SYSTEM DESIGN:
GARBAGE DISPOSER IS NOT ALLOWED
DESIGN FLOW: 4 BEDROOMS ® 110 GPD = 440 GPD
USE A 440 GPD DESIGN FLOW
SEPTIC TANK: 440 GPD (2) = 880
USE A 1500 MIN. GAL. SEPTIC TANK
BOTTOM AREA ONLY:
13.5' (+/-) X 50.3'= 602 SF X (.74) = 446 GPD
USE A 602 SF LEACHING FIELD AS SHOWN
APPROVED
NOTES
1. DATUM IS NGVD29
2. MUNICIPAL WATER IS AVAILABLE
3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT.
MA
DATE BOARD OF HEALTH
4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS
TO BE AASHO H-12
5. PIPE JOINTS TO BE MADE WATERTIGHT.
6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH
310 CMR 15.000 (TITLE V.)
7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO
BE USED FOR LOT LINE STAKING OR ANY OTHER
PURPOSE.
8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC.
9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED
WITHOUT INSPECTION BY BOARD OF HEALTH AND
PERMISSION OBTAINED FROM BOARD OF HEALTH,
10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING
DIGSAFE (1-888-344-7233) AND VERIFYING THE
LOCATION OF ALL UNDERGROUND & OVERHEAD UTILITIES
PRIOR TO COMMENCEMENT OF WORK.
11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE
REMOVED 5' BENEATH AND AROUND THE PROPOSED
LEACHING FACILITY.
12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND
REMOVED OR PUMPED AND FILLED WITH CLEAN SAND.
13. NO"BASEMENT" ALLOWED. FLOODZONE RESISTANT
DESIGN REQUIRED (BY OTHERS). FINAL GRADING TO
BE IN ACCORDANCE WITH FEMA REGULATIONS AS SHOWN.
14. ALL RUN-OFF TO BE CONTAINED ON-SITE
DESIGN REQUIRED (BY OTHERS). FINAL GRADING TO
BE IN ACCORDANCE WITH FEMA REGULATIONS.
15. DRYWELLS (OR DRIP TRENCHES) SHALL BE INSTALLED
TO CONTAIN ROOF RUN-OFF.
16. CONTRACTOR TO COORDINATE ALL UTILITY DISCONNECTS
AND NEW SERVICES WITH APPROPRIATE VENDORS.
17. CONTRACTOR TO NOTE ORDER OF CONDITIONS COVERING
ANY WORK ON SITE TO BE ISSUED BY THE TOWN OF YARMOUTH
CONSERVATION COMMISSION. COPY OF ORDER TO BE ONSITE AND ALL
CONDITIONS AND SPECIAL CONDITIONS SHALL BE ADHERED TO.
*THE INSTALLER SHALL VERIFY THE
LOCATIONS OF ALL UTILITIES AND ALL
BUILDING SEWER OUTLETS AND
ELEVATIONS PRIOR TO INSTALLING ANY
PORTION OF SEPTIC SYSTEM T(
CRAWLSPACE SLAB 8.4 \
FLOOD VENTS WITHIN 12" GRADE
(GROUND AT EL. 8.3) REQ.
VENTS ON 2 SIDES REQ.
FLOOD VENT/FOUNDATION DESIGN
BY OTHERS. •;';
EXIST. DWELL. \
#361
ALL SYSTEM COMPONENTS SHALL BE MARKED
WITH MAGNETIC TAPE OR COMPARABLE MEANS
FOR FUTURE LOCATION. MARK CORNERS OF
LEACH FIELD WITH 24" #5 REBAR WITH SAFETY
CAP DRIVEN JUST BELOW GRADE EACH CORNER
OF LEACH FIELD.
FIRST FLOOR BLDG ELEV, 13.0t CONCRETE ACCESS COVERS TO WITHIN 6" OF FIN. GRADE / 4" DIA PERF. INSP. PORT
TOP FOUNDATION 12.0t LEACHING FIELD, 4" THRE.
10.7'
MINIMUM .75' OF COVER OVER PRECAST
PRECAST H-10
4"SCH40
9.1*
8.79'
DEPTH OF FLOW = 4'
INLET DEPTH = 10
OUTLET DEPTH - 14"
(2-% SLOPE)
FOUNDATION 15' . -.. SEPTIC TANK
��/
fs'O ,, ROP. RET.
'4p-- TW = -9.5'
(DESI FYI
PROP. 4 BR DWELLING -
FIRST FL ELEV. 13.0'
(CRAWLSPACE SLAB ELEV.
MIN. 8.2')
5' UNSUfTABLE SOIL REMOVAL/
LIMIT AROUND LEACHING FIELD
SITE PLAN
Scale: 1 "= 20'
NOTE: NO INCREASE IN TITLE 5 DESIGN FLOW, NOT "NEW CONSTRUCTION" UNDER TITLE 5. 0 o zo 3n an sn FFFT
VARIANCES REQUESTED UNDER MAXIMUM FEASIBLE COMPLIANCE:
LEACHING FIELD TO BE LOCATED 7.5' FROM LOT LINE (10' REQUIRED) VARIANCE OF 2.5' REQUESTED
LEACHING FIELD TO BE LOCATED 25' FROM DRAIN WHICH MAY INTERCEPT HIGH GROUNDWATER- 50' REQ. 25' VARIANCE REQUESTED, WALL/LINER PROVIDED
VARIANCE TO LOCAL BOARD OF HEALTH REGULATIONS -
SEPTIC TANK TO BE 75' FROM COASTAL BANK, 100' REQUIRED, 25' VARIANCE REQUESTED
LEACHING AREA TO BE 70.4' FROM COASTAL BANK, 100' REQUIRED, 29.6' VARIANCE REQUESTED
LICE # 09-130
2'0IRS
SE (nP) 4"0SCH40
PIPES LEVEL 1ST 2'
\8.54' 00000 0
0 0 0 0 0
e o o a o 0 0
eov000vov000 0
9.5± �P 8.40'
CLEAN
3/4"-1-1/2" DOUBLE WASHED
8.52' 8.35
8.25' LEVEL
D -BOX ACME DB -5 OR EQ.
BLOCK UP FOR 24• COVER TYP.
6" CRUSHED STONE OR MECHANICAL BLDG E PROFILE
COMPACTION. (15.221 [2])
55'
TIDALLY INF
(-Z-% SLOPE) (-!--7 SLOPE) LEACHING: USE A 602 SF LEACF
2' D' BOX 12' LEACHING
FACILITY
PROPOSED 4 BR SEPTIC SYSTEM TO
1a•
CONSIST OF 4 TITLE 5 COMPLIANT 1500
L
GALLON SEPTIC TANK, DBOX, AND A
BY S/T)
602 SF LEACH FIELD, BASE OF WHICH
TEE 1500 MIN. GAL H-10
IS 5' ABOVE HIGH GROUNDWATER.
FINAL GRADE OVER SAS TO BE ELEV.
a:
SEPTIC TANK ST TEE
SLOPE OF GROUND
71)
4' LIQ. LEVEL
5' MIN.UNSUITABLE
THEN SAND
SHOREY OR EQUAL cas BAFrTE
SOIL REMOVAL
°d
0000000000000000000000
0 0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 00
(2-% SLOPE)
FOUNDATION 15' . -.. SEPTIC TANK
��/
fs'O ,, ROP. RET.
'4p-- TW = -9.5'
(DESI FYI
PROP. 4 BR DWELLING -
FIRST FL ELEV. 13.0'
(CRAWLSPACE SLAB ELEV.
MIN. 8.2')
5' UNSUfTABLE SOIL REMOVAL/
LIMIT AROUND LEACHING FIELD
SITE PLAN
Scale: 1 "= 20'
NOTE: NO INCREASE IN TITLE 5 DESIGN FLOW, NOT "NEW CONSTRUCTION" UNDER TITLE 5. 0 o zo 3n an sn FFFT
VARIANCES REQUESTED UNDER MAXIMUM FEASIBLE COMPLIANCE:
LEACHING FIELD TO BE LOCATED 7.5' FROM LOT LINE (10' REQUIRED) VARIANCE OF 2.5' REQUESTED
LEACHING FIELD TO BE LOCATED 25' FROM DRAIN WHICH MAY INTERCEPT HIGH GROUNDWATER- 50' REQ. 25' VARIANCE REQUESTED, WALL/LINER PROVIDED
VARIANCE TO LOCAL BOARD OF HEALTH REGULATIONS -
SEPTIC TANK TO BE 75' FROM COASTAL BANK, 100' REQUIRED, 25' VARIANCE REQUESTED
LEACHING AREA TO BE 70.4' FROM COASTAL BANK, 100' REQUIRED, 29.6' VARIANCE REQUESTED
LICE # 09-130
2'0IRS
SE (nP) 4"0SCH40
PIPES LEVEL 1ST 2'
\8.54' 00000 0
0 0 0 0 0
e o o a o 0 0
eov000vov000 0
9.5± �P 8.40'
CLEAN
3/4"-1-1/2" DOUBLE WASHED
8.52' 8.35
8.25' LEVEL
D -BOX ACME DB -5 OR EQ.
BLOCK UP FOR 24• COVER TYP.
6" CRUSHED STONE OR MECHANICAL BLDG E PROFILE
COMPACTION. (15.221 [2])
55'
TIDALLY INF
(-Z-% SLOPE) (-!--7 SLOPE) LEACHING: USE A 602 SF LEACF
2' D' BOX 12' LEACHING
FACILITY
0 SAND AT BOTTOM OF
DED CAP TO WITHIN 3" OF FINISH GRADE 40 MIL LINER FROM ELEV. 8.4 TO ELEV. 4.4 MIN.
\ RETAINING WALL SCHEMATIC SHOWN, EXACT FASCADE
\\\ AND CONSTRUCTION BY OTHERS. TOP OF WALL HT. AS NOTED
[SHED GRADE- 4" LOAM & SEED 2% MIN, SLOPE OVER SYSTEM \
o
LEACHING FIELD o
PROPOSED 4 BR SEPTIC SYSTEM TO
A d:
CONSIST OF 4 TITLE 5 COMPLIANT 1500
L
GALLON SEPTIC TANK, DBOX, AND A
BY S/T)
602 SF LEACH FIELD, BASE OF WHICH
V
IS 5' ABOVE HIGH GROUNDWATER.
FINAL GRADE OVER SAS TO BE ELEV.
a:
10.5 -9.5' VARIES
0 SAND AT BOTTOM OF
DED CAP TO WITHIN 3" OF FINISH GRADE 40 MIL LINER FROM ELEV. 8.4 TO ELEV. 4.4 MIN.
\ RETAINING WALL SCHEMATIC SHOWN, EXACT FASCADE
\\\ AND CONSTRUCTION BY OTHERS. TOP OF WALL HT. AS NOTED
[SHED GRADE- 4" LOAM & SEED 2% MIN, SLOPE OVER SYSTEM \
o
LEACHING FIELD o
,.CAP ENDS
v
6"DEPTH �; MIN BELOW INV.
A d:
•p°,r+,-;.
0
8.00'
PROPOSED CONTOUR
BOTTOM o
PROPOSED SPOT EL.
3" LOAM
a:
3" LOAM
SLOPE OF GROUND
71)
THEN SAND
5' MIN.UNSUITABLE
THEN SAND
7.50'
SOIL REMOVAL
°d
24"
WHERE SPECIFIED.
•'
A LS
DEPTH PER SOIL LOGS
5.0'
00000
10YR 3/2
00000000000,
10YR 3/2
JENCED GROUNDWATER
_ 2.5'
NG FIELD 602 SF
X .74 = 445 GPD O.K.
TEST HOLE LOGS
ENGINEER: DANIEL A. OJALA PE, PLS SE1805
WITNESS: AMY VON HONE RS, CHO
DATE: JULY 1, 2009
PERC. RATE _ < 2 MIN/INCH___
CLASS SOILS P#
ELEV
D„
4
7.0' Q„
4
7.0'
FILL
PROPOSED CONTOUR
FILL
PROPOSED SPOT EL.
TH1
3" LOAM
TEST HOLE
3" LOAM
SLOPE OF GROUND
71)
THEN SAND
y41
THEN SAND
-W-
24"
-X-
24"
LOT LINE
A LS
POST LIGHT
A LS
27"
10YR 3/2
27"
10YR 3/2
B LS
B LS
42"
10YR 5/6
3.5' 42„
10YR 5/6
3.5'
C1
C1
PERC
BOTT. AT
52•, 24
GAL IN
9:30
< 2 MIN/INCH
M/C S
M/C S
GROUNDWATER DEPTH 56.4"
el. 2.3' BUT TIDALLY INFLUENCED
2.5 Y 7/3
7 EL. 2.3'
-
2.5 Y 7/3
SEE BELOW
120„
-3.0 120"
-3.0
NOTE: MONITORING WELL
OVER LUNAR CYCLE EL. 2.5
TIDALLY INFLUENCED- USE 2.5 NGVD29 AS ADJUSTED HIGH GROUNDWATER ELEVATION
4" DIA PERF. INSP. PORT TO SAND AT BOTTOM OF
LEACHING FIELD. 4" THREADED CAP, SCH40 PVC
THREADED CAP TO WITHIN 3" OF FINISH GRADE
2% MIN. FINISH GRADE
LOAM AND
SEED
MIRAFI 140N FABRIC
OR 2" PEASTONE
5' MIN.-
�j 3/4" TO 1 i 1/2" DOUBLE
ADJ. _ WASHED STONE (NO FINES)
GROUNDWATER
5' MIN.UNSUITABLE CROSS SECTION VIEW
SOIL REMOVAL
WHERE SPECIFIED
DEPTH PER SOIL LOGS
LEACHING FIELD TYPICAL DETAIL
NOT TO SCALE
-T GIST R v ! ND ss+
1�) AL
DATE DANIEL A. OJALA, P.E.DANIEL A. OJALA, P.E., P.L.S.
off 508-362-4541
fax 508-362-9880
downcape.com
down cope engineering, im.
civil engineers
land surveyors
939 Main Street ( Rte 6A)
YARMOUTHPORT MA 02675
e
Lewis Bay
h
°dio
Road
gond
c� (0 0
° Nantucket
Sound
LOCUS MAP
SCALE 1"=2000'±
ASSESSORS MAP 14 PARCEL 3
DATUM: NGVD
LOCUS IS WITHIN FEMA FLOOD ZONE B &
Al2 ELEV. 10 AS SHOWN ON COMMUNITY
PANEL #250015 0005 D DATED JULY 2,
1992
(NOTE: ELEVATIONS, BASED ON NGVD,
INDICATE ENTIRE SITE IS WITHIN THE 100
YEAR FLOOD ELEVATION)
WETLAND RESOURCE AREAS FLAGGED BY
LEC ENVIRONMENTAL CONSULTANTS, INC.
ZONING SUMMARY
ZONING DISTRICT: R-25
MIN. LOT SIZE 25,000 S.F.
MIN. FRONT SETBACK 30'
MIN. SIDE SETBACK 15'
MIN. REAR SETBACK 20'
MAX. LOT COVERAGE: 25%
UPLAND AREA (TO C. BANK) = 12745 SF
SITE IS LOCATED WITHIN AP DISTRICT
REFERENCES
CTF 139728
LCP 14426H, LOT 80
LEGEND
-- 99--
EXISTING CONTOUR
X 99.7
EXIST. SPOT ELEV.
99
PROPOSED CONTOUR
098.41
PROPOSED SPOT EL.
TH1
TEST HOLE
21
SLOPE OF GROUND
71)
UTILITY POLE
y41
FIRE HYDRANT
-W-
WATER LINE
-X-
FENCE LINE
LOT LINE
POST LIGHT
NOTE NOT ALL SYMBOLS MAY APPEAR IN DRAWING
SITE PLAN
SHOWING PROPOSED DWELLING
AT
355 GREAT ISLAND ROAD
WEST YARMOUTH
PREPARED FOR
B. RODOALPH &
M. MICOZZI
JUNE 12, 2009
REV. JULY 1, 2009 (TH LOGS ETC.)
Scale: 1"= 20'
0 10 20 30 40 50 FEET