HomeMy WebLinkAbout2013 Apr 19 - Sign Off Transmittal Sheet, Plan - Garage Addition �. .r..�,-,�.. �,:,,.�,m:-n�-,-��.�. �...�.���— - _ . ,.e.._ _�-�.�..�.�. �_.�.�.A����,,,,�.
o� '�a�e TUWN OF YARMOUTH
�'� � " �c
'� HEALTH DEPARTMENT
o;_,_ - ,
Y`"�-��-`%�� PERMIT APPLICATION SIGN OFF T1tANSMITTAL SHEET
To be completed by Applicant:
(� �
Building Site Location: �-''�t[^kn�� � ���-�.
J
Proposed Improvement: � u-�0.U�Q �i �,(,�.� � c o t/�
Applicant: Mo`���vsZ..Lv �.... C.�n���(�� Tel.No.: Sa���q��S Z yZ
Address: U (�� (�-�� �D�-(�--Q- � .!v�- .�-�``� Date Filed: ` � � 13
**If you would like e-mai!notification of sign o,f�J;pdease provide e-mail address: '
Owner Name: �!'.`.�� 1t-�-� � �..-��•l�S
Owner Address: �-'` (� ,r-G(,�.°,� �,,,,��,,,SZ Owner Tel.No.: c, b'g-�1`�� '3 Z�l"Z.
.............................................:.............:..................................................................:............................................................................................................:.............:..:..........................:............................................:.............................�
�
RESIDENTIAL AND/OR COMMERCIAL BUILDING
HEALTH DEPARTMENT: Determines Compliance to State and Town Regulations; i.e.,Requirements ,
,
For Septage Disposal and other Public Healtli Activities. �
i
� � �`�Ye�se�submit�three��{3) copies of plans, to include:� � ��� � � i
(1.) Site P�an showing existing buildings,water line location, �
and septic system location;
(Z.) Floor plan tabeling ALL rooms within building
(all existing and proposed) -
Note:Floor plans not required for decks,sheds, windows,roofing;
(3.) If neeessary, Title 5 application signed by lic�nsed installer
with fee.
................................................................................................................................................................................................................................................................................:.......................................................................................
�,
REVIEWED BY: �J C.� DATE: '���"/_�
PLEASE NOTE
COMMENTS/CONDITIONS: � /,�
�
� l�G��l� 1`'�a � �
I
E
ANDERSEN
AW31
ANDERSEN
AW31
CONC.
APRON
ANDERSEN
AW31
9'0" x 9'9' O.H. DOOR
2'-O"
NEW
GARAGE
(5' CONC. SLAB W/ 6 x 6
WWF, PITCH 2" TO
O.H. DOORS)
24'-9'
14'-0"
6'-0" L 4'-0" 1� 6'-2" Ll 3'-10"
B
ANDERSEN A5
AW31
�? ANDERSEN ANDERSEN
N TW1836 TW1836
STEP DN. 1 2'8" x
6" TO SLAB FIRE
RATED
VERIFY HEIGHT FROM
EXIST. FIRST FLOOR
TO GARAGE SLAB &
DETERMINE RISER
HT. & QTY.
E'
9'0" x 9'0" O.H. DOOR
V-0"
ANDERSEN
J FWG6068L
NEW
4 LAUNDRY
b
5'0" x 6'9' I I b
DN. GLIDING / i -
DOORS
CLOS.
Y�
F �c�
01 1 NEW
HALL
1 MI' -JI
REMOD.
ED
II
HALL
o II 1
M I I
FIRST FLOOR PLAN_
COTUIT BAY DESIGN, LLC
43 BREWSTER ROAD
MAS H P E E , MA. 02649
PH. (508 274-1166
FAX 5081539-9402
EXIST.
BEDROOM
11 2':19' LEGEND:
EXISTING WALLS
L__J CONSTRUCTION TO BE REMOVED
,,,, NEW CONSTRUCTION
Q SMOKE DETECTOR
fl CARBON MONOXIDE DETECTOR
® HEAT DETECTOR
NEW ADDITION/REMODELING FOR:
CHILDS RESIDENCE
4 ORCHID LANE WEST YARMOUTH, MA
NOTES:
1.) CONTRACTOR IS TO VERIFY ALL EXISTING CONDITIONS
& DIMENSIONS IN THE FIELD
2.) CONTRACTOR TO VERIFY ALL INTERIOR & EXTERIOR MATERIALS,
DETAILS, & FINISHES IN THE FIELD WITH OWNER -
3.) ROUGH OPENING HEAD HEIGHT OF WINDOWS AT
FIRST FLOOR TO BE 6'-8" ABOVE SUBFLOOR
4.) ALL CONSTRUCTION TO CONFORM TO 780 CMR MASSACHUSETTS
STATE BUILDING CODE, 8TH EDITION AMENDEMENT & IRC2009
5.) 110 MPH EXPOSURE B WIND ZONE, 1.25 ASPECT RATIO
6.) ALL SHEETS OF PLYWOOD WALL SHEATHING TO BE INSTALLED VERTICALLY,
OR HORIZONTALLY W/ BLOCKING AT EDGES, 6"EDGE/12" FIELD NAILING
7.) ALL LVL LUMBER/BEAMS TO BE 1.9e U480 LOAD
8.) FOLLOW ALL MANUFACTURER'S SPECIFICATIONS FOR INSTALLATION OF ALL
SIMPSON COMPONENTS.
9.) ALL CONCRETE USED FOR FOUNDATION WALLS, FOOTINGS & SLABS
TO BE 3000 PSI
10.) VERIFY ALL PLUMBING & ELECTRICAL DETAILS W/ OWNERS ON THE SITE
DURING FRAMING CONSTRUCTION
11.) TIMBER FRAMING TO BE SPRUCE/PINE/FIR NO.2 GRADE
12.) ALL AZEK TRIM TO BE PAINTED WHITE & ALL JOINTS/NAIL HOLES SEALED.
13.) FOLLOW ALL REQUIREMENTS OF THE IECC2009 RESIDENTIAL ENERGY
EFFICIENCY REQUIREMENTS & VERIFY ALL DETAILS WITH THE INSULATION
INSTALLER/CONTRACTOR
14.) ALL MULTI LVL BEAMS, RIDGEBEAMS, ETC. TO BE SIZED BY THE
LUMBER SUPPLIER OR A STRUCTURAL ENGINEER.
IECC2009 RESIDENTIAL ENERGY EFFICIENCY DETAILS
CLIMATE ZONE 5A (USE EITHER PRESCRIPTIVE VALUES OR RESCHECK CALCULATION
TABLE 402.1.1 (MINIMUM PRESCRIPTIVE INSULATION & FENESTRATION REQUIREMENTS)
FENESTRATION
U -FACTOR
SKYLIGHT
LI -FACTOR
CEILING
R -VALUE
WOOD FRAMED WALL
R -VALUE
FLOOR
R -VALUE
BASEMENT WALL
R -VALUE
BASEMENT SLAB
R -VALUE
CRAWL SPACE WALL
R -VALUE
0.35
0.60
38
20
30
10/13
10 (2 FT. DEEP)
10/13
NOTES:
T. R -VALUES ARE MINIMUMS & U=FACTORS ARE MAXIMUMS—.
2.10/13 MEANS R=15 CONTINUOUS INSULATED SHEATHING ON THE INTERIOR OR EXTERIOR
OF THE HOME OR R=13 CAVITY INSULATION AT THE INTERIOR OF THE BASEMENT WALL
3. REFER TO IECC 2009 CHAPTER 4 FOR ALL INSULATION & ENERGY REQUIREMENTS
YzIrracuth Hen- a Department
WED
J�®Q
wee Dat e
THE DESIGNER SHALL BE NOTIFIED IF ANY
ERRORS OR OMISSIONS ARE FOUND ON
SCALE:
THESE DRAWINGS PRIOR TO START OF
THE BUILDING CONTRACTOR
CONWILL
1 /4" = 1
BE RESPONSIBLE FOR THE CCONTEENTRUCTION.
-0"
IN THESE DRAWINGS IF CONSTRUCTION
COMMENCES WITHOUT NOTIFYING THE
DESIGNER OF ANY ERRORS OR OMISSIONS.
THESE DRAWINGS ARE SOLELY FOR THE USE
DATE
OF THE OWNER NOTED. ANY OTHER USE OF
THESE DRAWINGS REQUIRES THE WRITTEN
CONSENT OF THE DESIGNER UNDER THE
4/12/2013
ARCHITECTURAL COPYRIGHT PROTECTION
ACT OF 1990.
DRAWING NO.: