HomeMy WebLinkAboutEngineered Plan - Rev. 2016TOP FOUND. EL. 17.6' 15.6'±* - ACCESS COVER AT FIN. GRADE EL. 17.0 SYSTEM PROFILE (NOT TO SCALE) PROVIDE MIN. 20" DIAM. WATERTIGHT ACCESS COVER TO WITHIN 6" OF FIN. GRADE MINIMUM 1' OF COVER I MINIMUM 75' OF COVER OVER POLY TANK I OVER PRECAST ' PROPOSED 1,500 GALLON POLYETHYLENE SEPTIC TANK (H-10) EL. 16.0 4"OSCH40 PVC 16.1"(1.34') PIPES LEVEL 1ST 2' 14.66' GAS BAFFLE 000000000o WATERTEST D'BOX0Oo RaLEVELNESS S ° 14.56' 14.39' 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [2]) NOTE: 2" MIN. WALL DEPTH OF FLOW = 4' THICKNESS REQUIRED REQUIRED TEE SIZES: INLET DEPTH = 10" MIN. BELOW FLOW LINE OUTLET DEPTH = 14" MIN. BELOW THE FLOW LINE NOTE: STANDARD TEES ARE TO BE USED. DO NOT USE MANUFACTURER'S TEES THAT COME WITH THE TANK ( 3.6% SLOPE) (-L% SLOPE) FOUNDATION- 19' SEPTIC TANK 10' D' BOX *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM LEGEN D _99- EXISTING CONTOUR X 99 1 EXIST. SPOT ELEV. -[991- PROPOSED CONTOUR 198•41 PROPOSED SPOT EL. TH 1 "``'Z-/- TEST HOLE LOCUS SLOPE OF GROUND M-) UTILITY POLE FIRE HYDRANT NOTE NOT ALL SYMBOLS MAY APPEAR IN DRAWING TEST HOLE LOGS ENGINEER: CRAIG J. FERRARI, SE #13871 WITNESS: AMY VON HONE, RS DATE: 7/20/16 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS ELEV. 0„ `V 16.6' 8" 1911 PERC N S 1OYR 4/2 B LS 1OYR 5/8 C FS 1OYR 7/6 15.0' 132" I 15.6' NO GROUNDWATER ENCOUNTERED INCE # 16-221 (_1_% SLOPE) d ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. 2% SLOPE REQUIRED OVER SYSTEM 17.0' PROVIDE INSPECTION PORTS TO un,ruiki z" nr C MISH GRADE 16 H-20 HIGH CAPACITY INFILTRATORS EACH UNIT: 6.25' X 2.83 X 16" HIGH OVERALL DIMENSIONS TO OUTSIDE OF UNITS: 25' X 11.3' (NO STONE PROPOSED) LEACHING FAC I LITY NOTES 1. DATUM IS NAVD 88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40=4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND 7.83' VERIFYING THE LOCATION OF ALL UNDERGROUND & LOCUS MAP OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. NOT TO SCALE 5.6' BOTTOM TH-1 NO GROUNDWATER FOUND 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE ASSESSORS MAP 49 PARCEL 57 PROPOSED LEACHING FACILITY. SITE IS NOT LOCATED WITHIN A ZONE II 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED. VARIANCE REQUESTED: UNDER MAX. FEASIBLE COMPLIANCE 15.405: (1b): REDUCTION IN SETBACK, SAS TO FOUNDATION (20' TO 15.8') Scale:1 "= 20' 0 10 20 30 40 50 FEET FAMILY ROOM I BEDROOM KITCHEN BEDROOM BATH BEDROOM EXISTING FLOOR PLANS NOT TO SCALE Permit valid for REPAIR OF SE1111(' SVS'I*M ONLY, (lite to State and Local septic variances. Board of Health review and approval is required for any future additions/rennv:+tions/alterations to sewage facilities an /or struetu.res/d«elling. Yarmouth 11calth iiepartment APPROVED 4 4N&e: bate 6_15-k, DATE DANIEL A. OJALA, P.E., P.L.S. SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL. H-10 POLY SEPTIC TANK LEACHING: 4.73 SF/LF x 6.25' LENGTH = 29.56 SF PER HIGH CAPACITY INFILTRATOR UNIT __330 GPD/0.74 GPD/SF = 445.9 SIT LEACHIN_G____ _ REQ'D 445.9 SF/29.56 SF/UNIT = 15.1 UNITS THEREFORE, USE GRAVELLESS SYSTEM OF (16) H-20 HIGH CAPACITY UNITS IN FIELD CONFIGURATION OF 4 ROWS OF 4 UNITS 16 UNITS x 29.5 SF = 472 SF > 445.9 SF 472 SF (0.74) = 349 GPD (OK) APPROVED 4 MA IDATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 21 CIRCUIT ROAD EAST WEST YARMOUTH, MA PREPARED FOR CAPE COD SEPTIC/ CONSTITUTION DATE: JULY 27, 2016 REV: AUGUST 8, 2016 (PLASTIC) REV: AUGUST 15, 2016 (3 BEDROOM) off 508-362-4541 fax 508-362-9880 I downcope.com down c41pe e#7 ineefing, inc. civil engineers land surveyors. 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 16-221 CC SEPTIC-CONSTI TUTION.DWG 0 00 10v+ T �N LOCUS o c e S�e� `off o� ,S ote 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND 7.83' VERIFYING THE LOCATION OF ALL UNDERGROUND & LOCUS MAP OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. NOT TO SCALE 5.6' BOTTOM TH-1 NO GROUNDWATER FOUND 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE ASSESSORS MAP 49 PARCEL 57 PROPOSED LEACHING FACILITY. SITE IS NOT LOCATED WITHIN A ZONE II 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED. VARIANCE REQUESTED: UNDER MAX. FEASIBLE COMPLIANCE 15.405: (1b): REDUCTION IN SETBACK, SAS TO FOUNDATION (20' TO 15.8') Scale:1 "= 20' 0 10 20 30 40 50 FEET FAMILY ROOM I BEDROOM KITCHEN BEDROOM BATH BEDROOM EXISTING FLOOR PLANS NOT TO SCALE Permit valid for REPAIR OF SE1111(' SVS'I*M ONLY, (lite to State and Local septic variances. Board of Health review and approval is required for any future additions/rennv:+tions/alterations to sewage facilities an /or struetu.res/d«elling. Yarmouth 11calth iiepartment APPROVED 4 4N&e: bate 6_15-k, DATE DANIEL A. OJALA, P.E., P.L.S. SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS @ 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 USE A 1500 GAL. H-10 POLY SEPTIC TANK LEACHING: 4.73 SF/LF x 6.25' LENGTH = 29.56 SF PER HIGH CAPACITY INFILTRATOR UNIT __330 GPD/0.74 GPD/SF = 445.9 SIT LEACHIN_G____ _ REQ'D 445.9 SF/29.56 SF/UNIT = 15.1 UNITS THEREFORE, USE GRAVELLESS SYSTEM OF (16) H-20 HIGH CAPACITY UNITS IN FIELD CONFIGURATION OF 4 ROWS OF 4 UNITS 16 UNITS x 29.5 SF = 472 SF > 445.9 SF 472 SF (0.74) = 349 GPD (OK) APPROVED 4 MA IDATE BOARD OF HEALTH TITLE 5 SITE PLAN OF 21 CIRCUIT ROAD EAST WEST YARMOUTH, MA PREPARED FOR CAPE COD SEPTIC/ CONSTITUTION DATE: JULY 27, 2016 REV: AUGUST 8, 2016 (PLASTIC) REV: AUGUST 15, 2016 (3 BEDROOM) off 508-362-4541 fax 508-362-9880 I downcope.com down c41pe e#7 ineefing, inc. civil engineers land surveyors. 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 16-221 CC SEPTIC-CONSTI TUTION.DWG