Loading...
HomeMy WebLinkAboutEngineered Plan - 20164 ASSESSORS MAP:t;� PARCEL: FLOOD ZONE: bT Awb1cw2u&_— -- REFERENCE: LOCATION MAP 11 1zz.00 ��► K� '3'�J �iwJA C0L11 mta4� TEST HOLE LOGS SOIL EVALUATOR: —)IOA)Irr? 43, ��.j WITNESS: Am-\/bw DATE: 19 IWIC2 PERCOLATION RATE: U�II 1 40 IV- TH-I TH-2 GJ LO Q.,.I I' SEPTIC SYSTEM DESIGN FLOW ESTIMATE BEDROOMS AT IID GAL/DAY/BEDROOM -GAL/DAY SEPTIC TANK ��) GALIDAY x 2 DAYS - �� GAL USE I06D GALLON SEPTIC TANK E1L,1 ✓IQ C=AW 0,e(-, c`• — S I L ABSORM-0N SYS'1' M use. L� n� ►a -c,,, c.�u���� w r 1) The installation shall cornpcvith Title V auJ Town of gtg0j0qj Board ot. Ilealth Regulations. 2) The installer shall verify the location of utili(ies, sewer inverts and septic components prior to installation and setting base elevations. 3) All gravity septic piping to be 4 inch Sch 40 PVC at 1/8" per foot. The first two feet out of the d -box to the leaching shall be level. 4) This plan is not to be utilized for.property line determination nor any other purpose other than the proposed system installation. 5) All septic components must meet Title V specifications. I 6) Parking shall not be constructed over 1110 septic components. 7) Tile property is bounded by property corners and property lines. 8) The property owner shall review design considerations to approve of total design flow and number of bedrooms to be considered for design. Receipt of payment for the plan and installation based on the plan shall be deemed approval of the design flow by the owner. 4) The existing leaching or cesspools shall be pumped and filled with material per Title V abandonment procedures. Those within the proposed SAS shall be removed along with contaminated soil and replaced with clean sand per Title V specs. 10) System components to be 10 feet from water Iine. Sewer lines crossing the water line shall be sleeved with 4 inch SCI 140 PVC with ends grouted if applicable. The proposed SAS is being installed below the water service line. The line is to be sleeved as aforementioned and maintained in place. 11) If a garbage grinder exists it is to be removed and is the responsibility of [lie owner to ensure such. 12) The installer is to take caution in excavation around the gas line if such exists. 13) The installer shall verify the location, quantity and elevation of the sewer lines exiting the dwelling" rior to the installation. 14) This plan is representative only that a system can fit on a property meeting Title V requirements. SIDE AREA: 2x�-}- BOTTOM AREA: ' X tz ' X ni in 31 I� SEPTIC SYSTEM SECTION ;uJiW6" �bv O13 10" 40 b GAL SEPTIC TANK �'armouth Health Department / '' / —1/1—�> Date N DATE HEALTH AGENT jq114 /a D -n 70