Loading...
HomeMy WebLinkAbout83-1759 - Sewage Disposal System 2TYPICAL 1500 GALLON SEPTIC TANK abewM4 1N41P"Kltnt 10' min, from - :1P"atn PROPOSED Foundation house to septic tank 'NOTE: ALL PIPES ARE TO BE 4" SCHEDULE 40 P.V.C. NOT TO SCALE ?�°d0e: Septic tank coven must be @� cls T.O.F. elev. = 16.00 within 6 In, of finished grade 3-24• DIAM. ACCESS MANHOLES M �i f� ` Croda over Septic Tank - 15.00 Grade over O -Boz - 15.00 ,-�iOde ow SAS - EL 15.00 SECTION A -A $ / PROFILE VIER' OF LEACHING SYSTEM 5 e 0.02 Not to Scale 3 HOLE 50.04 (H-20) DIST. BOX 3' M<aimum Corer �ToP of SAS-EIev.- 13.00 s• N t/s" - t/t" reeves leekewee 74' /4• ter 1/4 • rew4 t1,uAes 81w,ee „I \ \ ` „( t NEV PIPE �' o NEW 1,500 GAL s- 0.010" er TOOL 4' PVC (CAPPED) MSPECTION PORT TD BE INLET / \ ' 25' Effe ve Oe FROM FOUNDATION P) C) SEPTIC TANK 5• ��• Depth Depth INSTALLED AND TD BE WnNIN e• aF GRADE INLET \y/ t\l/ t`'/ II H-10 THE ACCESS COVERS FOR THE SEPTIC TANK, p ; CONCRETE FULL FOUNDATIO d II 4 '- 4'-� o j II DISTRIBUTION BOX AND LEACHING COMPONENT y d sX oe wi..,.ea�biorbNwne ,NAr+aa Ile „r-..,�-rte,-. T.__,�.' SHALL BE RAISED TO WITHIN 6' OF II II B I 24" EffeOfive •` ''-'••n'4 "^'` *r' SHALL B GRADE. , SYSTEM PROFILE ; d v u I Efn tie wdtb I _�Sidewali STEEL REINFORCED PRECAST CONCRETE INSTALL TUF-TITE GAS BAFFLES OR EQUALS i 6 Units a 7' 42' PLAN VIEW ON ALL OUTLET TEE ENDS Not to Scale C N d w TO ELEVATION51 STRI UT 21000UND � 2 o L - - - J s '� GENERAL NOTES S c u CD 0 1. Contractor is responsible for Digsafe notification 6 In.of 3/4'-1 1/2" w Holton of Test Hole 2 Elev." 3.50 Effective Length and protection of all underground utilities and pipes. compacted stone • Obs. Groundwater - Test Hole 1 Elev. 3.5}24' REIAOYABIF COVERS 2. The septic tank O distri ution box shall be set v ADJ. Groundwater - Test Hole 1 Elev.- 5.20 SOIL ABSORPTION SYSTEM (SAS) level on 6° of 3%4 -1 1/2" stone. 3. Bockfill should be clean sand or grovel with no Note: Remove toll down to med sand layer & replace with (OR EQUIVALENT) (slay. 11.00) & replace with clean coarse sand w/perc. NOTE: OVERALL HEIGHT OF INFILTRATOR IS 30" /EFFECTIVE HEIGHT IS 24" INLET NOTE: ALL COMPONENTS MUST HAVE RISERS TO WITHIN 6" BELOW GRADE rate less than or equal to 2 min./in. before &after placement I Note: Certification of Fill Material Required. 5' 4 Before and After Placement by Selve Analyses �N/F YcBRIDE N/F NICBAEL E. KENNEDY 4. 3m„• Cleorenp B min. 2' min. Inlet to ouVa"u"e. m•. �7Ru�I.T r A E= r ;. qs stones over 3 In size. ,r N,r•T r!' 4. This system is subject to inspection during ng instalat' on _({ by Carmen E. Shay - Environmental Services, Inc. OUTLET ,�' 5. The contractor shall install this system in accordance U 5• -7' with Title V of the Massachusetts state code, the approved plan ' 4'-0• min. and Local Regulations. • Liquid depth 6. If, during installation the contractor encounters any soil conditions or site conditions that are different from those shown on the soil log or in our design 's' -e•- installation must halt & immediate notification be ASSESS. NAP 39 PARCEL 103 mode to Carmen E. Shay - Environmental Services, Inc. ASSESS. NAP 39 PARCEL 108 CROSS SECTION END -SECTION 7, No vehicle or heavy machinery shall drive over the septic system unless noted as H-20 septic components. N/F STEVEN AS'TULFI 8. Install Tuf-Tite gas baffles or equals on all outlet tee ends. QL 6'4j) 9, All Distribution Lines shall be 4" diameter Sch. 40 NSF PVC pipes. ASSESS. NAP 39 PARCEL f0f ; 10. All solid piping, tees & fittings shall be 4" diameter N/F NARY N BANNON �� 1S `, Schedule 40 NSF PVC pipes with water tight joints. ASSESS. AAP 39 PARCEL foo 1 S0 X00 11. MUNICIPAL WATER is AVAILABLE at Site and Surrounding Properties. Co 1 o -• \ ` f / 1 // nWF#A11, ' �> IPJ NOTE - CB rDD.H� _ _ - \ t I ( O O THE PROPERTY LINES AND WELTLAND DELINEATION ARE COMPILED FROM THE BASE PLAN AND SURVEY DATA GENERATED BY � I !� �4 BSC GROUP OF YARMOUTH, MA, DATED 12-14-05 -/ 8.701 \�N%10 ; 1 1 ry I `L `, ENTITLED"EASEMENT PLAN OF LAND OF BAXTER AVENUE, YARMOUTH, MA- (, All ROOF Runoff to be Diverted into 1 ( �, i / I Subsurface Dry -Wells It �] , PROPOSED LOT COVERAGE = 2.3 PERCENT \ ( 3 ` � PROPOSED HOUSE 1966 S.F. CB D.H. " . {h^IF#A� 11 1` (\ i0"� i ' ¢3.�'' 0" \ 1`, 1� LOT SIZE _ 84,2e7 S.F. FND \ W 'I`'t�G\'; �~ 1 1�U THERE ARE WETLANDS LOCATED WITHIN A 200' RADIUS OF THE SAS. ent 1\,1` y`` �`.`\` t i 11 -r\\` 1` Tr1 \ Note: Remove soil down to W. 11.00 (Estimated)CR4 & 111 r^ y \�� •. t'lE`#A9 \�`, `� I) `'` 1\ ', nk �\ replaceor to 2clean./In. before k a Parc. rate les than or 1 'S WETLAND FLAGGING AND BASE MAP GENERATED BY BSC GROUP 1 DATED DECEMBER 14, 2005 ZONING DISTRICT = R-25 N/F ALDO NAE HVEBER \`` \1 1i7 \ 1 5i 3', f SETBACK RQU 14 I kk REMENTSASSESS. NAP 39 PARCEL 1f0 \W A8 IFRONT = 30' HOLE2 V lb 1.50 09" to REAR 20' \ 1\ y;4 Y 1 1 4 - 38 - M ASSESSORS MAP - 29 PARCEL 101 & 102 OVERGROWN BOG I 1 1 `, `, `, \ O� ` ` /tat NEW 500 GAL a . � � SEPBO\TANK ,` a \. e l �_ _ �.p�- "H.7• '�� '' ' ' ' LOT #4 tvY[f \I `\ ', 1` BSMNT rL EL - 0.50 ? ______ _ ' �^ 84,287 S. F. +/- �` A S ,1 \ `OS `. TOFFNSFUR - nm \'\ °- e% vtt�• •� • ° 1 - oaoivar.Cr�" ' - TA ', FEMA FLOOD ZONE DISTRICT: r `. ` •y PRDPaSED� `\ It FLOOD ZONE C AS SHOWN ON .� !7,614 S. F. +/- OF WETLANDS ,`,` `, , PROPOSED _ - y�._ _____, �'' L\2 48,879 S. F. +/- OF UPLANDS :I `,` ` \: `�`,\ 4 BEDROOM ; SIA E1EK.- lssq _ - �'`,1 COMMUNITY PANEL 250015 0005 D I. ` ` �e :•.rs. W TRANS 1 PLOT 1 \ :* `' A6Ilk j \` i s ��`: " ' PROJECT BENCH MARKSB . F 1 ;; HiSC:'„---____.-- - 1 ; yS. FND° D.H. CT ,', LEGEND ELEV. 15.00 �1 O �`� T�g'Ak1E'^� -15 ELEV. 14.00 (NGVD) A '1 11RR�OeP�OSED' �" ,```1,1 D"ell \yfo! Uwvn" ' IP FND �1 �rT1 \ `1 -------------��jj 8X0 DENOTES PROPOSED NIP NARY A. GLEASON M (O r ` _ %(/' \`, �\ `` \� \`, \ IP FND NIP JOAN E. CUNNINGS ' 1 SPOT GRADE A / \ __ ____�S \x! �( DENOTES EXISTING ASSESS. NAP 39 PARCEL f f 1 / n ' iri \ , ` y Lf 1 W A4 \ \ Gn\ ASSESS. NAP 39 PARCEL foo X 104.46 SPOT GRADE :Sit+ k`"N°N \`, �. `�G\ \ PL PROPERTY LINE 9,oOFIF' A3 ``, \ ��,\ O -�- PROPOSED CONTOUR ` 3 i i r Q �` ` ` ``� ``�\�`� \�\ G� Note: LIMIT OF WORK i5 EOUAL TO 35 FEET 11 1}77• .c\�.� y \� \\ �\ _\ I FROM EDGE OF BVW AND HAY BAIL LINE 97---------97 EXISTING CONTOUR k. IJ 730 38 .% ;' (s) A27 -Ii {1 ;\ 11I---------------14 t PERCOLATION DEEP TEST HOLE TEST LOCATION = /r j'---------------- \ O WF#A2 WETLAND FLAG FND.H. / 1 , r %'✓ -- o----�7 FENCEDR --------a0 N/F DENNIS L. KAELEY ` 8 PRIVATE DRINKING WATER WELL,` --- ASSffSS. NAP 39 PARCEL f12 \ /' , , I , '` �' REVISIONS N/F DENNIS L. A.3'ELEY \ /' i i 11 7 Note: ELEVATION OF TOP OF PROPOSED FOUNDATION ASSESS. APAP 39 PARCEL 113 \ �' �, /' IS TWO FEET ABOVE MAXIMUM ROAD HEIGHT IN FRONT of LOT NO. DATE: DEFINITION PERCOLATION TEST \ 1`, Added Dry & Deck \ / / 7�24�06 pr r (:nn C:nm MPet'nn Date of Percolation Test: APRIL 12, 2006 Test Performed By.. BSC GROUP Results Witnessed By. AMY VON HONE, R.S. ( YARMOUTH B.O.H.) Excavator: UNKNOWN Percolation Rate: 2 min./inch ® 42" BELOW GRADE. Test Hole No. 1 DEPTH SOILS ELEV. 0 15.00 PROPOSEDSUBSURFACE Loamy Sand 10YR 4/3 0"-B• Ar 14.67 Loamy San ALLtDnimBoxU�T RPM Au THE SST LEVEL F BOX SHAH BE 12• CONCRETE COVER SET IML FOR AT LEAST Z R. 10 YR 5/B 8"-24" Be 13.00 Garbage Grinder: No Leaching Capacity Proposed: 440 Gal./Day Sandy Loam � m S A7 y YARMOUTH, MA 10YR 5/4 Septic Tank : - 2 x 550 Gal./Day = 1100 USE NEW 1,500 GAL Septic Tank. 24"- 60" C, 10.00 - s.s• cuTLU ( 1z• INLET Med, Sand IOYR 7/1 '� t: e• �� 60"-132" Ce 4.00 Sidewall Area: 0.74 gal./sq. ft. x 188 sq. ft. =139 gallons Test Hole No. 2 DEPTH SOILS ELEV. 0 14.50 PROPOSEDSUBSURFACE Loamy Sand 1 OYR 3/3 0"-12" Ar 13.50 Loamy San ALLtDnimBoxU�T RPM Au THE SST LEVEL F BOX SHAH BE 12• CONCRETE COVER SET IML FOR AT LEAST Z R. 10 YR 5/B 12"-42" By 11.x0 Garbage Grinder: No Leaching Capacity Proposed: 440 Gal./Day COARSE SAND � m S A7 y YARMOUTH, MA 10 YR 8/4 Septic Tank : - 2 x 550 Gal./Day = 1100 USE NEW 1,500 GAL Septic Tank. 42"- 132 G 3.50 - s.s• cuTLU ( 1z• INLET SOIL ABSORPTION AREA: Using percolation rate of <2 min./inch '� t: e• �� Parc #1 ®Test Hole #1 8 HITARIA� EAST FALMOUTH, MA 02536 Depth to Perc: 24" to 42" Perc Rate= 2 min./inch TEL/FAX : 508-539-7966 Groundwater Observed ® ELEV 3.5 0 TH-2 BOTTOM OF TEST HOLE Elev. = 132" MIW-29/ZONE A - INDEX = 8.2 for 4/06 SCALE: 1 "=30' DRAWN BY: CES DATE: JUNE 30, 2006 ADJUSTMENT = 1.3 FEET PF OJECT#SD-938pp.dwgFILENAME: SD -938 SHEET 1 OF 1 ADJUSTED H2O Elev. = 5.2 �4 JUL 2 5 RECEIVE PROPOSEDSUBSURFACE PRE PARED FOR: SEWAGE DISPOSAL SYSTEM ALLtDnimBoxU�T RPM Au THE SST LEVEL F BOX SHAH BE 12• CONCRETE COVER SET IML FOR AT LEAST Z R. Design Calculations Number of Bedrooms: 4 Equivalent to 440 Gal. Do q Gal./Day OF 4J\SN�Auss4c .'� 01 E LOT 4 BAXTER AVENUE T. 3 - s- ouT1Er"`^•''i �•"• z• KNOCK 'TS Garbage Grinder: No Leaching Capacity Proposed: 440 Gal./Day � m S A7 y YARMOUTH, MA Septic Tank : - 2 x 550 Gal./Day = 1100 USE NEW 1,500 GAL Septic Tank. MR. PAUL SCHLAEGAL - s.s• cuTLU ( 1z• INLET SOIL ABSORPTION AREA: Using percolation rate of <2 min./inch '� t: e• �� Bottom Area: 0.74gal/sq. ft. x 420s . ft. = 311 q gallons Sidewall Area: 0.74 gal./sq. ft. x 188 sq. ft. =139 gallons 25 B R 0 W N FI E L D ROAD PREPARED BY: a• - SCH. 4a To 1,75- Providing: = 450 gallons OF q PLAN SECTION CROSS-SECTION �JkA o�� CAR�HEY E. SHAY Use: (4) 3050H-20 INFILTRATOR CHAMBERS, HAVING A 2' EFFECTIVE DEPTH, BRIDGEWATER, MA 02324 CA N 3 HOLE DISTRIBUTION BOX - H-10 LOADING (4' W x 7' L) TO BE USED WITH 4' OF WASHED STONE ON THE SIDES AND o `\ E ENVIRONMENTAL SERVICES, INC. SHA N NOT TO SCALE 4' OF WASHED STONE ON THE ENDS. n sz 1 'm r) - Q 1 Q7 _ r 11 ._ P.O. BOX 627 Parc #1 ®Test Hole #1 8 HITARIA� EAST FALMOUTH, MA 02536 Depth to Perc: 24" to 42" Perc Rate= 2 min./inch TEL/FAX : 508-539-7966 Groundwater Observed ® ELEV 3.5 0 TH-2 BOTTOM OF TEST HOLE Elev. = 132" MIW-29/ZONE A - INDEX = 8.2 for 4/06 SCALE: 1 "=30' DRAWN BY: CES DATE: JUNE 30, 2006 ADJUSTMENT = 1.3 FEET PF OJECT#SD-938pp.dwgFILENAME: SD -938 SHEET 1 OF 1 ADJUSTED H2O Elev. = 5.2 �4 JUL 2 5 RECEIVE