HomeMy WebLinkAbout83-1836 - Site PlanLEGEND SYSTEM DESIGN: - 99- EXISTING CONTOUR DATE: JULY < GARBAGE DISPOSER IS NOT ALLOWED 991 EXIST. SPOT ELEV. PERC. RATE 9:9 PROPOSED CONTOUR DESIGN FLOW: 4 BEDROOMS ® 110 GPD = 440 GPD 98.4] PROPOSED SPOT EL. USE A 440 GPD DESIGN FLOW TH1 SEPTIC TANK: 440 GPD (2) = 880 TEST HOLE ELEV. ELEV. \% USE A 2500 GAL. SEPTIC TANK/PC COMBO 2� SLOPE OF GROUND 28.3' LEACHING: CL, UTILITY POLE SIDES: 2 (41.5 + 10.25) 1.83 (.74) = 140 GPD FIRE HYDRANT = BOTTOM 41.5 x 10.25 (.74) 314 GPD NOT ALL SYMBOLS MAY APPEAR IN DRAWING TOTAL: 631 S.F. 454 GPD LS USE (5) H-20 3050 INFILTRATORS WITH 3' STONE AT ENDS AND 3' AT SIDES APPROVED PROP. FIRST FL AT EL MA DATE BOARD OF HEALTH BENCH MARK - HYDRANT ON TAG BOLT #1486 EL. = 31.25 ALL SYSTEM COMPONENTS SHALL BESYSTEM PROFILE KD MAGNETICAPE OR (NOT TO SCALE) COMPARABLE MEANS FOR FUTURE LOCATION. ACCESS COVERS TO WITHIN 6" OF FIN. GRADE PROVIDE INSPECTION PORT TO WITHIN 3" OF FINAL GRADE 23.1' MINIMUM .75' OF COVER OVER PRECAST 2% SLOPE REQUIRED OVER SYSTEM eOSCH40 PVC PROVIDE INLET PIPES LEVEL 1ST 2' rACUE L H-10 y TEE IN D'SOX ANK/ i BINATION ; . LEVEL CAS BAFFLE % °e °°o"ovoo°oo"oo°°o oa EQUAL ° :.°0°,°!0°02° o: (SEE TAIL BELOW) 95.97' 1 25.8' 4� ^scH�o pvc 000000a0000000000000000c n n n n n n n n r INVERT pE21.0'*•t _ 6" CRUSHED STONE OR MOUTry COMPACTION. (15.221 [21) 14" P PINE jp /A DI 4 tO / \ w` p TH 1 MIN. (1_0% SLOPE) (-!-% SLOPE) FOUNDATION - 14' -SEPTIC TANK PUMP 55' D' BOX 32' CHAMBER NOTE: WATERLINE MUST BE RE-ROUTED TO BE MIN. 10' FROM SEPTIC COMPONENTS IF RESERVE TO BE UTILIZED. 1�6 PWS wuNe 28 u. ^ N IV NCIV EXISTING CARD! DWEL />6• EXISTING DWELLING FIRST FLOOR = 31.0' P PROP. VENT (FINAL PLACEMENT NTH HOMEOWNER'S CONSULTATION).. PROPOSED DWELLING TOP FNDN. - EL 31.0' PROPOSED 2500 GAL SEPTIC / TANK/PUMP CHAMBER COMBINATION 2 "o 0 4 i PROp.DEC� / DECK// LAWN / �^ >s R /PE's 2" DOUBLE WASHED PEASTO OR GEOTEXII'I�E FABRIC 26.0' 23.5' (5) 3050 H-20 INFILTRATORS 3/4" TO 1 1/2" DOUBLE WASHED STONE OVERALL DIMENSIONS TO OUTSIDE OF STONE: 41.5' X 10.25' NP 9 $ 6� 3 LEACHING FACILITY BASS RIVER 17.3' BOTTOM TH-1 NO GROUNDWATER FOUND NOTES 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-19 5. PIPE JOINTS TO BE MADE WATERTIGHT. B. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE V.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 13. PROPOSED WORK LIMIT LINE TO CONSIST OF SILT FENCE &/OR HAYBALES, PER CONSERVATION AGENT DIRECTION. 14. ALL ROOF RUN-OFF TO BE DIRECTED TO DRYWELLS OR STONE TRENCHES. 15. CONTRACTOR TO VERIFY SUITABILITY AND FEASIBILITY OF EXISTING ELECTRICAL SYSTEM TO ACCOMMODATE PROPOSED SEPTIC PUMP SYSTEM PRIOR TO INSTALLATION OF ANY COMPONENT. ACCESS FOR ROUTINE MAINTENANCE MUST BE PROVIDED FOR ZABEL FILTER. INSTALLER MUST FOLLOW ALL MANUFACTURER'S SPECIFICATIONS FOR PROPER FILTER INSTALLATION NOTE: 5003 GAL RESERVE PROVIDED IN PC ALARM AND CONTROL PANEL INV. IN 23.1' TO BE INSTALLED INSIDE BUILDING. ALARM TO BE ON INV. IN 20.5' SEPARATE CIRCUIT FROM PUMP 2• PRESSURE UNE ZAFILTER 7e TEE SLOPE TO DRAIN BACK FLOAT SVATCH ALARM ON (Al(At 00) OUTLET 7EE W/EXTENSION WEEP HOLE SETTINGS: 1500 GAL MI . PUMP ON " THIS SIDE CHECK VALVE 5• WORKING RANGE 6OF BAFFLE MYEFS SRM 4 5• 5,8' SUBMERSIBLE 4 10 HP PUMP PUMP OFF 12 SYSTEN (OR EWAL) (ON BLOCK) 4 DOSES PER DAY, AT 110 GAL PER 000000 0000 00 0000 DOSE (5" WORKING RANGE) 5• e+FFLe 2500 GAL. SEPTIC TANK/PUMP CHAMBER COMBINATION (NOT TO SCALE) DANIELA.c OJALA � fTpz/�DANIEL' CIVIL �' OJALA No. 46502o.4098C DATE DANIEL A. OJALA, P.E., P.L.S. LOCUS MAP SCALE 1"=2000'± ASSESSORS MAP 70 PARCEL 79 LOCUS IS WITHIN FEMA FLOOD ZONE A7 EL 8 AND C AS SHOWN ON COMMUNITY PANEL 0250015 0004 C DATED JUNE 17, 1986 LOCUS IS NOT WITHIN APD (ZONE II) TEST HOLE LOGS ENGINEER: DAVID FLAHERTY, R.S., SE2755 WITNESS: AMY VON HONE, R.S., C.H.O. DATE: JULY 24, 2008 0 10 20 PERC. RATE _ < 2 MIN/INCH off 508-362-4541 CLASS I SOILS 4 ELEV. ELEV. \% 0" 28.8' 0„ 28.3' A 939 Main Street ( Rte 6A) YARMOUTHPORT A LS LS 10YR 3/2 10YR 3/2 10 10" B B LS LS 35' 1OYR 4/6 25 9, 30" 1OYR 4/6 25.8' C C PERC MS MS 2.5Y 6/4 2.5Y 6/4 120" I 118_8' 132" I 17_3' NO GROUNDWATER ENCOUNTERED OF 20 RIVER DRIVE SOUTH YARMOUTH, MA PREPARED FOR LEE & BARBARA TROUP JULY 25, 2008 REV. AUGUST 29, 2008 (CONS COMM) Scale:1 "= 20' 0 10 20 30 40 50 FEET off 508-362-4541 fox 508-362-9880 I downcppe.com down cape engineering, Inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675