Loading...
83-1857 - Site Plan006WALL & REMOVAL DETAILS SCALE: 1"=20' PROPOSED WALL 1' OFF LINE UNILOCK CONCORD OR ROMAN WALL PROPOSED TOP WALL=8.4 ADJACENT GRADE VARIES MAX. WALL HEIGHT=2' WALL MAY BE MADE HIGHER HERE ADJACENT TO SEPTIC TANK IF DESIRED. UNILOCK CONCORD OR ROMAN WALL PROPOSED TOP WALL=8.4 ADJACENT GRADE VARIES MAX. WALL HEIGHT=2'-8" PROPOSED TOP WALL=8.8 MIN. NEAR LEACHING AND TANKS WALL SECTION A -A AT MAXIMUM HEIGHT SCALE: 1"=2' COPING WALL 1' OFF PROPERTY LINE Exist. SYSTEM B --UNIT 123 BEDROOMS: GARBAGE GRINDER: REQUIRED CAPACITY: SEPTIC TANK: BOTTOM LEACHING ARI [(24' X 12')] — 1'/2 SIDE LEACHING AREA: [(71.3' PERIMETER) x DESIGN CAPACITY. [(287.3 SF + 17.8 s 2 No 220 GPD 1500 GAL. 287.3 SF 1.42 17.8 SF .25] 225 GPD X .74 GPD/SF] LEACH AREA USE 2 C-4 UNITS WITH 4' OF STONE ALL AROUND FOR A 24' X 12' X 3" DEEP LEACH AREA, MINUS A 1' X 17" TRIANGLE, AS SHOWN. RUN PERFOR— ATED PIPE DOWN CENTER OF C-4 UNITS BETWEEN HUMPS. CAPE END. BRING STONE TO TOP OF C-4 UNITS AND COVER WITH FILTER CLOTH. 2' MIN. REMOVAL WITH BARRIER DO ALL AROUND AND UNDER REMOVAL DOWN 37"t TO LOAMY SAND, AS SHOWN. v"8" X 6" 14" INTUNILOCK CONCORD OR ROMAN WALL ��BLOCKOCKING ro BLOCKS SITE PLAN PER MANUFACTURER SET EACH BLOCK BACK IMPERVIOUS BARRIER 3/4" TOWARDS RETAINED SOIL FOR AN / 40 MIL I �O� UNBALANCED SOIL HEIGHT UP TO 4 FEET.---_-- x GROUND VARIES FROM 5.7 TO 7.3 USE A MINIMUM OF ONE BLOCK COURSE BELOW GRADE COMPACTED GRANDULAR BASE 22" WIDE & 8" DEEP TITLE 5 SAND REV. 12/3/09 --EXTEND BLOCK WALL TO HOUSE, MOVE SEWER LINE REV. 5/01/09 --MONITORING WELL GRAPH, WALL HEIGHTS REV. 2/24/09 --REVISE TOP FOUND., SEPTIC, WALLS, MONITOR WELL, BENCHMARKS. REV. 9/02/08 --NO CHANGES ON THIS SHEET REV. 7/15/08 --PROPOSED FOOTPRINT, LOT COVERAGE & OFFSETS REV. 6/18/08--2 SEPTIC SYSTEMS & NEW OWNER REV. 5/30/08 --WALL CROSS SECTION REV. 5/29/08--C-4 UNITS REV. 5/23/08 --PRESBY SYSTEM HEALTH AGENT APPROVAL DATE JAMES G. MORRISON LOT 106 23 & 25 NEW HAMPSHIRE AVE, W. YARMOUTH, MA NOVEMBER 28, 2003 SCALE: 1"=20' RONALD J. CADILLAC, PLS, RS, P.C. PR FESSIONAL LAND SURVEYOR & REGISTERED SANITARIAN P.O. BOX 258 WEST YARMOUTH, MA 02673 (508) 775-9700 PAGE 2 OF 2 ©2008 BY R.J. CADILLAC CULTEC C-4 UNITS Prop. Top Block2 Invert 7.55 24' X 2' X 3' DEP AND BEDS Invert 8.00 Use Gas Baffle (See Detail) Proposed Proposed Invert 7.33 Use 10" Min. Cover REPLUMB H_ O Proposed Over Leaching S=1/8"/ft+ 7.71® Filter /8'55 min. I Prop 1500 sed Col. S=1/8"/ft Cloth_ _ S=1/8"/ft �/�� T� Invert 7.80 I Septic Tank Proposed 3" I Bottom 3.3 I Proposed Invert 7.50 7.0 Invert 7.25 5 I 6" Stone Or compact Proposed P I Level Bottom Proposed I C-4 Units I �181 7 �— 2' —� i N--8'--� EI. 2.0 m I 1.96—High Monitoring Well 0.6 m reading 2/09/09 (Full Moon) DESIGN DATA THt--Observed Water=11.4 BEDROOMS: GARBAGE GRINDER: REQUIRED CAPACITY: SEPTIC TANK: BOTTOM LEACHING ARI [(24' X 12')] — 1'/2 SIDE LEACHING AREA: [(71.3' PERIMETER) x DESIGN CAPACITY. [(287.3 SF + 17.8 s 2 No 220 GPD 1500 GAL. 287.3 SF 1.42 17.8 SF .25] 225 GPD X .74 GPD/SF] LEACH AREA USE 2 C-4 UNITS WITH 4' OF STONE ALL AROUND FOR A 24' X 12' X 3" DEEP LEACH AREA, MINUS A 1' X 17" TRIANGLE, AS SHOWN. RUN PERFOR— ATED PIPE DOWN CENTER OF C-4 UNITS BETWEEN HUMPS. CAPE END. BRING STONE TO TOP OF C-4 UNITS AND COVER WITH FILTER CLOTH. 2' MIN. REMOVAL WITH BARRIER DO ALL AROUND AND UNDER REMOVAL DOWN 37"t TO LOAMY SAND, AS SHOWN. v"8" X 6" 14" INTUNILOCK CONCORD OR ROMAN WALL ��BLOCKOCKING ro BLOCKS SITE PLAN PER MANUFACTURER SET EACH BLOCK BACK IMPERVIOUS BARRIER 3/4" TOWARDS RETAINED SOIL FOR AN / 40 MIL I �O� UNBALANCED SOIL HEIGHT UP TO 4 FEET.---_-- x GROUND VARIES FROM 5.7 TO 7.3 USE A MINIMUM OF ONE BLOCK COURSE BELOW GRADE COMPACTED GRANDULAR BASE 22" WIDE & 8" DEEP TITLE 5 SAND REV. 12/3/09 --EXTEND BLOCK WALL TO HOUSE, MOVE SEWER LINE REV. 5/01/09 --MONITORING WELL GRAPH, WALL HEIGHTS REV. 2/24/09 --REVISE TOP FOUND., SEPTIC, WALLS, MONITOR WELL, BENCHMARKS. REV. 9/02/08 --NO CHANGES ON THIS SHEET REV. 7/15/08 --PROPOSED FOOTPRINT, LOT COVERAGE & OFFSETS REV. 6/18/08--2 SEPTIC SYSTEMS & NEW OWNER REV. 5/30/08 --WALL CROSS SECTION REV. 5/29/08--C-4 UNITS REV. 5/23/08 --PRESBY SYSTEM HEALTH AGENT APPROVAL DATE JAMES G. MORRISON LOT 106 23 & 25 NEW HAMPSHIRE AVE, W. YARMOUTH, MA NOVEMBER 28, 2003 SCALE: 1"=20' RONALD J. CADILLAC, PLS, RS, P.C. PR FESSIONAL LAND SURVEYOR & REGISTERED SANITARIAN P.O. BOX 258 WEST YARMOUTH, MA 02673 (508) 775-9700 PAGE 2 OF 2 ©2008 BY R.J. CADILLAC