HomeMy WebLinkAbout83-1802 - 4 - Drainage DetailsIa 0 0 n 8 3 k 4 BITUMINOUS CONCRETE SWALE DETAIL (NOT TO SCALE) BITUMINOUS i CONCRETE SWALE (SEE DETAIL) 6' STONE MZ02.4 MASS DPWDPW MASS STD. SPECS Dn ¢ A M2.02.4 MASS DPW STANDARD SPECS. SIEVE PERCENT SIZE PASSING i i 95%100% 41NCH O%-25% 2 1 INCH 0%-5% CB -2 12.50 -- } DOUBLE GRATE CATCH BASIN CB -3 12.50 -- 11.00 DOUBLE GRATE CATCH BASIN CB -4 14.50 LOW POINT 11.00 DOUBLE GRATE CATCH BASIN CB -5 13.50 -- 11.00 12' CB -6 1 -- 11.00 DOUBLE GRATE CATCH BASIN ' I I LRB -1 F.G. 10.80 -- LEACHING RECHARGE BASIN LRB -2 F.G. 10.80 i -- LEACHING RECHARGE BASIN LRB -3 F.G. 10.80 -- LEACHING RECHARGE BASIN LRB -4 F.G. 10.80 -- LEACHING RECHARGE BASIN LRB -5 F.G. 10.80 -- LEACHING RECHARGE BASIN LRB -6 F.G. 10.80 -- LEACHING RECHARGE BASIN yam` %.• . ." .�� `f, �. /1• OF LOAM .,� ., 3�•," ° •+ : AND SEED • a 3 4.0' a a.. `r• MIN. d ' %° PAVED WATERWAY :.? I ( `BERM ` >" :BERM ;: ± ii A i A °..� ° �•. LAYER COMPACTED GRAVEL SUBSURFACE {t � _ A SECTION W k 4 BITUMINOUS CONCRETE SWALE DETAIL (NOT TO SCALE) BITUMINOUS i CONCRETE SWALE (SEE DETAIL) 6' STONE MZ02.4 MASS DPWDPW MASS STD. SPECS Dn ¢ A M2.02.4 MASS DPW STANDARD SPECS. SIEVE PERCENT SIZE PASSING 81NCH 95%100% 41NCH O%-25% 2 1 INCH 0%-5% 1 I MIRAFI TM8 SLOPE REINFORCEMENT MAT TO BE INSTALLED PER MANUFACTURERS SPECIFICATIONS FULL WIDTH AND DEPTH OF GRASS LINED SWALE. GRASS LINED SWALE TO BE LOAMED (3 -MIN.) AND HYDROSEEDED ACCORDING M MIRAFI RECOMMENDATIONS t r GRASSUNED SWALE SWALE - PLAN VIEW OUTLETS TO LEACHING - RECHAGE BASIN 8' DIA HOPE PIPE PRECAST —CONCRETE RISERS -6" STONE - M2.02.4 MASS DPW STD. SPECS 24'x 48' OPENING 18' 24" MIN. 4' MIN. 40 MIN. LAYER NORTH AMEPoCAN GREEN C350 SHOULDER OF LOAM & NRF REINFORCEMENT MAT (OR HYDROSEED APPROVED EQUAL). (WSSM) BIT. CMM BERM — 2 2 2 r i COMPACTED o, MAX 1 PAVEMENT GRAVEL ) .,MAX 1 i MAXWAX PAVEMENT i (E 12'MIN r .. COMPACTED GRANULAR FILL ,1:12MIN. EXISTING COARSE ;. SAND OR COARSE. AN' FILL SWALE - SECTION GRASS LINED SWALE DETAIL '(NOT TO SCALE) DRAINAGE SCHEDULE OF ELEVATIONS STRUCTURE RIM INV. IN INV. OUT DESCRIPTION CB -1 12,50 -- 11.00 DOUBLE GRATE CATCH BASIN CB -2 12.50 -- 11.00 DOUBLE GRATE CATCH BASIN CB -3 12.50 -- 11.00 DOUBLE GRATE CATCH BASIN CB -4 14.50 -- 11.00 DOUBLE GRATE CATCH BASIN CB -5 13.50 -- 11.00 DOUBLE GRATE CATCH BASIN CB -6 12.50 -- 11.00 DOUBLE GRATE CATCH BASIN ' I I LRB -1 F.G. 10.80 -- LEACHING RECHARGE BASIN LRB -2 F.G. 10.80 i -- LEACHING RECHARGE BASIN LRB -3 F.G. 10.80 -- LEACHING RECHARGE BASIN LRB -4 F.G. 10.80 -- LEACHING RECHARGE BASIN LRB -5 F.G. 10.80 -- LEACHING RECHARGE BASIN LRB -6 F.G. 10.80 -- LEACHING RECHARGE BASIN *F.G. REPRESENTS FINISH GRADE I 4" LAYER OF LOAM (ROLLED AND SEEDED WITH WSM)— SHOULDERS AND SIDE SLOPES—BOTH SIDES PITCH UNITS TO BE COVERED FILTER FABRIC1' x 2" x 4' WOODEN MIRAFI 140 NC FILTER FABRI STAPLE FABRIC STAKE 6' ON CENTER INTERFACE PRIOR TO BACKFILL M POST. CULTEC N CONTACTOR MIRAFI 600X GEOTEXTILE' 2'-0" SLOPE 2'-0' 10OHD a _ _ tom!.' O O t O t l , () O O ' O o f" ( ii BURY BOTTOM OF r, { c.1 FILTER FABRIC IN = 6' x 6" TRENCH _ ;t JJ �4,vn t:t tr C., Cr" Cryf't?�rr� (; C ( ,-. r F i t) i'1 n - r `� t ` ',.`. r J 6" STONE BASE 3/4" - 1 1/2" DOUBLE 36` (TYP.) WASHED CRUSHED STONE SILT FENCE DETAIL NOT TO SCALE z IERI PITCH SHOULDER 2% MIN. PITS ' ' SHS OULDER ' 2 1 MAX. .. °'; .. 3 1 1 MAX.. ' 111- _I 11=1111 1 III 1" FINISH COURSE, TYPE 1-1 BIT. CONC. 2' BINDER COURSE, TYPE 1-1 BIT. CONC. 12" PROCESSED GRAVEL BASE COURSE (COMPACTED 95% DRY DENSITY AASHTO TEST METHOD C) (MASS. SPEC. M1.03.1) GRANULAR SUB BASE TYPICAL SECTION THROUGH PROPOSED ACCESS DRIVEWAY NOT TO SCALE TWO (2) 24- SQUARE CAST IRON FRAME & GRATES (64 OPENINGS 0 2-1/4" SQUARE PER GRATE) MAX,2 1 6" STONE - M2.02.4 MASS ADJUST FRAME & GRATES TO KNISH GRADE WITH r -DPW SID. SPECS. BRICK COURSES AS REQUIRED U N W 6- DIA HDPE PIPE (SEE PLAN FOR NUMBER OF OUTLETS) j TOP SLAB ;�.A. PRECAST REINFORCED CONCRETE BASIN FACTORY WATERPROOFED BUM JOINT SEALANT TOTAL WIDTH OF WALL AND PIPE OPENINGS (TYP) CTENDED BASE SEE NOTE 2 PRECAST CONCRETE DOUBLE GRATE CATCH BASIN NOT TO SCALE GENERAL NOTF_S: 1) ALL REINFORCING STEEL MUST CONFORM TO THE LATEST ASTM A185 AND/OR A615 GRADE 60. SEE TABLET FOR STEEL REINFORCEMENT REQUIREMENT. 2) STEEL REINFORCEMENT FOR BASE SECTION BOTTOM SHALL BE A MIN. OF 0.12 SQ. IN/LINEAL FT. (BOTH WAYS) 3) CATCH BASIN SPECS. CONFORM TO THE LATEST ASTM C478 SPEC. FOR "PRECAST REINFORCED CONCRETE MANHOLE SECTIONS". 4) MORTAR SHALL CONFORM TO SECTION M4.02.15 OF THE MASSACHUSETTS D.P.W. STANDARD SPECS. FOR HIGHWAYS AND BRIDGES. 5) PIPE TO CATCH BASIN CONNECTIONS SHALL BE MADE WITH NON—SHRINK GROUT OR HYDRAULIC CEMENT. ONE POUR MONOLITHIC BASE SECTION. 6) ANY NECESSARY ADJUSTMENTS DURING CONSTRUCTION WILL BE DONE BY SAW—CUTTING AND/OR CORING ONLY. NO JACKHAMMERS, HAMMERS, CHISELS OR PNEUMATIC TOOLS WILL BE ALLOWED. 7) RED CLAY BRICK SHALL CONFORM WITH SECTION M4.05.2 CLAY BRICK OF MASSACHUSETTS D.P.W. STANDARD SPECS. FOR HIGHWAY AND BRIDGES. 8) FILTER FABRIC SHALL BE SET UNDER CATCH BASIN GRATES TO PREVENT SILTATION TO THE BASINS UNTIL SITE HAS BEEN STABILIZED. CHAMBERS ARE TO BE LAID LEVEL TYPICAL SECTION - CONTACTOR 10OHD BED (NOT TO SCALE) ARROWS STAMPED ON UNITS MUST POINT TOWARD INLET. //NN//" "//" I 8" DIA HDPE PIPE 14' MIN. - 95% COMPACTED FILL 6" DIA HDPE PIPE _ _ _ o o e e e e��� e a o • e e e ��� e e o a • e e e e e I e e e e e e e e e e o o e e e a e e e e e LENGTH VARIES (SEE PLAN) FOR EACH TRENCH: USE THE FOLLOWING NOTE: CULTEC — MODEL CONTACTOR "CULTEC—MODEL CONTACTOR 10OHD" UNITS 10OHD UNITS SHALL BE INSTALLED 1 — 10OHD S (STARTER) IN STRICT COMPLIANCE WITH MFG I 10OHD INTERMEDIATE WRITTEN SPECIFICATIONS. 3 — (INTERMEDIATE) 1 — 10OHD E (END) TYPICAL SIDE VIEW — CONTACTOR 10OHD BED (NOT TO SCALE) B" DIA. HDPE FROM CATCH 6' DIA. HDPE PIPE' B' DIA. HDPE FROM CATCH 8' DIA MANIR -------- , r 5' SOIL REMOVAL NOTES: SEE PLAN FOR LENGTH DRAINAGE RECHARGE STRUCTURES TO BE PLACED IN CLEAN COARSE SAND. CONTRACTOR TO PERFORM A SOIL TEST AND NOTIFY ENGINEER FOR ON SITE INSPECTION OF SOILS PRIOR TO INSTALLATION OF ANY DRAINAGE SYSTEM i COMPONENTS. STRUCTURE MAY BE PLACED ABOVE COARSE SAND LAYER PROVIDED CONTRACTOR PERFORMS A 5' SOIL REMOVAL AROUND BASIN DOWN TO THE COARSE SAND HORIZON. REMOVAL TO BE FILLED IN ACCORDANCE WITH NOTE BELOW TO TOP OF STRUCTURE (CONTRACTOR SHALL INCLUDE A UNIT COST FOR REMOVAL AND REPLACEMENT IN THE BID PRICE). CULTEC STORMWATER RECHARGE CHAMBERS ARRANGED IN FIELD CONFIGURATION WITH ROWS OF CONTACTOR 10OHD UNITS. ROWS TO BE SPACED 4" APART WITH 2' OF z STONE ON THE ENDS AND 7 STONE ON THE SIDES (SEE PLAN FOR NUMBER OF ROWS a AND NUMBER OF CONTACTOR UNITS PER EACH CONFIGURATION) FILL MATERIAL FOR SYSTEMS CONSTRUCTED IN FILL SHALL BE CLEAN GRANULAR SAND, FREE OF ORGANIC MATTER AND OTHER DELETERIOUS MATERIALS. THE SAND SHALL BE GRADED SUCH THAT NOT MORE THAN 45% OF THE SAMPLE, BY WEIGHT, SHALL BE RETAINED ON THE #4 SIEVE. THE FILL SHALL NOT CONTAIN ANY MATERIAL LARGER THAN 2 INCHES. THE MATERIAL THAT PASSES THE J4 SIEVE SHALL MEET THE FOLLOWING GRADATION REQUIREMENTS: r ------------- 1, PORT '-------------------N -------------- TYPICAL PLAN VIEW — CONTACTOR 10OHD BED (NOT TO SCALE) FINISH GRADE 4 MIL POLY OVER A 4' LAYER! OF 1/8' TO 1/2" STONE 4' DIA. DRAIN PIPE 2' DIA PRECAST �i CONCRETE ` N DRYV01 10'-0" TYPICAL DRYWELL SIEVE PERCENT SIZE PASSING 4 4 100% IT 50 1107r100% 111 100 0%-20% A 200 0%-5% • 1[RON FRAME & COVER CULTEC COVER FINISH GROUND 8" CONCRETE COLLAR 6* INTERNAL6" PVC PIPE RISE!, ....e.�e.... 0NG COUPLI .•.e...e... ..•........, 1,z 7., ...e. 1 00e.........e.:. f .................L..... 1 .1. DOUBLED m r ••••�- ................ :-i �. - i STORMWATER RECHARGE BASIN DETAILS (NOT TO SCALE) INSPECTION PORT ;SUED FOR REGULATORY REVIEW 07/27/07 OASTAL NGINEERING OMMY, INC. 260 Cranberry Hwy. Orleans, MA 02653 508.255.6511 Fax: 508.255.6700 a A DAVID b Q V Q a0. a Q U Q O H o�A A a H U O � o9. v v� SCALE AS NOTED DRAWING FILE C16755.dwg DATE 7-27-07 DRAWNBY SMR 0 0 N d 02.4.1 OF 4 SHEETS o PROJECT NO. 016755.00 U