HomeMy WebLinkAboutReview Checklist � � /� -��
TOWN OF YARMOUTH
° SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. � � Lot �S � � Zone af Contribution: In Out'-�Acreage
� p� Commercial: Residential: � �
Street: � /"
Village: Floor Plan: �---"'� #Bedrooms: �
Owner: �'.�'_��G'�� t/l G�-- Installer:
Address: Phone: -
Phone:
.
Builder: Engineer:
Address: Phone: - �"
Phone:
N/A YES NO
1.R uired#of copies received
2.Date of soils exam and ercolation test not older than 2 ears
3.4-5 ft of naturall occurrin ervious material, above water table �._�
4.Foundation 2 ft above high oint of road H.P.: Fnd: Var.:
5.Water line 10 ft from septic com onents Var.: :_---'
6.Benchmark indica.ted and shown-NGVD if near wetlands ts�
7. Se tic tank minimum 10 ft from foundation, deck Var.: c..�'"
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: �.�
9.Leachin minimum 100 ft from wetlands Var.: ..�-- •
10.Leachin minimum 150 ft from drinking welU25 ft irri ation well Var.:
1 l.Tank/leachin minimum 10 ft from ro erty line Var.:
12. S stem meets all other setback r uirements Var.:
13.Uses adjustment for ma�mum hi groundwater Var.:
14.Leaching set 4-5 ft above adj.water or bottom of test hole Var.:
15. S stem not in to ar subsoil(A,B horizons}or 5'removal
16.Pro osed contours are suitable ��-
17. S stem meets slo e r uirements-min. 1/8", '/a" referred
18. System meets breakout re uirements PVC liner: Wall: L,�
19. S ecified tee sizes are ro er,gas baffle on outlet tee ��
20. Sewage is under 10,000 gpd for arcel �,.,�
21.No arbage dis osal �"�
� 22.S stem ad uatel sized for its intended use
23.Minimum 6"stone or com acted below tank and dbox
24.Manhole covers within 6"of grade, um chamber cover to ade
' 25.Ins ection ort on lastic chambers/leach field
26.Electrical ermit for um chamber/S arate meter for du lexes '
27.Pum stem-2"line,weep hole,check valve,tee in dbox,pum size
28. S tic tank/pum chamber to be factory wat roofed
29.Vent rovided if leachin below 3 feet,under drivewa /parkin -
30.Buoyancy calculations for tank/pum chamber
31.E ' eer to ins ect and cert' soils: wall: commercial:
32.Engineer/Re 'stered Sanitarian and Land Surveyor stam s/si ature ._.�.._
33.H-201oading is subject to vehicular traffic, groundwater _�
34.Title V A lication and ermit fee,installer signature :`,.,_i
35.Foundation footin min. 2 feet above ad'usted ground water for new house �'"���
36.Deed Restriction r uired max. #bedrooms: max. flow: d
37.Check area lots for groundwater/Label oundwater in Assessor's Ma
Plan reviewed by: (,��1 r�o3ios