Loading...
HomeMy WebLinkAbout83-1753 - Site & Sewage Plan0021 m BROADWAY LOCUS Q. oRF Ro T eeS TFR ST LOCUS MAP\ I #18 COLUMBUS AVENUE #14 COLUMBUS AVENUE NOT TO SCALE: I ASSESSORS MAP 22 I ASSESSORS MAP 22 PARCEL 443 PARCEL 442 ` I I D.T.H. #1 DATE: OCTOBER 19, 2005 GROUND ELEV 8.1 j NO GROUNDWATER CONCRETE BOUND 10.00' J I I 90.00' FOUND & HELD 1 FILL A o LOAMY SAND 10YR 3/2 B 1Do- 00, / MEDIUM SAND 7.5YR5/8 I _ I \ r r 1 1 SYSTEM PROFILE: 2.85 C , ` MEDIUM SAND 2.5Y 6/2 A. VON HONE \ \ � \ NOT TO SCALE FIRST FLOOR TOP OF FOUNDATION ° RAISE COVERS TO WITHIN 6" OF FINISH GRADE I \ RO OS PO L F NC \ 1 t1 0, ELEV. 12.5 INDICATES MICHAEL & JUDITH McKAY _ _ / i D. MEYER DRAINAGE DEPRESSION \\ \\ \ 9.2 L� ...�... ,... ...... 9 I o o P -1A 44" PERC TEST 64" INDICATES GROUNDWATER ;8 SHORE RD. - - - - - - ' ELEV. 13.5 BACKHOE OPERATOR. , (PER .YARMOUTH CONSERVATION OFFICER) / \ o ° \.............. �'O \ w 48" ' FINISH GRADE - / FINIS4RADE �' `_- - - 10x14' a SILVER LEAF LANE 52„ .• ELEV. 11.8 \ ELEV. w I FINISH GRADE BUILDING .12 PERC RATE: LOADING RATE: 0_74 GAL/SF/MIN /� ASSESSORS MAP 22 .�� ..... °.... ............ ... .ELEV. 11,0 GROUND ELEVATION 10.75 63" I 1 ° o /h T P = 11 •• \ /// /� , MIN. WELL MIW-29 , ----------- 64" 1 -3' MAX. COVER m "ENGLEWOOD" ° .' 10'0 2% SLOPE ?� FLOOD VENTS TO BE INSTALLED 4'® 1:5% SLOPE TOP STONE ELEV 9.92 �� 2" MIN 1/8"-1/4" DOUBLE WASHED PEA STONE / ° ;. ° c r. 4" PV PER ARCHITECTURAL PLANS 4" PVC SCH 40 O O OO O OO O 00 OO O O o ° SCH 40 INV.= 22 MIEN-3rMAX USE BOH ALLOWED ADJ. OF 1.0' OQOpOOpO�00pO�000pO00p0 INV.= 10.34 10.14 10"TEE 9.89 O O OOOO O 0 0 0 0 0 0 3/4" DOUBLE WASHED STONE ° \\ EXISTING SEPTIC COMPONENTS TO BE 120" PERC. TEST WAIVED ¢ ° 0000000�0000�000000000 ° °. I PUMPED, CRUSHED& REMOVED FROM 5 �„6' - 5 OUTLET 20'x30' LEACHING FIELD/3 LATERALS T IPOUT AROUND SYSTEM TO "C" HORIZON MIN DEPTH 4'-61/2 4'-1" LIQUID LEVEL D -BOX STRIPOUT (30'x40') V 9.27 BOTTOM OF END OF PIPE 4'-4" INV.=9.69 INV.=9.42 INV:=9.52 ELEV n V. 8.77 BOTTOM OF STONE LEWIS .r' 5.56 - 1 BAY .• . ,., . 6" BASE OF CRUSHED STONE OR MECHANICALLY COMPACTED TEST PIT #1 ADJ. GW. ELEV 3.77 1,500 GALLON PRECAST TIDAL WATER ELEV. 2.5 CONCRETE SEPTIC TANK LOCUS MAP\ I #18 COLUMBUS AVENUE #14 COLUMBUS AVENUE NOT TO SCALE: I ASSESSORS MAP 22 I ASSESSORS MAP 22 PARCEL 443 PARCEL 442 ` I I D.T.H. #1 DATE: OCTOBER 19, 2005 GROUND ELEV 8.1 j NO GROUNDWATER CONCRETE BOUND 10.00' J I I 90.00' FOUND & HELD 1 FILL A o LOAMY SAND 10YR 3/2 B 1Do- 00, / MEDIUM SAND 7.5YR5/8 I _ I \ r r 1 1 ELEV = 2.85 C , ` MEDIUM SAND 2.5Y 6/2 ELEV = (-1.9) BY BOH DUE TO G.W. I I � N ° � ° ° / SITE IN ACCORDANCE WITH TITLE 5. PROPOSED EXISTING IMPROVEMENTS DEPICTED INDICATES DEEP i 5 / DTH o ° 16x32 POOL a ° N47'25'00"E HEREON AS DOTTED LINES ARE TO 1Do- 00, / : j 'GALLO'N'GALLO'N SEPTIC ? o B.O.H. I _ I \ r r 1 1 ••C.° ° ci (� I BE REMOVED SITE. , ` - \ / 42" A. VON HONE \ \ � \ GROUNDWATER - - / 1 a ° ° - � SOIL EVALUATOR. I \ RO OS PO L F NC \ 1 t1 0, ........... ............... ......... PROPOSED INDICATES MICHAEL & JUDITH McKAY _ _ / i D. MEYER DRAINAGE DEPRESSION \\ \\ \ 9.2 L� ...�... ,... ...... 9 I o o P -1A 44" PERC TEST 64" INDICATES GROUNDWATER ;8 SHORE RD. - - - - - - ' BACKHOE OPERATOR. , (PER .YARMOUTH CONSERVATION OFFICER) / \ o ° \.............. �'O \ PROPOSED _ _ 48" ' A & 8 CANCO / �' `_- - - 10x14' EXISTING 52„ SOIL TYPE: 1_ <2 MIN. PER INCH / \ \ \ w I SHED BUILDING .12 PERC RATE: LOADING RATE: 0_74 GAL/SF/MIN /� ASSESSORS MAP 22 I ..... °.... ............ ... PARCEL 432 63" I 1 ° o ° ° ..... •• NOTES WELL MIW-29 , ----------- 64" ZONE: A i ° ° ° ° `�0. ?� FLOOD VENTS TO BE INSTALLED LEVEL: 8.2I / ° ;. ° c .........�........... PER ARCHITECTURAL PLANS ADJ: 1.7- / ° \ USE BOH ALLOWED ADJ. OF 1.0' --- 4 ° \\ EXISTING SEPTIC COMPONENTS TO BE 120" PERC. TEST WAIVED ¢ ° a ° °. I PUMPED, CRUSHED& REMOVED FROM ELEV = (-1.9) BY BOH DUE TO G.W. I I � N ° � ° ° / SITE IN ACCORDANCE WITH TITLE 5. PROPOSED EXISTING IMPROVEMENTS DEPICTED INDICATES DEEP i 5 / DTH o ° 16x32 POOL a ° z HEREON AS DOTTED LINES ARE TO #1 �_ ` / / TEST HOLE ■.® 52' INDICATES ADJUSTED : j 'GALLO'N'GALLO'N SEPTIC ? o ° e • ••C.° ° ci (� I BE REMOVED SITE. '- / - .... I GROUNDWATER - - / 1 a ° ° - � L.....:. I I I 7/ HYDRANT TAG BOLT I 1 t1 0, ........... ............... ......... PROPOSED INDICATES MICHAEL & JUDITH McKAY _ _ / i \ ELEVATION 9.48 I \ ,, i ...�... ,... ...... I .. I I o o P -1A 44" PERC TEST 64" INDICATES GROUNDWATER ;8 SHORE RD. - - - - - - ' ° o o ° \.............. ASSESSORS MAP 16 PROtSED DRASS AREA /6 PARCEL 10 ---- - ° ^.° i1 o° ° I PROPOSED \ 00 --------- o 4 BEDROOM \ PROPOSED 9 TOPDFNDLEL 12.5 \I I ° ° APRON E ° DATUM: I :PROPOS--.D 150 DTH #111 z I \ VERTICAL DATUM: NGVD 1929 I \\ : j 'GALLO'N'GALLO'N SEPTIC ? II 10.0 00. - 0 1 BENCH MARK SET: TOP OF CONCRETE BOUND \\ - � L.....:. I I I 7/ HYDRANT TAG BOLT I 1 t1 0, ........... ............... ......... PROPOSED III \ ELEVATION 9.48 I \ - - ;I ...�... ,... ...... .... , o o \\ SLAB ELEV 8.5 o \.............. PROtSED DRASS AREA \I N/F I� JON & JACQUELINE SIDOROVICH GENERAL NOTES: 1. ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO D.E.P. TITLE V AND THE TOWN OF YARMOUTH RULES AND REGULATIONS FOR SUBSURFACE DISPOSAL OF SEWERAGE, 2. AT LEAST ONE ACCESS POINT OVER TANK TEES SHALL BE ACCESSIBLE WITHIN 6" OF FINISH GRADE, WITH ANY REMAINING ACCESS PORTS BROUGHT TO WITHIN 12 OF FINISH GRADE. 3. ALL COMPONENTS OF THE SANITARY SYSTEM SHALL BE CAPABLE OF WITHSTANDING H-10 LOADING UNLESS THEY ARE UNDER OR WITHIN 10' OF DRIVES OR PARKING AREAS THEY MUST WITHSTAND H-20 LOADING. 4. THE EXCAVATION CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTILITIES PRIOR TO ANY EXCAVATION. 5. ANY MASONRY UNITS USED TO BRING COVERS TO GRADE OR WITHIN 6" OF GRADE SHALL BE MORTARED IN PLACE. 6. FINISH GRADE SHALL HAVE A MINIMUM OF 0.02 FEET PER FOOT OVER THE S.A.S. AND DISTRIBUTION BOX. UCTED OF 7. SEPTIC TANK SANITARY TEES SHALL BE CONSTR I SCHEDULE 40 PVC AND SHALL EXTEND A MINIMUM OF 6' ABOVE THE FLOW LINE AND SHALL BE ON THE CENTERLINE AND \ 1 LO- - - -- - _ - w - _ - - - - LOCATED DIRECTLY UNDER THE CLEAN OUT MANHOLES. PROPOSED 20' I T - -I� - - - - J 8. HE INLET PIPE INVERT ELEVATION SHALL BE NO LESS THAN x 30' S.A.S I \ la I LIJ o INCHES NOR MORE THAN 3 INCHES ABOVE THE INVERTof I~ I: Ia ELEVATION OF THE OUTLET PIPE. I N 9. THE SEPTIC TANK SHALL HAVE A MINIMUM COVER OF 9 INCHES 1 �9��' 0 1. a A 10. THE OUTLET SANITARY TEE SHALL BE EQUIPPED WITH A GAS SOIL REMOVAL 1 �� I: z ?O• BAFFLE, 4 INCHES IN DIAMETER AND CONSTRUCTED OF 4 PVC 4' 6' 6' 4' 11. ALL PIPES SHALL BE SCHEDULE 40 PVC SEWER PIPE AND TO ELEV F " \ I 5' SHALL BE SLOPED 1/4 INCH PER FOOT MIN. EXCEPT FOR THE OR TOP OF C 5' �W I: LAYER \ IIS _j: / FIRST TWO FEET OUT OF THE DISTRIBUTION BOX WHICH SHALL BE LEVEL 40ML POLY LINER h v i 12. CHANGES OR REVISIONS TO SEPTIC DESIGN REQUIRE NOTIFICATION ON ALL SIDES \ OS 110a o TO YARMOUTH B.O.H. AND DESIGN ENGINEERS REVIEW AND APPROVAL WITH RETAINING p 13. LAND SURVEY AND TOPOGRAPHIC DATE BY EAS SURVEY. WALL. EL 6 - 10 12' I 10.5 �� - ----- Tp _.,- PRO OSED IN ERL92KING 7:5 �I� ' CONCRETE BOUND CONCRETE BOUNR 5' BLO K RETAINING- WALL I WA. -(?L CONSTRUCTION NOTES: FOUND & HELD FOUND & HELD 1. CONTRACTORS /INSTALLERS SHALL VERIFY GRADES AND 71,62' -' i� I S17'25'00"W 100.00' ELEVATIONS AND SITE CONDITIONS PRIOR TO COMMENCING i I HYDRANT �� WORK ON THE SITE. �/ I I WATER MAIN 2. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT I I IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 3. VEHICULAR TRAFFIC, PARKING OF VEHICLES AND PLACING MATERIALS OVER THE SEPTIC TANK, DISTRIBUTION BOX AND S.A.S. AREA IS PROHIBITED MASSACHUSETTS AVENUE SYSTEM DESIGN DESIGN FLOW 4 BEDROOMS AT 110 GPB/D 440 GPD REQUIRED SEPTIC TANK 440 x_2 _ _88_0_ GAL. SEPTIC TANK PROVIDED 1500 SIZE OF LEACHING FACILITY REQUIRED DESIGN PERC RATE __._<-2 ----- MIN./INCH LONG TERM APPL. RATE-9.-Z-4--GPD/S.F. SIZE OF LEACHING SYSTEM PROVIDED: 440 _ 0.74 SF/GPD = -595-S.F. MIN. REQUIRED USING 20' x 30' LEACHING FIELD BOTTOM = 20.0' x 30.0' = 600 S.F. 600 S.F x 0.74 = 444 GPD 444 GPD PROVIDED > 440 GPD REQUIRED = 4 GPD RESERVE NO GARBAGE DISPOSAL / GRINDER ALLOWED LOCUS INFORMATION CURRENT OWNER M.A. REALTY TRUST ADDRESS 4 JANNOR WAY WEST YARMOUTH MA 02673 PLAN REFERENCE PLAN BOOK 25, PAGE 49 DEED REFERENCE DEED BOOK 10468, PAGE 268 ZONING DISTRICT R-25 SETBACKS FRONT 30' SIDE 15' REAR 20' FLOOD ZONE "A-12", DATED 7/2/92 PANEL #250015-5D, ELEV 12.0 _.ASSE-350RS - M -AF; 2/ ..... _ PARCEL 431 LOT AREA 14,000± S.F. EXISTING BLD/DECK COVERAGE 2,835± S.F. (20%) PROPOSED BLD/SHED/POOL COVERAGE 2,942± S.F. (21%) 25% ALLOWED SITE AND SEWAGE PLAN r vpC -,v #87 MASSACHUSETTS AVENUE IN WEST YARMOUTH, MASSACHUSETTS SCALE 1" =10' DATE: APRIL 7, 2006 PREPARED FOR: TOM FINELLI 2 BAY PATH LANE SOUTHBOROUGH MA 01772 ^ o!o tNOFMQ 1 PREPARED BY: �(H�oFessv A R _-� DARREN M. MEYER, EDWARD oyc� "MEYER N P.O. BOX 981 STONE N No.28980 RNo. 01 TE E. SANDWICH P°TsPF�,ST SgNTAR PN MA 02537. _ 1ALL 0� PH. (508) 362-2922 `�!,•� I :PROPOS--.D 150 DTH #111 z I : j 'GALLO'N'GALLO'N SEPTIC ? II TANK O - 0 1 c I Q Q - � I w I I 7/ I ........... ............... ......... PROPOSED III � 12.0 I I GARAGE I o o SLAB ELEV 8.5 \.............. N/F JON & JACQUELINE SIDOROVICH O' w I #81 MASSACHUSETTS AVENUE .12 i ASSESSORS MAP 22 I &� i PARCEL 432 I \ 1 l w I' 7. SEPTIC TANK SANITARY TEES SHALL BE CONSTR I SCHEDULE 40 PVC AND SHALL EXTEND A MINIMUM OF 6' ABOVE THE FLOW LINE AND SHALL BE ON THE CENTERLINE AND \ 1 LO- - - -- - _ - w - _ - - - - LOCATED DIRECTLY UNDER THE CLEAN OUT MANHOLES. PROPOSED 20' I T - -I� - - - - J 8. HE INLET PIPE INVERT ELEVATION SHALL BE NO LESS THAN x 30' S.A.S I \ la I LIJ o INCHES NOR MORE THAN 3 INCHES ABOVE THE INVERTof I~ I: Ia ELEVATION OF THE OUTLET PIPE. I N 9. THE SEPTIC TANK SHALL HAVE A MINIMUM COVER OF 9 INCHES 1 �9��' 0 1. a A 10. THE OUTLET SANITARY TEE SHALL BE EQUIPPED WITH A GAS SOIL REMOVAL 1 �� I: z ?O• BAFFLE, 4 INCHES IN DIAMETER AND CONSTRUCTED OF 4 PVC 4' 6' 6' 4' 11. ALL PIPES SHALL BE SCHEDULE 40 PVC SEWER PIPE AND TO ELEV F " \ I 5' SHALL BE SLOPED 1/4 INCH PER FOOT MIN. EXCEPT FOR THE OR TOP OF C 5' �W I: LAYER \ IIS _j: / FIRST TWO FEET OUT OF THE DISTRIBUTION BOX WHICH SHALL BE LEVEL 40ML POLY LINER h v i 12. CHANGES OR REVISIONS TO SEPTIC DESIGN REQUIRE NOTIFICATION ON ALL SIDES \ OS 110a o TO YARMOUTH B.O.H. AND DESIGN ENGINEERS REVIEW AND APPROVAL WITH RETAINING p 13. LAND SURVEY AND TOPOGRAPHIC DATE BY EAS SURVEY. WALL. EL 6 - 10 12' I 10.5 �� - ----- Tp _.,- PRO OSED IN ERL92KING 7:5 �I� ' CONCRETE BOUND CONCRETE BOUNR 5' BLO K RETAINING- WALL I WA. -(?L CONSTRUCTION NOTES: FOUND & HELD FOUND & HELD 1. CONTRACTORS /INSTALLERS SHALL VERIFY GRADES AND 71,62' -' i� I S17'25'00"W 100.00' ELEVATIONS AND SITE CONDITIONS PRIOR TO COMMENCING i I HYDRANT �� WORK ON THE SITE. �/ I I WATER MAIN 2. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING REGULATIONS. OWNER / APPLICANT I I IS TO OBTAIN SUCH DETERMINATION FROM APPROPRIATE AUTHORITY. 3. VEHICULAR TRAFFIC, PARKING OF VEHICLES AND PLACING MATERIALS OVER THE SEPTIC TANK, DISTRIBUTION BOX AND S.A.S. AREA IS PROHIBITED MASSACHUSETTS AVENUE SYSTEM DESIGN DESIGN FLOW 4 BEDROOMS AT 110 GPB/D 440 GPD REQUIRED SEPTIC TANK 440 x_2 _ _88_0_ GAL. SEPTIC TANK PROVIDED 1500 SIZE OF LEACHING FACILITY REQUIRED DESIGN PERC RATE __._<-2 ----- MIN./INCH LONG TERM APPL. RATE-9.-Z-4--GPD/S.F. SIZE OF LEACHING SYSTEM PROVIDED: 440 _ 0.74 SF/GPD = -595-S.F. MIN. REQUIRED USING 20' x 30' LEACHING FIELD BOTTOM = 20.0' x 30.0' = 600 S.F. 600 S.F x 0.74 = 444 GPD 444 GPD PROVIDED > 440 GPD REQUIRED = 4 GPD RESERVE NO GARBAGE DISPOSAL / GRINDER ALLOWED LOCUS INFORMATION CURRENT OWNER M.A. REALTY TRUST ADDRESS 4 JANNOR WAY WEST YARMOUTH MA 02673 PLAN REFERENCE PLAN BOOK 25, PAGE 49 DEED REFERENCE DEED BOOK 10468, PAGE 268 ZONING DISTRICT R-25 SETBACKS FRONT 30' SIDE 15' REAR 20' FLOOD ZONE "A-12", DATED 7/2/92 PANEL #250015-5D, ELEV 12.0 _.ASSE-350RS - M -AF; 2/ ..... _ PARCEL 431 LOT AREA 14,000± S.F. EXISTING BLD/DECK COVERAGE 2,835± S.F. (20%) PROPOSED BLD/SHED/POOL COVERAGE 2,942± S.F. (21%) 25% ALLOWED SITE AND SEWAGE PLAN r vpC -,v #87 MASSACHUSETTS AVENUE IN WEST YARMOUTH, MASSACHUSETTS SCALE 1" =10' DATE: APRIL 7, 2006 PREPARED FOR: TOM FINELLI 2 BAY PATH LANE SOUTHBOROUGH MA 01772 ^ o!o tNOFMQ 1 PREPARED BY: �(H�oFessv A R _-� DARREN M. MEYER, EDWARD oyc� "MEYER N P.O. BOX 981 STONE N No.28980 RNo. 01 TE E. SANDWICH P°TsPF�,ST SgNTAR PN MA 02537. _ 1ALL 0� PH. (508) 362-2922 `�!,•�