HomeMy WebLinkAboutEngineered Plans - Rev. 2016vw tw urw
M/'1/MUM FEASS E00MMANCES
1) NAM CE 11 -EW l:EiidAGKt EPMaNIHEEDOFOMEW
AND LOCLOrS REST A S# SEMM18Ft MCM
A60 NFRANCEIMMSM 8i0C IORSAD5('t)(9)
2) 1ARWICE7 IHE2(rSE'18KCBErY MlHEWMOFWEW
ANDEXOr BLALDWI A Uff EEMC raPFCMDH7.
A60 WRANCESFEMOM 31OCMR154O5(1X8)
I 1A
M
wofTopSh
EL= 50.0
�Re Z bion
Tr doft
(4.+)
Lot 6
8,150* S4. R.
House #42
't.MEL=49.5
tl fl e
Pootatte (+s�
adrav
Dt3
•
Yarmouth, MA
Bad
Bad #2
#1 Old lutein Street
1MIbw crest them Street
Dng Bath
in ng Wf
�1eCt Loals
(4"
CO
("
cC� 1'
IticTank
Aamain
(VIP)
(49,4)
lj
a
It -
(W)
Permit valid for REPAIR OF ETTIC SYSTEM
ONLY; due to State and I oc;rl septic variances.
Board of Health.review and approval is required for
any, future additions/rewj%'aiionsi:ilterations to
sewage faei(ities and/or structur esu/dwrUing.
Yarmouth fleattr De-paRinent
APPRUV 5e�&J4
Date
f
Boor Plan
N TSS
•u
"rWr
14MiliclAw
W
9—M-16
AUG 19 20106
HEALTH DEPT
`! )Aee wofsMSp 42 Peace! 252
2) Book 26M Fbp 344
3.) Ran Book 98 fte 35
4.) Ws property isnot in aZone )) Public
VU*eqwpply.
6.) This p#*wty isin Hood inane Xasshmn on
Map 2$OtNC0 W Date 7/16114
(482) DOING SPOT G*DE
FAUNMEWOTGRAM
—24— CONTOUR
ohw— OVEMISADU 1UTYUNEE
u--- UNDSOMND UTIL17YUNES
G C-ASSi AC EUNE
....� . �.� EDGEOFCLEARNG
FENCE
TwHOLELOCA m
Sr S FMIANK
Mom E Scic hilone
S c h Ywnoutfi, MA
All Cie Septics
618 haute 28
ftmd Yarmouth, MA 42673
(508) 77IA200 r:meil:allcapeseptic@gmaii.com
oete: OB/MIG I :;fleet 1 cf 2 JWMA 00* 34 1N0.AO71
Dete:06/WIG OMMChtberDeeign
TOP OF FOUNDATION MkWM2r01AWrERC0N0AM
covERSRaloMnnaes'c>F Riser Extension Proposed Riser Extension
EL = 49.8 F res (DRASNORD) to within 6" of grade D -BOX ELr 4$9i to within W of grade
r�r"MUMvoFca� MINIMUM 9" OF COVER
�P GfOTEXTILE FABRIC
'� 47 5 46.1 �n - 3f:4 m (iN PLACE OF 1/4"-1/2" PEASTONE)
.�.� 47.3
INVERTEL INYERTEL to"
-
45.9 45.73
Depth
Elev.
Existin 14
gTO Remain INSTALLTFEAND GAS BAFFLF ATOULlET
INVERTEL 45.6
-
1-1/2"STONE
(Double
011-81'
6• s1aNE aASE
A
wash)
1 OYR 3/1
DB -3
-
46.9
B
H-20 RatedH-20
Rated
32"-150"
'6
THREE (3) SHOREY PRECAST CONCRETE
Fine Sand
Existing 1,000 Gal
LEACH CHAMBERS (4'X 8! X IW DEEP)
l 25t --i Septic Tank
f 1 r r
! YVITFi 4` STONE ONTHE SIDES AND ENDS
s
To Remain
1 r
Longest Run ^(
LEACH CHAMBERS
EL=39.2Adjusted Ground Water
FLOW PROFILE
(ENDVIEW)
EL= 37.1 Observed Ground Water
CONSTRUCTION NOTES
NOTTO SCALE
EL= 37-1 Bottom Test Hole
1 J ALL WORK SHALLCONFORM TO THE STATE ENVRONMENTALCODE,TITLE5 (310CMR IS:DDW.
STANDARD REQUIREMENTS FOR THE SITING, CONSTRUCTIOK INSIWTION, UPGRADE, AND
EXPANSION OF ON-SITE5EWAGETREMMENT AND DISPOSAL SYSTEMS AND FOR THETRANSP'ORT
AND DISPOSAL OF SEPTAGE, ANDTHE LOCAL BOARD OF HEALTH REGULATIONS.
2J ANY SEPTIC SYSTEM COMPONENT INSTALLED IN A LOCA71ON WHFRETHERE IS POTEMTIAL FOR
VEHICLES OR HEAVY EQUIPMENTTO PASS OVER IT SHALL BE DESIGNED TOWrIN5TANDANH-20
LOADING. IF UNDER AN IMPERVIOUS SURFACE, SYSTEM SHALL BE VENTEDTO THE ATMOSPHERE.
3.) TO MINIMIZE UNEVEN SETTLING, SEP ICTANKS AND D -BOX SHALL BE INSTALLED ON A STABLE
MECHANICALLY -COMPACTED BASE ON SIX INCHES OF CRUSHED STONE.
4.) COVERS OVER THE INLET AND OUTLETTEESOFTHESEP ICTANK,THEDWRIBUTION Bol(, AND
THE SOIL ABSORPTION SYSTEM SHALL BE RALSEDTOWTTHINB`OF FINALGRADE LEAGIING
FIELDS, TRENCHES, AND OTHER SOIL ABSORPTION SYSTEMSWITHOUT ACCESS MANHOLES SHALL
HAVE AT LEAST ONE (1) INSPECTION PORT CONSISTING OF PERFORATED 4" PVC PIPE PLACED
VERTICALLYTO THE BOTTOM OF THE SOIL ABSORPTION SYSTEM WITH ACAP TIED WITH MAGNETIC
MARK] NGTAPE, ACCESSIBLE TO WITHIN 3" OF FINAL GRADE
5.) PIPING SHALL CONSIST OF 4" SCHEDULE 40 PVC OR EQUIVALENT. PIPE SHALL BE LAID ON A
MINIMUM CONTINUOUS GRADE OF NOT LESS THAN 2% FROM THE BUILDING TO THE SEPTIC TANK
AND NOT LESSTHAN I% OTHERWISE.
6) DISTRIBUTION LINES FOR THE SOIL ABSORPTION SYSTEM SHALL BE 4" DIAMETER SCHEDULE 40
PVC (OR EQUIVALENT) LAID AT O.OD5 FTIFT. UNLESS OTHERWISE NOTED. LINES SHALL BE CAPPED
AT END OR AS NOTED.
7J LINES FROM THE DISTRIBUTION BOX TO BE LEVEL FOR THE FIRSTTWO (2) FEET BEFORE
PITCHING TO THE SOIL ABSORPTION SYSTEM. DISTRIBUTION BOX SHALL BE WATIRTESTEDTO
ASSURE EVEN DISTRIBUTION,
84 GROUTTO BE USED AT ALL POINTS WHERE PIPES ENTER OR LEAVE ALL CONCRETE STRUCTURES
IN ORDER TO PROVIDE A WATERTIGHT SEAL.
9J HEAVY EQUIPMENT SHALL NOT BE ALLOWED TO OPERATE OVERTHE LIMITS OF THE SEWAGE
DISPOSAL FIELD DURING THE COURSE OF CONSTRUCTION OF THE SYSTEM.
10.) IN ACCORDANCE WITH 310 CMR 15.221, ALL SYSTEM COMPONENTS SHALL BE MARKED WITH
MAGNETIC MARKING TAPE.
11.) THERE ARE NO KNOWN WELLS WITHIN 100' OF THE PROPOSED SOIL ABSORPTION SYSTEM.
12.) FROM THE DATE OF THE INSTALLATION OF THE SOIL ABSORPTION SYSTEM UNTIL RECEIPT OF
THE CERTIFICATE OF COMPLIANCE, THE PERIMETER SHALL BE STAKED AND FLAGGED TO PREVENT
USE OF THE AREATHAT MAY CAUSE DAMAGE TO THE SYSTEM.
13.) THE DESIGNER WILL NOT BE RESPONSIBLE FOR THE SYSTEM AS DESIGNED UNLESS
CONSTRUCTED AS SHOWN ON PLAN. ANY CHANGES SHALL BE APPROVED IN WRITING BY THE
DESIGNER.
14.)THE BOARD OF HEALTH REQUIRES INSPECTION OF ALL CONSTRUCTION BY AN AGENT OF THE
BOARD OF HEALTH AND THE DESIGNER. THE DESIGNER SHALL CERTIFY IN WRITING THATTHE
SEWAGE DISPOSAL SYSTEM WAS INSTALLED IN ACCORDANCE WITH THE TERMS OFTHE PERMIT
ANDTHE APPROVED PLANS. 48 HOURS ADVANCE NOTICE IS REQUESTED.
15.) LOCATION OF UTILITIES IS APPROXIMATE AND CONTRACTOR SHALL BE RESPONSIBLE FOR
DETERMINING THE LOCATION OF ALL UNDERGROUND AND OVERHEAD UTILITIES PRIOR TO
COMMENCEMENT OF ANY WORK. THIS INCLUDES, BUT IS NOT LIMITED TO, REQUESTS TO DIGSAFE,
ANY PRIVATE UTILITY COMPANIES, ANDTHE LOCAL WATER DEPARTMENT,
16) CONTRACTOR SHALLVERIFY THAT ALL WASTELINIS ARE CONNECTED BY WATER TESTING
WITHIN THE DWELLING PRIOR TO INSTALLATION OF ANY SEPTIC COMPONENTS,
17.) CONTRACTOR SHALL VERIFY EXISTING INVERT ELEVATIONS PRIOR TO INSTALLATION OF ANY
SEPTIC SYSTEM COMPONENTS.
18.) TEST HOLES COMPLETED PER STATE ENVIRONMENTAL CODE TITLE 5. SOILS CAN BE
VARIABLE AND TEST HOLE DATA IS NO GUARANTEE OF SOIL CONDITIONS IN OTHER AREAS. IF
SOILS DIFFER FROM THOSE SHOWN IN THE SOILS LOGS, DESIGN ENGINEER IS TO INSPECTTHE
SOILS PRIOR TO PROCEEDING WITH INSTALLATION OF ANY SEPTIC COMPONENTS.
19.) EXISTING SEPTIC COMPONENTS TO BE LOCATED, PUMPED DRY, FILLED WITH CLEAN SAND AND
ABANDONED IN PLACE OR REMOVED AS REQUIRED. AREA TO BE COMPACTED TO MINIMIZE SETTLING.
20.) WATERISEWER CROSSING: 2" PVC WASTEUNE SHALL BE SLEEVED IN A 20' SECTION OF
4" PVC PIPE CENTERED OVER THE WATER LINE TO MAXIMIZE DISTANCE TO JOINTS.
Yf N
D -Box
SYSTEM DESIGN CALCULATIONS
SEWAGE DESIGN FLOW REQUIRED: 2 BEDROOM DWELLING @ 110 GPD I BEDROOM = 220 GPD
REQUIRED
SEWAGE DESIGN FLOW PROVIDED: THREE (3) CONCRETE LEACH CHAMBERS {4' X 8' X 1' DEEP)
WITH 4' STONE ONTHE ENDS AND 4` STONE ON THE SIDES
Vt =1(32.0 x 12.0) +2(32.0+ 12.0) x-74 = 344 GPD PROVIDED
N 349 GPD PROVIDED > 220 GPD REQUIRED
SEPTIC TANK CAPACITY REQUIRED: 330 GPD X 200% = 660 GPD REQUIRED
° SEPTICTANKCAPACITY PROVIDED: 1,000 GALLON PROVIDED (EXISTING)
A GARBAGE DISPOSAL IS NOT PERMITTED WITH THIS DESIGN FLOW
Test Hole #1 (EL=49.6±)
Ica 1 n V LC LV V
Depth
Elev.
Layer
Soil Class
Soil Color
Comments
011-81'
49.0
A
Loamy Sand
1 OYR 3/1
81f- 32"
46.9
B
Loamy Sand
1 OYR5/6
32"-150"
37.1
C
Fine Sand
2,5Y6/3
I
Standing Groundwater Encountered @ 150" Depth EL = 37.1
DATE OF TESTING: 8/03/16
SOIL EVALUATOR: SCOTT MCGANN
BOARD OF HEALTH AGENT: AMYVON HONE
PERCOLATION RATE: LESS THAN 2 MINANCH IN "C" LAYER AT 59"
GROUNDWATER ENCOUNTERED AT 150" DEPTH EL = 37.1
Estimated High Groundwater Calculation
Index Well # MiW - 29 Zone A
OF
Date of Reading 7/16%'`
Depth to Groundwater 12.5
Groundwater Adjustment 2.1
Actual Groundwater Level 10.4U jVP
Estimated High Groundwater 39.2
Assessors Map 42 Parcel 252
Proposed Sewage Disposal System
42 Locust Street South Yarmouth, MA
Prepared for: Prepared by:
All Cape Septic LLC
Daren E. Scichilone 618 Route 28
South Yarmouth, MA West Yarmouth, MA 02673
(508) 771-4200
allcapeseptic@gmail.com
Date: 08/08/16 1 Sheet 2 of 2
6