Loading...
HomeMy WebLinkAboutEngineered Plan - 1996GENERAL NO TES THIN ACCESS COVERS MUST BE WITHIN, 6" OF FINISH GRADE 9' MINIMUM. I. THIS PLAN ISFORTHE DESIGN AND CONSTRUCTION 102.0 3' MAXIMUM COVER OF THE SEWAGE D 1 $POSAL SYSTEM ONLY. FI RST 2' TO - BE LEVEL MIN 2' OF PEASTONE 2. ALL CONSTRUCTION METHODS AND MATERIALS.AND 4' PVC -' MAINTENANCE OF THE SEPTIC SYSTEM SHALL - 3!4' - I 1/2' DIA. CONFORM TO MASS. D.E.P.:TITLE 5 AND LOCAL SCHEDULE 40 o Q s94.0 WASHED STONE BOARD OF HEALTH REGULATIONS, aAs 5 5 3-4'X 8' FLOWDIFFUSORS 96.0 BAFFLE OUTLET W/4 ' STONE AROUND. I2 'X 32 ' 3. ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER __ .v AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER l0' MIN. 1500 GAL D -BOX THAN 3` IN DEPTH SHALL BE CAPABLE OF W1TH- SEPTIC TANK 5' CRUSHED STONE BASE STANDING H-20 WHEEL LOADS. 4. -ALL SEWER PIPE SHALL .BE SCHEDULE 40 OR PROF I L E: NOT TO SCALE APPROVED EQUAL. 5. BEFORE CONSTRUCTION CALL 'DIG -SAFE'. 1-800-322-4844 AND THE LOCAL WATER DEPT. FOR LOCATION OF UNDERGROUND UTILITIES. 6. VERTICAL DATUM IS: ASSUMED 7. FOR BENCH MARKS SET. SEE SITE PLAN. 8. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEED RESTRICTIONS OR. ZONING REGULATIONS, IT SHALL REMAIN THE CLIENTS RESPONSIBILITY TO OBTAIN ALL PERMITS. SPECIAL PERMITS, ,VARIANCES ETC. FOR THIS PROJECT. loo. 3+ o0.3+ 9. IT SHALL REMAIN THE CLIENT'S RESPONSIBILITY 101,4+ ------------- ' TO HAVE THE PROPOSED BUILDING FOUNDATION DESIGNED TO ACCOUNT FOR THE EXISTING GRADE + Ior.i+ �� �.� 99.4+ AND SOIL CONDITIONS AT THE LOCATION OF THE 85'15'!0'�' PROPOSED BUILDING. 3-4'X 8• FLOWDIFFUSOR$ l0.' ALL UNSUITABLE MATERIAL (A d B HORIZONS) i� / � . �- i • • � � �� i� 7uo,s-} �� ' � - - --• -� '-" W/t • STONE AROUND i ENCOUNTERED BELOW THE INVERT OF THE LEACHING ror.oe / 100.e4. FACILITY. TO BE REMOVED FOR A DISTANCE' OF 5' -.._ AROUND _AND .,REPLACED, WITH_SAND-JN-ACCORDANCE_ // __ 99\��2 WITH T1 TLE 5. _ /may44 :- -� / --_ ------- 97;, / _ TP ---- i / 79 7.7+ 100.1+/ 98.7 £ PROPOSED SDR)7. // N ti O h 9716 --- / /�^1:. D-BOXr. TP -45't 3 O i 379. \\ PROPOSED THREEi� - --- � N i \\ BEDROOM OwFLLIN9- 9 SEPTIC TANK I / 97.7+ i i 22 O \i OF - 102.Q O 2 1 ( / / --- PROPOSED IN TER Sf VICE 5.0 WALKOUT ' 93,5+ 14� 44'1 A i 1� 100.0 93.4,+ FOLLINS POND 6\T 17. L 7 LOCUS i 3+� \` l \\ 17. 74\Q S . F . Ibe. l �� \ \\ 92. 893/5 I 1 1 \ + / ¢ i - e3 1 1 N 68.46'30'W 128.04' / 99. 94.70 y m PAVED DRIVE MEST v BENCH MARK r 1 - , 6R�T IrFS TFR PK NAIL IN ROAD EL -100.00 a �. ROUTE 6 { K WHITE'S PATH f b �' RAILRoA0 ~•�' l 4 ` �' f' � '/0 .. LOCUS AIIAP /� . • 20 ,'. 0 SOIL TEST PIT DA TA INDICATES INDICATES PERCOLATION OBSERVED TEST _ GROUNDWATER TP# I Tp • 2 GRND EL. 97.9 GRND EL. 96.8 G. W. EL. 85. 9 G. W. EL. NIA 0. MORIZON TEXTURE COLOR OTHER 97.9 0. HORIZON TEXTURE COLOR OTHER 96.8 O ! -'1 V 3 • ......... I97.73 ....................... ... .96.6 A LOAMY IOYR A LOAMY IOYR SAND 312 SAND 312 9 •,..............................................................� 97.2 7* . ............ .. _........................................ 96.2 OAMY IOYR - - LOAMY -` IOYR - B LSAND 414 •� B $AND 414 .............................................� ................... ............ 37' 94.8 22 --�• •• ••• ••• •••• 95.0 C / 1IEDlUM IOYR COBBLES I C / SANDY I0YR COMPACT SAND 714 GRA VEL L OAM 711 64 " (LOAMY) I 54 '...... ................:........... ........ 92.3 C2 MEDIUM IOYR COBBLES SAND 714 GRAVEL 68' 144" 85,9 150 *1 85.4 120" NO WATER 86.8 DATE: JULY J. 1996 TEST BY: STEPHEN HAAS WITNESSED BY: RON CADILLAC PERC RATE 2 MIN/INCH ' ����