Loading...
HomeMy WebLinkAboutReview Checklist �-''/,�'l� TOWN OF YARMOUTH ° SEWAGE PLAN REVIEW CHECKLIST 1Location: A.M._� Lot��U Zone of Contribution: In Out �ea.ge , Commercial: Residential: �.�� Street: � / � Village: Floor Plan: ✓ #Bedrooms: Owner: Installer: � Address: Phone: Phone: Builder: Engineer: Address: Phone: '" - � Phone: " � i` --�'�r-� �2' �� � N/A YES NO 1.Re uired#of co ies received t,�/ 2.Date of soils exam and ercolation test not older than 2 ears �� 3.4-5 ft of naturall occurrin ervious material, above water table 4.Foundation 2 ft above hi oint of road H.P.: Fnd: Var.: 5.Water line 10 ft from septic com onents Var.: 6.Benchmark indicated and shown-NGVD if near wetlands 7. S tic tank minimum 10 ft from foundation, deck Var.: v� 8.Leaching mini.mum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9.Leachin minimum 100 ft from wetlands Var.: - 10.Leaching minimum 150 ft from drinking welU25 ft irri tion well Var.: • 1 l.Tank/leaching minimum 10 ft from ro erry line Var.: 12.S stem meets all other setback r uirements Var.: <.�-� 13.Uses ad'ustment for maximum hi groundwater Var.: - 14.Leachin set 4-5 ft above ad'.water or bottom of test hole Var.: 15.System not in to or subsoil(A,B horizons)or 5'removal 16.Pro osed contours are suitable 17. S stem meets slo e r uirements-min. 1/8", '/4" referred 18. S stem meets breakout r uirements PVC liner: Wall: 19. Specified tee sizes are ro er, as baffle on outlet tee �.� 20. Sewage is under 10,000 gpd for arcel 21.No bage dis osal 22. S stem ad uatel sized for its intended use 23.Minimum 6"stone or com acted below tank and dbox 24.Manhole covers within 6"of grade, ump chamber cover to grade 25.Inspection ort on la.stic chambers/leach field 26.Electrical ermit for um chamber/S arate meter for du lexes 27.Pum system-2"line,wee hole,check valve,tee in dbox, um size 28. S tic tank/ ump chamber to be factory wat roofed �-� 29.Vent rovided if leaching below 3 feet,under drivewa / arkin _..� 30.Buoyancy calculations for tank/pum cha.mber :�/" 31.En ' eer to ins ect and cert' soils: wall: commerciaL• 32.Engineer/Registered Sanitarian and La.nd Surveyor stam s/si ature -�---"' 33.H-201oadin is subject to vehicular traffic, groundwater 34.Title V A lication and ermit fee,insta.11er si ture 35.Foundation footing min. 2 feet above ad'usted ground water for new house - 36.Deed Restriction r uired max. #bedrooms: max. flow: d 37.Check area lots for oundwater/Label groundwater in Assessor's Ma ' � Plan reviewed by: C� wo3io3