Loading...
HomeMy WebLinkAbout83-1737 - Site Plan002FIRST FLOOR EL. 12.3' SYSTEM PROFILE TOP FNDN EL. 11.4'NOT To SCALE) ACCESS COVER TO WITHIN 6" OF FIN. GRADE ( ACCESS COVER (WATERTIGHT) TO /�' WITHIN 6" OF FIN. GRADE '1,Q' MINIMUM .75'.OF COVER OVER PRECAST { 2% SLOPE REQUIRED OVER SYSTEM RUN PIPE LEVEL 2' DOUBLE WASHED PEASTONE. 9.05' FOR FIRST 2' PROPOSED 1500_ GALLON SEPTIC 8.85, 8.60 TANK (H- 10 ) GAS g•01' BAFFLE 000 7.98' o (-2-% SLOPE) t6' CRUSHED STONE OR MECHANICAL - _ So. COMPACTION. (15.221 (23)�b DEPTH OF FLOW = , 4, (.-!- ". R SLOPE) (-i-% % SLOPE) TEE SIZES: 3/4" TO 1 1/2" DOUBLE WASHED STONE INLET .DEPTH .e:1.0" OUTLET DEPTH 14" TEST HOLE LOGS ENGINEER: LISA LYONS, RS 11 WITNESS: SUE RASK, RS DATE: 6/15/05 0.75' MIN. PERC. RATE _ < 2 MIN/INCH 8 4' CLASS I SOILS PERCOLATION TESTING PERFORMED 8/31/05 BY RICK JUDD. RS, AMY VON HONE, RS WITNESSING.. RATE: < 2 MIN/INCH IN LS SAND LAYER oELEV. 7.4 0„/ 55-8, 0,. Q 5.7' FOUNDATION- .10' - SEPTIC TANK 42' D' BOX 5' LEACHING FACILITY USE GROUNDWATER EL. 2.4' (TIDALLY INFLUENCED) TOP ELEV VARIES40 Ma POLY VINYL AND 11.4' TO 8.4' 1. 0. MASTIC ON INSIDE OF NOTE MONITORING WELLS WERE SET ON LOTS 2 AND 3, AND HIGHEST RE AINING WALL. READING USED OVER NEW MOON TIDAL CYCLE DURING WET TIME OF YEAR (APRIL 2003) i A, (6) M3 BARS CONT. FOR HORIZONTAL REINFORCEMENT PROP. CONC RET. WALL .. 7,4' TO 4.4 EL 8.4' ' F1 6.0' LOWEST PROP ELEV. (FINAL GRADE) SHOWING VARYING ELEVATIONS E /3 BARS 12' O.C. FOR VERTICAL EL. 8.4' •�. REINFORCEMENT EL 11.4' EL. 11.0' r PR BASE ELL OP SAS 9° A EL, 11.0' NATURAL SOIL EL. 8.4' 1 BASIN ELEV. = 6A RVE &6 SF Il ® 6, SMALL AREA a)I DRAIN n m 6.3 - �y +63 _ x (urL,ANU) ., - PROP. WUKK UMII ! ,.. \►► l- . CONC. RET. WALL (NTS) PROP. HOUSE EL 10.0' LINE ( ILT FENCE) y . •ir.l ,. I 7.1 +. 4,7 ' 511 417 \ -moi + 3 RUN JJ \ +7, A % PROP, CONCRETE RET. WALL AROUND SAS +6.6 0 113.641 TH2 THH11 (SEE DETAIL) Z ENGINEER SHALL STAKE FOOTING PRIOR TO POURING cfl w O 0 n .2981 w 7.0' tee' 9.2' 0 / 1 +4.6 I CATCH „i BENCHMARK - CTR. OF 1 BASIN ELEV. = 6A RVE &6 SF Il ® 6, SMALL AREA a)I DRAIN n m 6.3 - �y +63 _ x (urL,ANU) ., - PROP. WUKK UMII ! ,.. \►► - LINE ( ILT FENCE) y . •ir.l ,. I N +. 4,7 ' 417 \ -moi RUN JJ \ k.. TO NE 4.1 1, ENGINEER SHALL INSPECT WHEN REWIRED EXCAVATION IS COMPLETE y _ + 5.1 " Z ENGINEER SHALL STAKE FOOTING PRIOR TO POURING cfl O +5.5 �. OF WALL -4. ENGINEER SHALL�INSPECT WHEN CLEAN FILL HAS BEEN PROPERLY SO 1 +4.6 I „i h +65 4 a.0 LOT'2 N ' \ .9 REQUIRED INSPECTIONS AND CERTIFICATIONS k.. 2.6 +5.7 1, ENGINEER SHALL INSPECT WHEN REWIRED EXCAVATION IS COMPLETE _ Z ENGINEER SHALL STAKE FOOTING PRIOR TO POURING 3. ENGINEER SHALL INSPECT FOOTING AND REBAR PRIOR TO POURING + 5.3 OF WALL -4. ENGINEER SHALL�INSPECT WHEN CLEAN FILL HAS BEEN PROPERLY DEPOSITED 5, ENGINEER SHALL AND CERTIFY SEP TIC COMPONENTS AND PUMP MECHANISMSS AFTER AFTER INSTALLATION ]G ENGINEER SHALL CERTIFY TO YARMOUTH HEALTH DEPARTMENT THAT ' THE RETAINING WALL. SEPTIC SYSTEM AND PUMP MECHANISMS HAVE n �:+ 4.1 I BEEN INSTALLED IN SUBSTANTIAL COMPUANCE WITH THE APPROVED PLAN. FILL 9' 39" 44" 120" A/E LS 1OYR 5/1 e LS 1 OYR 4/3 2.55' C MOTTLES O 41• IVIS (EL 2.38') 1OYR 5/4 1 A/E MS IOYR 3/1 B LS 10YR 4/3 40" 2.36' MS 42" obs. water. 2.2' 2.5Y 5/3 -4_2 120" SEPTIC DESIGN: (GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS (1110GPD) = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (4a) = 1485 USE A 1500 GALLON SEPTIC TANK LEACHING: SIDES: 2--� (3,74 25 + 10.83)_(.74) (.58) = 41.2 ------ BOTTOM: 37.25 x 10.83 (.74) = 298.5 TOTAL: 459 S.F. 339.7 GPD JSE 5 STANDARD INFILTRATORS WITH 4' STONE AT SIDES AND 3' AT ENDS LEGEND 100.0 PROPOSED SPOT ELEVATION 100x0 EXISTING SPOT ELEVATION 100 PROPOSED CONTOUR - 100- EXISTING CONTOUR APPRDVED DATE off 508-362-4541 fax 508 362-9880 down cape engineering, inc. CIVIL ENGINEERS LAND SURVEYORS 939 slain St. yarmouth, ma 02675 -4.3' BASS RIVER PARKWAY I RIVER ST. CRESCENT CT. N LOCUS / L LOCATION MAP NOT TO SCALE ASSESSORS MAP 34 PARCEL 266 ZONING DISTRICT: RS 40 YARD SETBACKS: FRONT = 30' SIDE = 20' REAR = 20' PLAN REF. - 198/111 FLOOD ZONE: All EL. 11 NOTE: FLOODZONE FOUNDATION REQUIRED (DESIGN BY OTHERS) NO LIVING SPACE, UTILITIES DUCT WORK, AIR CONDITIONING, ETC. ALLOWED BELOW ELEV. 11.0' FINAL GRADING TO BE IN CONFORMANCE WITH FEMA FLOODZONE REGULATIONS NOTES: 1. DATUM IS NGVD 2. VUNICIPAL WATLER IS AVAILABLE 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PRECAST UNITS TO BE AASHO H- 10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH MASS. ENVIRONMENTAL CODE TITLE V. 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. TITLE 5 SITE PLAN/ OF LOT 1 (#145) SOUTH STREET IN THE TOWN OF: (SOUTH) YARMOUTH PREPARED FOR: SIDDHARTH 30 0 30 •0 •• MA SCALE: 1" = 30' DATE: OCTOBER 4, 2005 �LSHOFL.4 SA OF ^oar ARNE H oy ARNE o OJALA H U r.N 0.33 0 9 t D 340 r AR ;L uav S. DATE