Loading...
HomeMy WebLinkAboutEngineered Plan - 2015LEGEND 99 - EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. 99 PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 SIDE SETBACK 15' TEST HOLE 2% SLOPE OF GROUND MAX. UTILITY POLE 35' FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM J T I r_- 1V1 VIC%7I%.;IIM. GARBAGE DISPOSER IS NOT ALLOWED I. DESIGN FLOW: 4 BEDROOMS @ 110 GPD 440 GPD USE A 440 GPD DESIGN FLOW l SEPTIC TANK: 440 GPD (2) = 880 USE A 1500 GAL. H-10 SEPTIC TANK LEACHING: 440 GPD / (.74) = 595 SF REQUIRED c 15'X40'=600 SF OK 600 SF X .74 = 444 GPD OK USE A 15' X 40' PIPE AND STONE LEACHING FIELD i I I i MA APPROVED DATE BOARD PPF HEALTH BENCHMARK: I MAG NAIL ELEVATION I =8.65 NAVD88 MAP 17 PARCEL 79 5' REMOVAL OF UNSUITABLE SOIL REQUIRED AROUND PERIMETER OF LEACHING, FACILITY, DOWN TO SUITABLE SOIL LAYER. REPLACE WITH CLEAN MED. SAND, TO MEET SPECIFICATIONS OF 310 CMR 15.255(3 MAP 17 PARCEL 69 REDEVELOPMENT IN RIVERFRONT MITIGATION CALCULATIONS EXISTING HARDSCAPE = 2,189 SF PROPOSED HARDSCAPE = 3,755 SF NET INCREASE IN HARDSCAPE = 1,566 SF REQUIRED MITIGATION (1566 x 2) = 3.132 SF 3135 SF PROVIDED OK 4--329 PROPOSED WATER LINE TO BE SLEEVED WITHIN 10' OF AND PROPOSED SEPTIC COMPONENTS / PROVIDE MIN. 20" DIAM. WATERTIGHT 5 Y 5 I CM F0KUI-ILL ACCESS COVERS TO WITHIN 6" OF FIN. GRADE (NOT TO SCALE) FIRST FL 1 ELEV. 13.5' MINIMUM .75' OF COVER OVER PRECAST 2" PEASTONE OR GEOTEXTILE TOP FNDN. EL 12.5' 1 1.8 FILTER FABRIC OVER STONE ALL 5TS I tM 4UMNUNLN 15 tiNALL tit MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION. 70f 2% SLOPE REQUIRED OVER SYSTEM L10.1 NOTE. 2" MIN. WALL PROVIDE INSPECTION PORT TO V PRECAST H-10 THICKNESS REQUIRED RISERS (TYP.) 4"�SCH401 PVC .: 4'SCH40 PVC 2'0 " ::•. PIPES LEVEL 1ST 2' 2 DOUBLE -WASHED PEASTON 4"NSCH80 PVC OR GEOTEXTILE FABRIC * 10.23' 9.28 r r 10" 1500 GAL H-10 TEE y r RAWL SLAB 9.5'1 9.85 TEE SEPTIC TANK 9'6 0 0 0 0 0 0 r °°o°o°o°°o°o°°o°°o°°oo°o°o°o°o°°o°o°°o°o°o°°o°°o°°o° _o°o°o'o°Oo°o°o° 4' LIQ. LEVEL o°o°o°o°o°o° 8,79 ACME OR EQUAL GAS BAFFLE +°o�°o,°o°o°,o° ;a:: 8.99' 8.82' 1 1 00000° opo°o°o�o�o�o�a°a�o�o�o�a�o�o°o'o°opo 0000000000000000000000. WATER TEST I'BOXFORLEVELNESS +ono 0_0_0_n_1 ')00 0 0 0 0 o_r _�_0_n_n.o 0 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [2]) I (2-% SLOPE) (--L% % SLOPE) (-!-% SLOPE) FOUNDATION 19' SEPTIC TANK 61' D' BOX 5' 4"OSCH80 PVC i F,p RETAINING WALL MAP 17 PARCEL 89 PROPOSED ROOF DRYWELL 2' x 4' (TYP) EXISTING /HOUSE (DEMO) LOT 19 / 36,9901 SF PER REC..' PLAN/ i W � 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4" PVC SET AT .005'/' SLOPE ON 6" DOUBLE WASHED 3/4"- 1 1/2" STONE LEACHING FACILITY 3" OF FINAL GRADE 5' USE OBS. G -W ELEV. AT 3.1' (NOTE: TIDALLY INFLUENCED) ZONING SUMMARY ZONING DISTRICT: R25 DISTRICT NOTES j 1. DATUM IS NAVD88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8- PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-19 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED 5' BENEATH AND AROUND THE PROPOSED LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. 13. POOL FENCE SHALL HAVE SELF-CLOSING SELF -LATCHING GATES, SIZE AND MATERIALS TO MEET LOCAL AND STATE BUILDING CODE, ALL DWELLING DOORS OPENING TO POOL SHALL BE ALARMED TO CODE. 14. FLOOD RESISTANT FOUNDATION DESIGN BY OTHERS. 15. PATIO & ROOF RUNOFF TO BE DIRECTED TO DRYWELLS AS SHOWN. MIN. LOT SIZE 25,000 S.F. MIN. FRONTAGE 150' MIN. FRONT SETBACK 30' MIN. SIDE SETBACK 15' MIN. REAR SETBACK 20' MAX. BUILDING HEIGHT 35' MAX. BUILDING COVERAGE 25% SITE IS NOT LOCATED WITHIN APD OWNER OF RECORD LOCUS MAP NOT TO SCALE ASSESSORS MAP 17 PARCEL 68 LOCUS IS WITHIN FEMA FLOOD ZONE AE EL. 12, AE EL. 11 (HOUSE AREA) & VE EL. 13 AS SHOWN ON PANEL 25001 C0588J EFF, 7/16/14 TEST HOLE LOGS ENGINEER: DANIEL E. GONSALVES, SE #13587 WITNESS: AMY VON HONE, RS DATE: 12/17/14 PERC. RATE _ < 2 MIN/INCH CLASS I SOILS 4 ELEV. 0" 9.4' Orr A A LS LS 10YR 2/2 10YR 2/2 B_ B LS LS 10YR 5/6 10YR 5/6 C C M/CS M/CS 3.0' 75" OBS. WATER OBS. WATER 10YR 6/8 10YR 6/8 FRANCIS POLI 16" 404 PINE CREEK AVENUE FAIRFIELD, CT 06824 33' REFERENCES PERC 40 DEED BOOK 26479 PAGE 52 PLAN BOOK 56 PAGE 9 MONITORING WELL READING TABLE /G� 77� r=E-12) i DATE GROUNDWATER TIDE DATE GROUNDWATER TIDE �'>w�r:ta I�LEa ��prr9t>��nt 108" PPTII�GVEEV 18" 6.8' 39" 0.5' 120" ELEV. 9.3' 6.4' 3.1' -0.5' y, R„"lio.nrill it+l ��:.,I I OF 57 LEWIS BAY ROAD WEST YARMOUTH, M A PREPARED FOR JUL 2 d 2015 HEALTH DEPT. 6'/0 �r DATE DANIEL A. OJALA, P.E., P.L.S. FRANCIS POLI DATE: MARCH 18, 2015 Scale:1 "= 20' 0 10 20 30 40 50 FEET off 508-362-4541 I fax 508-362-9880 downcape.com down capeengineering, inc. civil engineers land surveyors 939 Main Street ( Rte 6A) YARIWOUTHPORT MA 02675 14-329 POLI.DWG