HomeMy WebLinkAboutEngineered Plan - 2016ACCESS COVERS MUST BE WITHIN 9" MINIMUM. 6" OF FINISH GRADE 3' MAXIMUM COVER FIRST 2' TO BE LEVEL MIN 2 " OF PEA STONE OR F I L TER FABRIC V OIAM PIPE 96.6 3/4" - I 1/2" DIA. 97.5 96.3 12" H-20 %° DOUBLE WASHED STONE GAS BAFFLE 96.47 �� p 96.2 °t7 95.2 3 OUTLET 4 LC -6 LEACHING CHAMBERS EXISTING D -BOX W/3' STONE SIDES, 4' ENDS. 9'w x 40'1 x 12"d 1000 GAL H-20 SEPTIC TANK 6" CRUSHED STONE OR COMPACTED BASE NPROFILE : NOT TO SCALE LOCUS MAP INVERT EL E VA T I ONS : INVERT OUT SEPTIC TANK: 97.5 INVERT IN DIST. BOX: 96.47 INVERT OUT DIST. BOX: 96.3 INVERT IN LEACH CHAMBER: 96.2 BOTTOM OF LEACH CHAMBER: 95.2 ADJUSTED GROUND WATER: N/A OBSERVED GROUND WATER: N/A BOTTOM OF TEST HOLE #1: 88.8 DESIGN CRITERIA DESIGN FLOW: 3 BEDROOMS AT 110 G.P.D. PER BEDROOM EQUALS 330 G.P.D. NO GARBAGE GRINDER SEPTIC TANK REQUIRED: 330 G.P.D. X 2009 - 660 GAL. SEPTIC TANK PROVIDED: 1000 GAL. EXISTING SOIL ABSORPTION SYSTEM REQUIRED: DESIGN PERC RATE C 5 M I N/ I NCH SOIL TEXTURAL CLASS - 1 EFFLUENT LOADING RATE - 0.74 GPD/SF 330 GPD / 0.74 GPD/SF - 446 S.F. REQUIRED PROVIDED: 4 LC -6 LEACHING CHAMBERS W/3' STONE SIDES. 4' ENDS. A-458 S.F. 458 S.F. x 0.74 - 339 G.P.D. SOIL TEST PIT DATA& INDICATES V INDICATES GENERAL NO TES : I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION OF THE SEWAGE DISPOSAL SYSTEM ONLY. 2. VERTICAL DATUM IS ASSUMED. FOR BENCH MARKS SET. SEE SI TE PLAN. J. ALL CONSTRUCTION METHODS AND MA TER I AL S AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULA T I ONS . 4. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3 ' I N DEPTH SHALL BE CAPABLE OF WI TH- STANDING H-20 WHEEL LOADS. 5. ALL SEWER PIPE SHALL BE SCHEDULE 40 PVC OR APPROVED EQUAL. 6. SEPTIC TANK AND D -BOX SHALL BE REINFORCED PRECAST CONCRETE OR APPROVED POLYETHYLENE. i PERCOLATION = OBSERVED BOTH SHALL BE WATERTIGHT. D -BOX SHALL BE WATER TEST = GROUNDWATER TESTED FOR LEVEL WHEN THERE IS MORE THAN ONE StpG�Pp TP *1 OUTLET. 0 HORIZON TEXTURE COLOR 99.0 /LOAMY IOYR 7. BEFORE CONSTRUCTION CALL 'DIG -SAFE'. -A _ L 0 T 279, A SAND 314 1 -888 -DIG -SAFE AND THE LOCAL WATER DEPT. °Zha 10.299+ S F !0' - - - - - - - - - - - - - -- 98.2 FOR LOCATION OF UNDERGROUND UTILITIES. y 92 Z II Gp1\0 B SANDY 516R BY. CORNER PATIO �P_ _ _ - _ - - - - - - _ _ 97.2 8. EXISTING LEACH PIT TO BE PUMPED DRY AND I EL -100.7 I \t 6, 22 " MEDIUM IOYR \�� o Cl SAND 714 BACKF l L LED . oy EXISTING 2c 9. EXISTING SEPTIC TANK TO BE PUMPED AND CLEANED. / y y SEPT/C TANK � EXISTING PIT 48' INSPECT AND REPLACE INLET TEE IF REQUIRED. UNDER GRAPE 99 5 ARBOR +i00\6 \ \ R\`l� 1y o / V \\ G 6 Fy \\ O I 95.9 122. NO NATER Be. 8 \�` ` DATE: JUNE 16. 2016 �pplA gP�� \\ TP*1 I TEST BY: STEPHEN HAAS \ G - WITNESSED BY: AMY VONHONE RpO� / 4 LC6 PRECAST CHAMBERS PERC RATE: C 2 MIN/INCH e�0 99 8 W//_1' STONE SIDES. 4' ENDS !� l 0���pp 98.5 98.6 / VARIANCES REQUI RED : TITLE 5. MAXIMUM FEASIBLE COMPLIANCE 0199.8 \ \ c \ Qp z ,C�pOE eP `\ 98.3 SAO SECTION 15.211:(1) MINIMUM SETBACK DISTANCES + 20' IS REQUIRED BETWEEN THE SAS AND THE FOUNDATION, 14' IS PROVIDED. -Box � 95 3 A 6' VARIANCE IS REQUESTED. o ` --- - 9G \ \ \ 9-). sA1tiA a �` S 9 i\ OF M gat 98.7 E�� r A \ \ Mcg SS r ` JOHN nth Health De rnemtZ. \ a - DEMAREST,JR. N '1 9G \ \ \ O --- \ 9 \ ` , 95.5 \ UP 0 10 20 40 -o o. 36859 s � k � ,.-. ? � ate-• Permit valid for REPAIR CT SEPTIC S4 ST1',R ONLY; dice to State .and I,ucal septic variance_ 7.,, ,,, rig_°'" , ate Board of Ilealth review and a�)proval is required fu any future additions/ecnurntions/alterations to sewage facilities and/or structm-esAINNelhng. Yarmouth Health Department: �sSEP T / C S YS TEM DES l GN l 74 FOREST ROAD . MAP 58 PARCEL 251 am c bake, SOUTH YARMOUTH. MA. \ PREPARED FOR: LEGEND SA I D ,A L H A R T H Y 93 CB CONCRETE BOUND -W WATER LINE SCALE: / s 20 JUL_ Y 2 / 20 / 6 O HYDRANT -G GAS LINE STEPHEN A. HAAS OHW- OVER HEAD WIRES _4F LIGHT POSTENGINEERING, INC � UNDERGROUND ELECTRIC LINE , / r P . O . B o x 16 -T- UNDERGROUND TELEPHONE L INE jam j/ ��� �I i/�� South D e n n i s MA 02660 -CTV- UNDERGROUND CABLEVISION LINE �-�� '1 �� \� 508 362-8132 +40.4 SPOT ELEVATION ,_40 ----- EXISTING CONTOUR W-0-1 PROPOSED CONTOUR JOB NO: 16-035 1