ITS SUITABILITY FOR RE -USE. REPLACE WITH 1500 GALLON H-10 SEPTIC TANK IF NOT SUITABLE (OR H-20 SEPTIC TANK IF IT WILL BE SUBJECT TO VEHICLE LOADING). 7 TEST HOLE LOGS W W W W ENGINEER: CRAIG J. FERRARI, SE #13871 GRAVEL/ DIRT PARKING WITNESS: AMY VON HONE, RS �+ DATE: 6/30/2016 BENCHMARK: PERC. RATE _ < 2 MIN/INCH, GARAGE SILL ELEV. = 26.44 CLASS I SOILS 4 ELEV. �� 25' � 25 A O ➢ LS �' � 10YR 4/1 N TH 1 9" o O B LS 10YR 4/6 ' 15„ 237 25 � p�, p PERC C MS 1OYR 7/8 144” I I 13' NO GROUNDWATER ENCOUNTERED DCE # 12-122 FIRST FLOOR PLAN NOT TO SCALE 89.74' PAVED DRIVE — W_ GARAGE M N O SHED 160 71' X24 SECOND FLOOR PLAN NOT TO SCALE DATE NOTES 1. DATUM IS ASSUMED 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. Oland Fzd ck is gv a 0 D T' andy J l 0 ° Locus Route P � 0z n 9N LOCUS MAP NOT TO SCALE ASSESSORS MAP 39 PARCEL 35 SYSTEM DESIGN: 9 GARBAGE DISPOSER IS NOT ALLOWED 9.8oa EXISTING 3 BEDROOM DWELLING DESIGN FLOW: 4 BEDROOMS @ 110 GPD = 440 GPD USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2) = 880 **RE -USE EXISTING 1000 GAL. SEPTIC TANK LEACHING: SIDES: 2(33.5 + 12.83) 2 (.74) = 137 GPD BOTTOM 33.5 x 12.83 (.74) = 318 GPD TOTAL: 615 S. F. 455 GPD USE (3) 500 GAL. LEACHING CHAMBERS,(ACME OR EQUAL) WITH 4' STONE ALL AROUND APPROVED MA DATE BOARD OF HEALTH TITLE 5 SITE PLAN OF #72 HIGGINS CROWELL ROAD WEST YARMOUTH, MA PREPARED FOR JACK LYONS �'arr3lOUth Health Delpartimert M??�/VED Pa>It¢ Date ��Fss�oSTEr \a_ 0S` U DANIEL A. OJALA, P. E., P.L.S. DATE: JULY 14, 2016 Scale: 1"= 20' 0 10 20 30 40 50 FEET off 508-362-4541 I fax 508-362-9880 downcope.com @ d0Wn ca►tOe eftineefin8, i11c. civil engineers land surveyors 939 Main Stree t ( Rte 6A) YARMOUTHPORT MA 02675 12-122