Loading...
HomeMy WebLinkAbout83-1737 - Site Plan004LEGEND 99- EXISTING CONTOUR X 9B.J EXIST. SPOT ELEV. - 9 PROPOSED CONTOUR F991 PROPOSED SPOT EL. TH1 o°A V W ow S/ m o TEST HOLE 7 SLOPE OF GROUND rQ) UTILITY POLE y91 FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM RUN POND (TI DAL) 09-276 I off 508-362-4541 fax 508-362-9880 downcope.com down cape engineefing, Inc. civil engineers land surveyors 939 Mcin Street ( Rte 6A) YARMOUTHPORT MA 02675 LEACH FIELD DETAIL 1"=20' SYSTEM DESIGN: GARBAGE DISPOSER IS NOT ALLOWED DESIGN FLOW: 3 BEDROOMS ® 110 GPD = 330 GPD USE A 330 GPD DESIGN FLOW SEPTIC TANK: 330 GPD (2) = 660 NO BASEMENT ALLOWED USE A 1500 GAL. SEPTIC TANK SEE NOTE CRAWLSPACE LEACHING: SIDES: N/A BOTTOM 30 x 15 (.74) = 333 GPD TOTAL: 450 S.F. 333 GPD USE 4" PERF. PVC PIPE AND STONE LEACH FIELD DIMENSIONS: 30' x 15' x 0.5 DEEP SEE DETAIL 29S't _ SYSTEM PROFILE (NOT TO SCALE) PROVIDE WATERTIGHT ACCESS COVERS TO WITHIN 6" OF FIN. GRADE PRECAST H-10 M1ve RISERS `111 .) 2'0 8.49' uTEE 1500 GAL SEPTIC TANK -10 TEE 4' U0. LEVEL GAS & ACME OR EOUAL OF rT 4"1tiSCH40 PVC PIPES LEVEL IST 2' 8 24 0 0°0°0°0°0°0 6" MIN. SUMP LE ° °g°g °g g° 7.95 ° o°o°^Oo°000° °c 8.15' " 7.98' 00C o0c nor 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [21) WATER TEST D'BOX FOR LEVELNESS ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. VENT WITH CHARCOAL FILTER 2% SLOPE REQUIRED OVER SYSTEM ( 9 SLOPE) (-L% 7 SLOPE) FOUNDATION= 18'- - SEPTIC TANK --- 9' - (__L_7 SLOPE) D' BOX 5' - FLOODZONE DESIGN FOUNDATION FOR DWELLING AND GARAGE REQUIRED (BY OTHERS) NOTE: FINAL GRADING TO BE IN ACCORDANCE WITH FEMA REQUIREMENTS NO BASEMENT ALLOWED. I.E. VENTED CRAWLSPACE TO HAVE SLAB AT OR ABOVE OUTSIDE GRADE, 1 SMARTVENT PER 200 SF CRAWLSPACE LOCATED WITHIN 12" OF GRADE 2 SIDES. 5' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF LEACHING FACILITY, DOWN TO SUITABLE SOIL LAYER. REPLACE WITH CLEAN MED. SAND, TO MEET SPECIFICATIONS OF 310 CMR 15.255(3) 40 MIL LINER TO BE PLACED ALONG REMOVAL LIMIT TOP AT EL. 8.5, BOTTOM AT EL. 4.5 PROVIDE STAKED SILT FENCE ALONG PROPERTY LINE PROVIDE INSPECTION PORT TO 2" DOUBLE -WASHED PEASTONFi� OR GEOTEXTILE FABRIC n ��/ \\\ 7.3' 4" PVC SET AT .005'/' SLOPE -j 6" DOUBLE WASHED 3/4" - 1 1/2" STONE 5.0' TIDALLY INFLUENCED GROUNDWATER ELEV. 2.3' MONITORING WELL SET AND AUTOMATED READINGS TAKEN OVER A FULL MOON CYCLE (HIGHEST TIDES OF THE MONTH) LEACHING FACILITY MONITORING WELL SET 7/18, AUTOMATED GROUNDWATER READINGS WERE TAKEN OVER THE FULL MOON CYCLE I 1 UTIL POLE S�^ vl 1 , y y SMALL AREA 1 DRAIN 1� 11 I BENCHMAR 1 1 BASIN ELE 1 II I I III LINE III III I`` SMALL V AREA DRAIN SPEED LIMIT SIGN I 1)UTIL POLE 6' l I I I I I 1 I DATE DANIEL A. OJALA, P.E., P.L.S. OF FINAL GRADE 40 MIL LINER 5' MIN. OFF LEACHING, TOP AT EL. 8.5, BOTTOM AT EL. 4.5 NOTES 1. DATUM IS NGVD29 2. MUNICIPAL WATER IS -AVAILABLE - - 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H -1Q 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE V.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. WETLAND FLAGGED BY HAMLYN CONSULTING. 13. ROOF RUN-OFF TO BE DIRECTED TO DRYWELLS, OR TO DRIP TRENCHES 11 N LOCUS MAP NOT TO SCALE �) ASSESSORS MAP 34 PARCEL 266 5 LOCUS IS CURRENTLY WITHIN FEMA o, Q\e ooD Q ON -COMMUNITY -PANEL -#250015-0006 M rn o°A V W ow S/ m o CONSULTING v g ZONING DISTRICT: RS -40 n R A MIN. LOT SIZE 40,000 SF* 0 a Locus a MIN. FRONT SETBACK 30' sh Nantucket 21,0' Sound Saurr LS LOCUS MAP NOT TO SCALE �) ASSESSORS MAP 34 PARCEL 266 Q LOCUS IS CURRENTLY WITHIN FEMA FLOOD ZONE A11 EL. 11 AS SHOWN ON -COMMUNITY -PANEL -#250015-0006 D- - JULY 2, 1992, SITE IS IN AN OPA, NO INS. WETLAND FLAGGED BY HAMLYN CONSULTING ZONING SUMMARY ZONING DISTRICT: RS -40 AI LS PROVIDED MIN. LOT SIZE 40,000 SF* 17,765 SF UPLAND MIN. LOT FRONTAGE 150'* 91.00' MIN. FRONT SETBACK 30' 49.5' MIN. SIDE SETBACK 20'(6'*) 21,0' MIN. REAR SETBACK 20' 268' *LOT CREATED 12/1/65 (GRANDFATHERED) SITE IS NOT LOCATED WITHIN MESA/NHESP MAPPING TEST HOLE LOGS ENGINEER: LISA LYONS, RS WITNESS: SUSAN RASK, RS DATE: 6/15/05 PERC. RATE _ < 2 MIN/INCH CLASS 1 SOILS PERCOLATION TESTING PERFORMED 8/31/05 BY RICK JUDD, RS, AMY VON HONE, RS WITNESSING; RATE IS < 2 MIN/INCH IN LS LAYER p" �) ELEV. 5_8' Q' Q ELEV. 5.7' FILL A/E 9" MS AI LS 18 1OYR 3/1 22" 1OYR 5/1 B B LS LS 1OYR 4/3 39" 1OYR 4/3 2.55' 40" Mom Es e 47• (EL 2.381 2.36' C MS C MS 44" obs. water 2.13' 42" obs. water 2.2' 1OYR 5/4 2.5Y 5/3 120" -4.2 120" -4.3' OF #145 SOUTH STREET SOUTH YARMOUTH PREPARED FOR DATE: JULY 31, 2013 REVISED: 8-7-2013 (GRADES, REMOVE RET. WALLS) Scele: 1"= 20' 0 .iD 20 30 40 50 FEET 09-276 MARTIN LAYOUT2.DWG V