HomeMy WebLinkAboutReview Checklist! ���-i-�
TOWN OF YARMOUTH �'�`���_-�
' , t �i -� � �
SEWAGE PLAN REVIEW CHECKLIST ���� � ���-�'�
. Location: A.M.� Lot �� Zone of Contribution: In ut_ Acreage�'����
� !_,,�/��/ Commercial: ResidentiaL•
Street: ���� '�
Village: Floor Plan: ��� #Bedrooms:�
�G ��o��: �S�ii�: �
' Address: Phone: c�
�
j Phone:
� ��� ��
Builder: Engineer:
' Address: Phone: �
Phone: Tl� - f� -�!���.2-/ � �
N/A YES O
1.Required#of copies received
2.Date of soils exam and ercolation test not older than 2 years -
3.4-5 ft of naturall occurrin ervious material, above water table
4.Foundation 2 ft above high oint of road H.P.: Fnd: Var.:
5.Water line 10 ft from s tic components Var.: �-�
6.Benchmark indica.ted and shown-NGVD if near wetlands ��
7. S tic tank minimum 10 ft from foundation, deck Var.: •
8.Lea.ching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9.Leachin minimum 100 ft from wetlands Var.:
10.Leaching minimum 150 ft from drinking welU25 ft irri tion well Var.: --�
11.Tank/leaching minimum 10 ft from pro erty line Var.: �;�''
12. S stem meets all other setback r irements Var.:
13.Uses adjustment for maximum hi oundwater Var.:
14.Leachi.ng set 4-5 ft above adj.water or bottom of test hole Var.:
15. S stem not in to or subsoil(A,B horizons)or 5'removal
16.Pro osed contours are suitable
17. S stem meets slo e r uirements-min. 1/8", '/4" eferred
18. System meets breakout re uirements PVC liner: Wall:
19. Spec�ed tee sizes are ro er, as baffle on outlet tee
20. Sewa e is under 10,000 d for parcel
, 21.No arbage dis osal �`"
22.S stem ad ua.tel sized for its intended use -
23.Minimum 6"stone or com acted below tank and dbox
• 24.Manhole covers within 6"of ade,pum chamber cover to ade
25.Inspection ort on lastic chambers/leach field
26.Electrical ermit for um cha.mber/S arate meter for du lexes -�
27.Pum system-2" line,wee hole,check valve,tee in dbox,pum size -�
28. Septic tank/ um chamber to be factory wat roofed /'
29.Vent rovided if leachin below 3 feet,under drivewa / arking /
30.Buoyancy calculations for tank/pump chamber ---�`
31.En ' eer to ins ect and cert' soils: wall: commercial:
32.Engineer/Re 'stered Sanitarian and Land Surveyor stam s/si ature `
33.H-20 loadin is subject to vehicular tr�c, oundwater
34.Title V A lication and ermit fee, installer si ature
35.Foundation footin min. 2 feet above adjusted ground water for new house �--''
36.Deed Restriction r uired max. #bedrooms: maar. flow: d �"""
37. Check area lots for oundwater/Label oundwater in Assessor's Ma
Plan reviewed by: �os�o3